Product #179370: $3,970.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 41939 / 3 Ton Rheem Two Stage R454B Air Handler RH2TY3617STANNJ (179307) -- 1
  • 42004 / 2.5 Ton Rheem R454B Two Stage Heat Pump Condenser RP15AY30AJ2NA (179376) -- 1
3970
$3,970.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
RP15AY30AJ2NA, RH2TY3617STANNJ | 2.5 Ton Two-Stage Comfort in a Slim 17.5" Air Handler

2.5 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY30AJ2NA, RH2TY3617STANNJ

· SKU 179370 · AHRI 215486998 · Split System
SEER2
15.2
Capacity
30,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $4,904.00

Sale price:

$3,970.00
You save $934.00!
  • SKU: 179370
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • SEER2:
    15.2
  • Product Type:
    Split System
  • Tonnage:
    2.5
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    17.5"
  • AHRI Number:
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Rheem Endeavor RH1PZ, RH2TZ, RXBH-1724B05J-1, WRX0502I
  • 7.2 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B07J-1, WRX0752I
  • 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • Honeywell T6 Pro Thermostat 3H/2C Programmable TH6320U2008
  • ProStat 7-Day Programmable Digital Thermostat 3H/2C PRS6320
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Honeywell T10 Pro Smart Wi-Fi Touchsrceen Thermostat 3H/2C Programmable w/ Sensor, THX321WFS2001W
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 3 Ton Rheem Two Stage R454B Air Handler RH2TY3617STANNJ
  • 2.5 Ton Rheem 15 SEER2 R454B Two Stage Heat Pump Condenser RP15AY30AJ2NA
Adding to cart… The item has been added

2.5 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY30AJ2NA, RH2TY3617STANNJ

This 2.5 ton Rheem heat pump system pairs the RP15AY30AJ2NA outdoor unit with the RH2TY3617STANNJ air handler, a two-stage blower that keeps a slim 17.5" cabinet width. Rated 15.2 SEER2 under AHRI #215486998 on R-454B refrigerant, it suits mid-size homes where the indoor unit has to fit an existing narrow closet or return opening but the owner still wants the comfort of two-stage heating and cooling.

Is a 2.5 Ton Heat Pump System the Right Size?

Rheem rates this combination at 28,600 BTU/h of cooling and the same 28,600 BTU/h of heating at 47°F. That makes it a common choice for three-bedroom houses and open-concept single-story layouts where 2 tons falls short and 3 tons would be more than needed.

Ductwork matters as much as tonnage here. Undersized or leaky ducts can keep a 2.5 ton system from reaching its rated airflow, and large west-facing windows or vaulted ceilings can push the load higher than expected. A room-by-room load calculation confirms both the equipment size and the duct design.

Ideal for: Three-bedroom homes, open single-story floor plans, and replacements where the air handler must stay in a 17.5" wide space.

Need more capacity? Step up to the 3 Ton Rheem 15.2 SEER2 R454B Two Stage Heat Pump System RP15AY36AJ2NA, RH2TY3617STANNJ, which uses the same air handler with a larger outdoor unit.

Recommended system sizes are general guidelines only. Actual heating and cooling requirements depend on insulation, climate, windows, ductwork, ceiling height, and occupancy. A Manual J load calculation is the best way to confirm sizing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump RP15AY30AJ2NA — 2.5 Ton R-454B Two-Stage Heat Pump
Indoor Air Handler RH2TY3617STANNJ — 2.5-3 Ton Two-Stage Multipoise Air Handler with TXV
System Rating 15.2 SEER2, 11.7 EER2, 7.8 HSPF2, 28,600 BTU/h Cooling, AHRI #215486998
Refrigerant R-454B (A2L, Low GWP)
Compressor Two-Stage Scroll Compressor
Defrost Demand Defrost Control
Electrical 208/230V, Single Phase, 60 Hz Heat Pump — MCA 20 A, Max Breaker 30 A
Air Handler Electrical 208-240V, Single Phase — 1/2 HP Constant Torque Motor, 17.5" Cabinet

The RH2TY3617STANNJ steps up to a 1/2 HP motor while keeping the same 17.5" width as the 2 ton air handler, so it can often drop into the same closet. Outdoors, the RP15AY30AJ2NA moves to a larger 35" tall cabinet with a 24" three-blade fan. Complete the install with a copper line set, a Rheem heat strip, and a properly sized air filter.

Heat Pump & Air Handler Features

RP15AY30AJ2NA Outdoor Heat Pump

  • Two-stage scroll compressor (15 RLA)
  • 24" three-blade condenser fan, 1/5 HP motor
  • 7 mm copper tube single-row coil
  • Demand defrost control
  • Inverted reversing valve for faster heat transfer
  • PlusOne® Refrigerant Detection System
  • 85 oz R-454B factory charge for 15 feet of line
  • Long-line capability up to 200 feet actual length
  • 35" H x 33-3/4" W x 33-3/4" L cabinet, 202 lbs
  • 73 dBA weighted sound power rating

RH2TY3617STANNJ Multi-Position Air Handler

  • Slim 17-1/2" wide cabinet, 42-1/2" tall
  • 1/2 HP two-stage constant torque motor
  • Rated for 2.5 and 3 ton outdoor units
  • Factory TXV for heat pump operation
  • Internally grooved aluminum tube coil for corrosion resistance
  • Upflow, downflow, or horizontal installation
  • 1" foil-faced insulation
  • Less than 2% cabinet air leakage at 1" H2O
  • Slide-out blower assembly
  • Heat strip options of 5, 8, or 10 kW on this listing

Specifications & Manuals

The RP15AY specifications include 2.5 ton dimensions, line size tables, and performance data, while the RH2TY literature covers 17.5" cabinet airflow and heater kit details.

Frequently Asked Questions

What homes are a good match for the 2.5 ton RP15AY30AJ2NA heat pump?

Three-bedroom houses and open single-story layouts with a load near 30,000 BTU/h are typical. A load calculation will confirm whether 2.5 tons is right for your home.

Why does this 2.5 ton system use the RH2TY3617STANNJ air handler?

The RH2TY3617STANNJ is Rheem's 2.5 to 3 ton air handler. It keeps a 17.5" cabinet width with a 1/2 HP two-stage motor and is certified with the RP15AY30AJ2NA under AHRI #215486998.

How is the RP15AY30AJ2NA cabinet different from the 2 ton model?

It is larger: 35" tall and 33-3/4" square versus 25" tall and 29-3/4" square, with a 24" three-blade fan. It weighs 202 lbs compared to 150 lbs.

What heat strips are offered for the 2.5 ton system?

This listing offers 5, 8, and 10 kW Rheem heat strips. The right size depends on your climate and how much backup heat your home needs.

How long can the line set be on the RP15AY30AJ2NA?

Rheem allows up to 200 feet of actual line length and 250 feet equivalent length. Longer runs may need long-line accessories and added charge, as detailed in the installation instructions.

Does the RP15AY30AJ2NA use demand defrost?

Yes. The RP15AY series uses a demand defrost control that starts defrost based on operating conditions, which helps avoid unnecessary defrost cycles.

Customer Review