2.5 Ton Rheem 14.3 SEER2 R-454B Two Stage Heat Pump System RP14AY30AJ2NA, RH2TY3617STANNJ
This 30,000 BTU Rheem heat pump package moves up to the RH2TY3617STANNJ air handler, a three-ton-class coil in a 17.5 inch cabinet, paired with the two-stage RP14AY30AJ2NA outdoor unit. The combination is deliberately coil-heavy: more evaporator face area with a 2.5 ton compressor produces a lower sensible heat ratio, which is exactly what a humid climate needs. Homeowners get the dehumidification benefit without giving up the narrow closet footprint.
Is a 2.5 Ton Heat Pump System the Right Size?
A 2.5 ton system covers roughly 1,100 to 1,500 square feet in most of the Sun Belt. It is a frequent answer for three-bedroom ranch homes, mid-size townhouses and 1990s-era tract houses that have had attic insulation or windows upgraded since the original system was installed.
This capacity is also where many homes sit between two nominal sizes. When a Manual J calculation lands between 24,000 and 30,000 BTU, the 2.5 ton two-stage unit is usually the safer pick, because low stage covers the lighter part of the season without the short cycling that an oversized single-stage unit produces. Verify that the existing duct system can carry the airflow before upsizing from a 2 ton.
Ideal for: Three-bedroom ranch homes, larger townhomes, renovated tract houses, and open-plan homes in the 1,100 to 1,500 square foot range.
Need more capacity? Step up to the 3 Ton Rheem RP14AY36AJ2NA, RH2TY3617STANNJ Heat Pump System, which uses the identical air handler with a larger outdoor unit.
Recommended capacity ranges are general guidelines only. Actual system requirements depend on insulation, window area, duct design, air infiltration, and local climate. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | RP14AY30AJ2NA — 2.5 Ton / 30,000 BTU Two-Stage Heat Pump |
|---|---|
| Indoor Air Handler | RH2TY3617STANNJ — 17.5 in. Wide Multiposition Air Handler |
| Application | Residential Split System Heat Pump, Heating and Cooling |
| Refrigerant | R-454B Low GWP (A2L) |
| Compressor | Two-Stage Scroll |
| Rated Efficiency | 14.3 SEER2 / 9.0 EER2 / 7.5 HSPF2 (Region IV) |
| AHRI Reference | 214568766 |
| Condenser Electrical | 208/230V, Single Phase, 60 Hz — 20 MCA / 30 A Max Fuse or Breaker |
| Air Handler Electrical | 208/240V, Single Phase, 60 Hz |
| Line Set Connections | 3/8 in. Liquid, 3/4 in. Vapor |
The RH2TY3617STANNJ steps the blower up to a larger constant-torque ECM motor than the 2417 cabinet uses, so it has the static pressure headroom for longer duct runs and higher-MERV filtration. Mount the outdoor unit on a 40 x 40 Cladlite hurricane condenser pad to keep it level and above standing water.
Condenser & Air Handler Features
RP14AY30AJ2NA Outdoor Heat Pump
- 30,000 BTU two-stage scroll compressor with independent high and low capacity
- Low stage carries mild-weather load for longer cycles and steadier room temperatures
- Gravity-assisted inverted reversing valve reduces joint stress during defrost cycles
- 27 square inch minimum service valve working area from PlusOne Expanded Valve Space
- Removable two-fastener corner panel opens a 15 in. wide diagnostic and repair area
- One-box PlusOne Refrigerant Detection System with integrated A2L sensor
- Outdoor unit operation pauses automatically if excess refrigerant is sensed
- Louvered coil guard protects the condenser from yard debris and string trimmers
- R-454B platform meets the EPA's 2025 GWP limit of 700 for residential HVAC
- 20 amp minimum circuit ampacity, 30 amp maximum overcurrent protection
RH2TY3617STANNJ Air Handler
- Three-ton-class coil in a 17.5 in. wide cabinet for high capacity in a narrow closet
- Larger constant-torque ECM blower than the 2417 cabinet for added external static capability
- Extra coil face area with a 2.5 ton compressor improves latent moisture removal
- Convertible to upflow, downflow, horizontal left or horizontal right without a conversion kit
- Aluminum fin and internally grooved aluminum tube coil construction
- Foil-faced 1.0 in. insulation controls sweating and blower noise
- Under 2 percent cabinet leakage at 1 in. H2O, tested to ASHRAE Standard 193
- Accepts higher-capacity RXBH electric heat kits than the 17.5 in. two-ton cabinet
- Factory-provided knockouts simplify electrical, condensate and line set routing
- Integrated A2L refrigerant detection wired to shut down the system on a leak event
Specifications & Manuals
The documents above cover equipment selection through startup: technical specifications with capacity and airflow tables, submittal sheets for dimensions and electrical data, installation instructions for both the condenser and the air handler, the RP14AY product brochure, and Rheem warranty terms. The RH2TY documents also contain the electric heat kit selection tables.
Frequently Asked Questions
Is 2.5 tons enough for a 1,400 square foot house?
In most cases yes, provided the attic is reasonably insulated and the ductwork is sealed. Homes with heavy west-facing glass, cathedral ceilings or leaky ducts may calculate closer to 3 tons, so run the load before deciding.
Why does this system use the RH2TY3617STANNJ instead of the 2417 cabinet?
The 3617 is the next coil size up and is rated for 2.5 to 3 tons. Rheem matches it to the 30,000 BTU condenser so the evaporator is generously sized, which lowers coil temperature and pulls more humidity out of the supply air.
What electrical service does the RP14AY30AJ2NA need?
208/230V single phase, 60 Hz, with a 20 amp minimum circuit ampacity and 30 amp maximum overcurrent protection. The air handler and any electric heat kit require a separate circuit sized to the kit.
Does the larger coil really improve dehumidification?
Yes. A bigger evaporator paired with a smaller compressor lowers the sensible heat ratio, meaning a larger share of the system's work goes into removing moisture instead of dropping air temperature. Combined with low-stage run time, it keeps indoor relative humidity down.
Can the air handler be installed horizontally in an attic?
Yes. The RH2TY3617STANNJ converts to horizontal left or horizontal right in the field. Attic installations require an auxiliary drain pan with a float switch and adequate service access per local code and the installation instructions.
How does the RP14AY compare with the RP15AY at this capacity?
The RP15AY is the next efficiency tier in Rheem's Endeavor Line and carries a higher SEER2 rating with a larger outdoor coil and footprint. The two share a common installation manual, so the differences are easy to compare side by side. Browse all Rheem heating and cooling equipment to weigh the tiers.
RP14AY Technical Specifications
RP14AY Brochure
RP14AY Installation Instructions
RP14AY Submittal Sheet
RH2TY Technical Specifications
RH2TY Installation Instructions
RH2TY Submittal Sheet
Rheem Warranty Certificate