decor decor

Summary

Product #179371: $4,225.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 41939 / 3 Ton Rheem Two Stage R454B Air Handler RH2TY3617STANNJ (179307) -- 1
  • 41962 / 3 Ton Rheem Two Stage R454B Heat Pump Condenser RP15AY36AJ2NA (179330) -- 1
4225
$4,225.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
RP15AY36AJ2NA, RH2TY3617STANNJ | Service-Friendly 3 Ton Two-Stage Heat Pump for Family Homes

3 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY36AJ2NA, RH2TY3617STANNJ

· SKU 179371 · AHRI 215415461 · Split System
SEER2
15.2
Capacity
36,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,229.00

Sale price:

$4,225.00
You save $1,004.00!
  • SKU: 179371
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • SEER2:
    15.2
  • Product Type:
    Split System
  • Tonnage:
    3
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    17.5"
  • AHRI Number:
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Rheem Endeavor RH1PZ, RH2TZ, RXBH-1724B05J-1, WRX0502I
  • 7.2 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B07J-1, WRX0752I
  • 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I
  • 15 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RH1PY, RH2TY, RH2VY, RXBH-1724A15J-1, WRX1502BI
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • Honeywell T6 Pro Thermostat 3H/2C Programmable TH6320U2008
  • ProStat 7-Day Programmable Digital Thermostat 3H/2C PRS6320
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Honeywell T10 Pro Smart Wi-Fi Touchsrceen Thermostat 3H/2C Programmable w/ Sensor, THX321WFS2001W
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 3 Ton Rheem Two Stage R454B Air Handler RH2TY3617STANNJ
  • 3 Ton Rheem 15 SEER2 Two Stage R454B Heat Pump Condenser RP15AY36AJ2NA
Adding to cart… The item has been added

3 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY36AJ2NA, RH2TY3617STANNJ

Designed with service technicians in mind, the RP15AY36AJ2NA two-stage heat pump features Rheem's PlusOne® Expanded Valve Space and Triple Service Access, and this system pairs it with the RH2TY3617STANNJ air handler for 3 tons of R-454B heating and cooling. Rated 15.2 SEER2 under AHRI #215415461, it is a dependable fit for family homes, two-story houses, and contractors who want a system that is quick to install and easy to maintain.

Is a 3 Ton Heat Pump System the Right Size?

Rheem rates this match at 34,200 BTU/h of cooling and 33,200 BTU/h of heating at 47°F. Three tons is a workhorse size for family homes with several bedrooms, open kitchens and living areas, or upstairs and downstairs space on one duct system.

Two-story homes, bonus rooms over garages, and large expanses of glass can push the load past what square footage suggests, while new windows or added insulation can bring it down. A load calculation keeps the system from short-cycling or running nonstop, and two-stage operation helps it stay comfortable across that range.

Ideal for: Family homes with three to four bedrooms, two-story houses on one system, and replacement of an existing 3 ton heat pump.

Need more capacity? Step up to the 3.5 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY42AJ2NA, RH2TY4821STANNJ for larger homes and higher loads.

Recommended system sizes are general guidelines only. Actual heating and cooling requirements depend on insulation, climate, windows, ductwork, ceiling height, and occupancy. A Manual J load calculation is the best way to confirm sizing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump RP15AY36AJ2NA — 3 Ton R-454B Two-Stage Heat Pump
Indoor Air Handler RH2TY3617STANNJ — 2.5-3 Ton Two-Stage Multipoise Air Handler with TXV
System Rating 15.2 SEER2, 11.7 EER2, 7.8 HSPF2, 34,200 BTU/h Cooling, AHRI #215415461
Refrigerant R-454B (A2L, Low GWP)
Compressor Two-Stage Scroll Compressor
Defrost Demand Defrost Control
Electrical 208/230V, Single Phase, 60 Hz Heat Pump — MCA 20 A, Max Breaker 30 A
Air Handler Electrical 208-240V, Single Phase — 1/2 HP Constant Torque Motor, 17.5" Cabinet

The RP15AY36AJ2NA uses a 39" tall, 35-3/4" square cabinet, while the RH2TY3617STANNJ stays at a 17.5" width, now running at its full 3 ton rating. The air handler accepts up to a 15 kW breakered Rheem heat strip on this listing. Pair it with a copper line set, a sturdy condenser pad, and a two-stage programmable thermostat.

Heat Pump & Air Handler Features

RP15AY36AJ2NA Outdoor Heat Pump

  • Two-stage scroll compressor (15 RLA, 90 LRA)
  • PlusOne® Expanded Valve Space: 3-4-5 inch service valve layout
  • PlusOne® Triple Service Access with removable corner and louver panels
  • Two-screw control box access
  • Quick-release louver panels with no fasteners along the bottom
  • Demand defrost control
  • PlusOne® Refrigerant Detection System
  • 88 oz R-454B factory charge
  • 39" H x 35-3/4" W x 35-3/4" L cabinet, 214 lbs
  • Service trays and QR code for quick reference

RH2TY3617STANNJ Multi-Position Air Handler

  • Full 3 ton rating in a 17-1/2" cabinet
  • 1/2 HP two-stage constant torque motor
  • Factory TXV and factory-installed A2L sensor
  • 4-way convertible design
  • Rugged steel cabinet with pre-painted finish
  • 1" foil-faced insulation
  • Front refrigerant and drain connections
  • Coil factory leak tested
  • Supply duct flanges included
  • Accepts heat strips up to 15 kW breakered on this listing

Specifications & Manuals

Documentation includes RP15AY 3 ton electrical and line sizing data, the installation instructions with two-stage thermostat wiring, RH2TY airflow tables, and Rheem warranty information.

Frequently Asked Questions

What size home is the 3 ton RP15AY36AJ2NA system designed for?

It suits homes with a load near 36,000 BTU/h, often family homes with three to four bedrooms or two-story houses on a single system. Confirm with a load calculation.

Does the 3 ton system need a larger circuit than the 2.5 ton?

No. Rheem lists the same 20 A minimum circuit ampacity and 30 A maximum overcurrent protection for both the RP15AY36AJ2NA and the RP15AY30AJ2NA.

What makes the RP15AY36AJ2NA easier to service?

Rheem's PlusOne® Expanded Valve Space gives at least 27 sq. in. of working area around the valves, and PlusOne® Triple Service Access opens a 15" wide corner with only two fasteners.

How much heating does the 3 ton system provide at 17°F?

Rheem's tested data lists 22,200 BTU/h of heating at 17°F and 33,200 BTU/h at 47°F for this match.

Can I use a 15 kW heat strip with the RH2TY3617STANNJ?

Yes. This listing offers a 15 kW breakered heat strip (RXBH-1724A15J-1) as well as 5, 8, and 10 kW options.

What line set does the 3 ton RP15AY36AJ2NA use?

The unit has a 3/8" liquid and 3/4" suction valve. Rheem's line size table allows a 3/4" or 7/8" suction line depending on length; this listing offers 3/4" x 3/8" kits.

Customer Review