Rheem 3 Ton R-454B Commercial Packaged Air Conditioner — RACCYB036ACT000AAAA0
The Rheem RACCYB036ACT000AAAA0 is a 3-ton Commercial Classic Series packaged air conditioner that arrives factory-charged with low-GWP R-454B refrigerant and wired for 208/230V three-phase power. Rated at 34,200 BTU/h of AHRI net cooling and 10.6 EER2 / 13.4 SEER2, this self-contained rooftop or slab-mount unit pairs a single-stage scroll compressor with microchannel indoor and outdoor coils and convertible downflow or horizontal airflow, making it a straightforward cooling-only choice for small storefronts, offices, and light-commercial spaces that already have three-phase service at the building.
Is a 3-Ton Package Unit the Right Size?
This 3-ton unit sits near the entry of Rheem's small-commercial RACC line and is matched to spaces with a cooling load in the neighborhood of 34,000 to 36,000 BTU/h — often roughly 1,200 to 1,800 sq ft of conditioned light-commercial space, depending on the building. Square footage alone is only a starting point, though; two rooms of the same size can carry very different loads.
Insulation levels, roof and wall exposure, ceiling height, the number of people in the space, lighting and plug loads, outdoor design temperature, and ventilation air all change the calculated load. A sun-exposed corner suite with lots of glass and foot traffic can need this full 3 tons where a shaded, well-insulated back office of the same size would not. Sizing from a Manual N / Manual J style load calculation rather than area alone keeps the compressor off short cycles and protects comfort and humidity control.
Ideal for: Small retail storefronts, individual office suites, bank branches, medical and dental offices, modular classrooms, small worship spaces, and light-commercial tenant improvements served by 208/230V three-phase power.
Need more capacity? Step up to the 4-Ton Rheem R-454B 208/230V 3-Phase Package Unit (RACCYB048ACT000AAAA0) for larger zones that need more cooling capacity.
Recommended applications are general guidelines only. Actual capacity requirements depend on insulation, ventilation, occupancy, solar gain, ceiling height, and local design temperatures. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Model Number | RACCYB036ACT000AAAA0 |
|---|---|
| Product Type | Commercial Classic Series Straight-Air (Cooling-Only) Packaged Air Conditioner |
| Nominal Capacity | 3 Tons — 36,000 BTU/h (34,200 BTU/h AHRI net cooling) |
| Rated Efficiency | 10.6 EER2 / 13.4 SEER2 |
| Refrigerant | R-454B (A2L, factory charged — approx. 72 oz) |
| Compressor | Single-stage scroll compressor |
| Nominal Airflow | 1,200 CFM — convertible downflow or horizontal |
| Electrical | 208/230V, 3-Phase, 60 Hz |
| Minimum Circuit Ampacity | 24 A |
| Max Overcurrent Protection | 35 A |
| Manufacturer Warranty | 5-Year Compressor / 1-Year Parts (Commercial) |
The RACCYB036ACT000AAAA0 ships as one factory-assembled, wired, and run-tested cabinet, so there is no field refrigerant line set to braze — it arrives charged with R-454B and ready to set, connect power and ducting, and commission. For curbed rooftop installs, pair it with the matching 3–6 Ton Rheem 14 in. roof curb (RXKG-DCC14). Browse more Rheem equipment or the full packaged air conditioner lineup for related sizes and voltages.
Unit Features
Cooling, Compressor & Coils
- Single-stage scroll compressor factory-charged with low-GWP R-454B refrigerant
- MicroChannel outdoor condenser coil and MicroChannel indoor evaporator coil for efficient heat transfer and reduced refrigerant charge
- TXV (thermostatic expansion valve) refrigerant metering with a solid-core liquid-line filter drier
- Factory-installed A2L refrigerant leak detection system with automatic mitigation
- Rated 10.6 EER2 / 13.4 SEER2 at 36,000 BTU/h nominal (34,200 BTU/h AHRI net) cooling
- High- and low-pressure protection with built-in Smart Logic and internal compressor overload
- Cooling operation to 125°F ambient; ships wired and run-tested
- 18-gauge galvanized cabinet with forkable base rails and gasket-protected panels
Airflow, Controls & Serviceability
- Convertible airflow — vertical downflow or horizontal side-flow — delivering 1,200 nominal CFM
- Direct-drive ECM indoor blower with multiple selectable speed taps
- PlusOne ServiceSmart access: Qwik-Change Flex-Fit filter rack, Qwik-Slide blower assembly, and Qwik-Clean composite drain pan
- PlusOne Diagnostics with dual 7-segment LED display and standard Modbus interface
- Overflow condensate sensor and external lockable gauge ports
- Ships with four disposable 2 x 16 x 16 in. filters; MERV 8 and MERV 13 filters available as field accessories
- 208/230V, 3-Phase, 60 Hz power: 24 A minimum circuit ampacity, 35 A maximum overcurrent protection, compressor RLA 12.8 A
- Field-installed accessories include economizers, roof curbs, hail guards, disconnects, and low-ambient control
Specifications & Manuals
Product documentation includes RACC series technical specifications, installation instructions, and warranty information to assist with equipment selection, installation, and service. This unit carries a Rheem limited warranty; see the warranty document above for full coverage terms and conditions.
Frequently Asked Questions
What size space will the RACCYB036ACT000AAAA0 cool?
It is matched to commercial cooling loads around 36,000 BTU/h (34,200 BTU/h AHRI net), which often lands near roughly 1,200 to 1,800 sq ft of light-commercial space. Because occupancy, ventilation, glazing, and internal heat gain move the real load, confirm the size with a commercial load calculation rather than floor area alone.
What power does the RACCYB036ACT000AAAA0 require?
This model is wired for 208/230V, 3-Phase, 60 Hz. It needs a minimum circuit ampacity of 24 A and a maximum overcurrent protection device of 35 A, with a compressor RLA of 12.8 A. If your building distributes power at 460V instead, order the 460V three-phase 3-ton RACCYB036ADT version of this unit.
Is this unit charged with R-454B, and does it have leak detection?
Yes. The RACCYB036ACT000AAAA0 is factory-charged with low-GWP R-454B (an A2L refrigerant) and includes a factory-installed refrigerant leak detection system that triggers a fault and mitigation sequence if a leak is sensed. Refrigerant charge is approximately 72 oz.
Can this package unit be installed downflow and horizontal?
Yes. Airflow is field-convertible between vertical downflow (for roof-curb installations) and horizontal side-flow, so the same unit works on a curbed rooftop opening or a slab with ducted side connections. A matching 14 in. Rheem roof curb (RXKG-DCC14) is available for 3–6 ton units.
Does this unit provide heat?
This is a cooling-only (straight-air) package air conditioner. Electric resistance heater kits are available as field- or factory-installed accessories on the RACC platform; if you need heating built in, a gas/electric or heat-pump package unit is the better starting point.
Does the RACC package unit include a warranty?
Yes. Rheem provides a limited warranty on the RACC series — a 5-year compressor and 1-year parts limited warranty for commercial applications (longer terms may apply to residential applications on 3–5 ton models with registration). See the Rheem Limited Warranty document above for full terms and conditions.
RACCYB 3-6 Ton Straight Cool Package Installation Instructions
RACCYB 3-6 Ton Straight Cool Package Technical Specifications