3 Ton Rheem 14.3 SEER2 R454B Single Stage Central System RA14AY36AJ1NA, RH1AY3617STANNJ
This 3 ton Rheem Endeavor® Line Classic® system pairs the RA14AY36AJ1NA condenser with the RH1AY3617STANNJ single-stage-airflow air handler, AHRI certified at 14.3 SEER2 (#217232212). It's one of the most popular residential sizes, delivering 36,000 BTU/h on low-GWP R-454B refrigerant. The RA14AY36 keeps a low 25" profile, and the air handler includes Rheem's PlusOne® Refrigerant Detection System™. It's cooling only, with Rheem electric heat strips up to 15 kW offered.
Is a 3 Ton Air Conditioning System the Right Size?
A 3 ton system provides 36,000 BTU/h of nominal cooling. It's often used in 3-bedroom homes around 1,500–1,800 sq. ft. as a general guide. Hot, humid climates and homes with lots of glass may need more capacity for the same space.
At 3 tons, return air and duct sizing matter as much as the equipment. Undersized returns can starve the air handler of airflow. Pair a Manual J load calculation with a quick duct check to be sure the system performs as rated.
Ideal for: 3-bedroom single-family homes, larger townhomes and rental homes.
Need more capacity? Step up to the 3.5 Ton Rheem 14.3 SEER2 R454B Single Stage Central System RA14AY42AJ1NA, RH1AY4821STANNJ for a larger load.
Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condensing Unit | RA14AY36AJ1NA — 3 Ton Rheem Classic R454B Air Conditioner |
|---|---|
| Indoor Air Handler | RH1AY3617STANNJ Single-Stage Airflow Multipoise Air Handler (17.5" Wide) |
| Application | Cooling-Only Central Air Split System (Electric Heat Kit Optional) |
| Refrigerant | R-454B (Low-GWP A2L Refrigerant) |
| Compressor | Single-Stage Scroll Compressor |
| Metering Device | Factory-Installed Expansion Valve on Indoor Coil (TXV) |
| Electrical | 208/230V, Single Phase, 60 Hz Condensing Unit — 18 MCA / 30A Max Overcurrent |
| Air Handler Electrical | 208/240V, Single Phase — 3 MCA / 15A Max Overcurrent (No Heat Kit) |
The RA14AY36AJ1NA condenser is just 25" tall on a 33.75" x 33.75" base and weighs 186 lbs (operating), with a 71 dBA sound rating. The RH1AY3617STANNJ air handler is 17.5" wide and 42.5" tall and weighs 96 lbs, with a 1/2 HP motor. For comparison, see the 3 ton Rheem Select WA14AY36AJ1NA, RH1AY3617STANNJ system.
Condensing Unit & Air Handler Features
RA14AY36AJ1NA Outdoor Condensing Unit
- 36,000 BTU/h nominal cooling capacity
- Single-stage scroll compressor
- 71 dBA weighted sound power rating
- 7 mm copper tube condenser coil uses less refrigerant
- 116 oz. factory R-454B charge for 15 ft. of line set
- 24" two-blade Swept Wing fan with 1/6 HP motor
- 3/8" liquid and 3/4" suction front-seating service valves
- PlusOne® Expanded Valve Space and Triple Service Access
- Composite base pan, powder-coated paint and rust-resistant screws
- 10-year conditional parts limited warranty (registration required)
RH1AY3617STANNJ Single-Stage Air Handler
- Single-stage airflow with a constant torque (ECM) motor
- 1/2 HP multi-speed motor, 1,000/1,200 CFM nominal airflow
- PlusOne® Refrigerant Detection System™ with factory-installed A2L sensor
- Aluminum fins bonded to internally grooved aluminum tubing
- 4-way convertible: upflow, downflow, horizontal left or right
- 1.0" foil-faced cabinet insulation for quieter operation
- Cabinet air leakage under 2% at 1" H₂O (ASHRAE 193)
- Slide-out blower and factory leak-tested coil
- Expansion valve on indoor coil for AC or heat pump use
- Field-installed heater kits up to 15 kW with UL/cUL-listed breakers
Specifications & Manuals
Documentation includes RA14AY electrical, sound, dimensional and line-size data, condenser and air handler installation instructions, the RA14AY brochure, RH1AY airflow and heater tables and the Rheem limited warranty.
Frequently Asked Questions
What fan does the RA14AY36AJ1NA use?
Rheem lists a 24" two-blade Swept Wing fan with a 1/6 HP motor, moving 2,760 CFM across the outdoor coil.
How much R-454B is factory charged in the RA14AY36AJ1NA?
Rheem lists a 116 oz. factory charge, sized for 15 ft. of line set. Longer runs need added refrigerant per the installation instructions.
How does this compare to the Rheem Select 3 ton RH1AY system?
The Rheem Select WA14AY36AJ1NA, RH1AY3617STANNJ system uses the same air handler with a Select-series condenser. This RA14AY36 version adds Classic cabinet features like Triple Service Access and a composite base pan.
Is there a two-stage airflow version of this 3 ton system?
Yes. The 3 ton RA14AY36AJ1NA, RH2TY3617STANNJ system pairs the same condenser with a two-stage-airflow RH2TY air handler and a higher SEER2 match.
What is the no-heat circuit requirement for the RH1AY3617STANNJ?
Rheem lists 2.4 motor amps, a 3.0 amp minimum circuit ampacity and 15 amp maximum overcurrent protection at 208/240V without electric heat. Heat kits change these values.
Can the RA14AY36AJ1NA run in cold weather for year-round cooling?
With Rheem's RXAD-A08 low ambient kit, yes. A compressor crankcase heater (44-101884-08) is also listed as an accessory for the RA14AY36.
RA14AY Technical Specifications
RA14AY Installation Instructions
RA14AY Brochure
RH1AY Technical Specifications
RH1AY Installation Instructions
Rheem Warranty Certificate