2 Ton Goodman R32 Ceiling Mount Pancake Air Handler with 5 kW Heat Strip, ACST24LU1305AA
The Goodman ACST24LU1305AA gives you 2 tons (24,000 BTU/h nominal) of R-32 cooling in a 6½"-tall ceiling mount cabinet, with a 5 kW heat strip installed at the factory. It's the cooling-first choice in the 2-ton ACST lineup. You get the larger L-size cabinet and higher airflow of the 2-ton model, while the light 5 kW heater keeps the electrical circuit at a 30-amp maximum breaker. It suits two-bedroom condos, apartments, and modest homes in warm climates, and heat pump systems where electric heat mostly serves as backup.
Is a 2 Ton Air Handler with 5 kW Heat the Right Size?
Going from 1.5 to 2 tons raises the ACST's maximum airflow to about 934 CFM and moves up to the wider L cabinet, which is roughly 54" across. This model fits when a space's cooling load calls for 2 tons but the heating load is light, a common situation in Southern and coastal homes.
Cooling load drives the choice of tonnage, and heating needs and available amperage decide the heat strip. If summer heat is the main concern and winters are short, the 5 kW strip (about 15,600 BTU/h at 230V) keeps wiring simple. Homes with longer heating seasons should look at the 8 kW or 10 kW versions.
Ideal for: Two-bedroom condos and apartments, smaller single-family homes, and heat pump systems in warm climates that need 2 tons of cooling with light electric backup heat.
Need more capacity? Step up to the 2 Ton Goodman ACST24LU1308AA with 8 kW Heat for more heating capacity in the same cabinet.
Recommended applications are general guidelines only. Actual system requirements depend on home size, insulation, climate, ductwork, and the matched outdoor unit. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Air Handler | Goodman ACST24LU1305AA — 2 Ton Ceiling Mount Pancake Air Handler |
|---|---|
| Heat Strip | 5 kW Electric Heat, Factory Installed (approx. 15,600 BTU/h at 230V) |
| Cooling Capacity | 24,000 BTU/h Nominal (2 Ton) |
| Refrigerant | R-32 |
| Metering Device | Factory-Installed, Fully Adjustable TXV |
| Electrical | 208/230V, Single Phase, 60 Hz |
| MCA / Max Breaker | 28.5A / 30A at 230V; 25.1A / 30A at 208V |
| Max Airflow | Approx. 934 CFM (T4/T5, 0.1" ESP) |
| Line Connections | 3/8" Liquid, 3/4" Suction |
| Cabinet Height / Ship Weight | 6½" / 97 lbs |
This 2-ton ACST ships with the 5 kW heater kit, TXV, R-32 leak sensor, pull-type disconnect, and mounting brackets factory installed. Choose a matching ceiling access panel from the options above. Ceiling installs often add a secondary safety pan, like our 30" x 60" galvanized overflow drain pan. Check that it fits your cabinet footprint before ordering.
Air Handler & Heat Strip Features
ACST24LU1305AA Ceiling Mount Air Handler
- 2-ton (24,000 BTU/h nominal) R-32 ceiling air handler
- Wider L cabinet, about 54" across, still only 6½" tall
- Up to about 934 CFM on the highest speed taps
- Factory-installed TXV, fully adjustable
- R-32 refrigerant sensor installed at the factory
- All-aluminum tube and fin coil
- Multi-speed ECM blower motor, direct drive
- Front or bottom return, configured in the field
- Quiet operation with a resilient-mount motor
- Easy service access
Factory-Installed 5 kW Electric Heat Strip
- 5 kW heater kit pre-installed by Goodman
- Approx. 15,600 BTU/h of heat at 230V
- Lowest-amperage heat option among the 2-ton ACST models
- 30A maximum breaker at 208V and 230V
- MCA of 28.5A at 230V; 25.1A at 208V
- Sequence-controlled heating elements
- Rust-resistant nickel chromium elements
- Factory-installed pull-type disconnect
- A good match for heat pump systems in warm climates
- Browse all Goodman ceiling mount pancake air handlers
Specifications & Manuals
These Goodman documents include ACST24LU1305AA electrical ratings, 2-ton blower performance, L-cabinet dimensions, installation steps, and replacement parts.
Frequently Asked Questions
Why choose a 5 kW heat strip on a 2-ton air handler?
A 5 kW strip suits homes that need 2 tons of cooling but little electric heat, such as heat pump systems in warm climates. It also keeps the circuit at a 30A maximum breaker.
What electrical circuit does the ACST24LU1305AA need?
Goodman lists 28.5A MCA at 230V (25.1A at 208V), with a 30A maximum overcurrent protection device at either voltage.
How wide is the ACST24LU1305AA cabinet?
The 2-ton ACST uses Goodman's L cabinet, listed at about 54.2" wide. It's 6½" tall. See the technical specifications for the full dimension drawing.
What metering device does this air handler use?
It has a factory-installed, fully adjustable thermostatic expansion valve (TXV), so no field-installed metering kit is needed.
Does the ACST24LU1305AA include a refrigerant leak sensor?
Yes. Goodman factory installs an R-32 sensor designed to last the life of the coil.
How heavy is the 2-ton ACST for ceiling mounting?
Goodman lists a shipping weight of 97 lbs for the ACST24. Plan hanging hardware and structural support according to the installation instructions.


ACST Technical Specifications