decor decor

Summary

Product #180471: $1,395.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Ceiling Access Panel:
1395
$1,395.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
ACST30LU1310AA, ACST30LU1310 | The Flagship ACST: Full 2.5-Ton Cooling with Maximum 10 kW Heat

2.5 Ton Goodman R32 Ceiling Mount Pancake Air Handler, ACST30LU1310AA

· SKU 180471 · Air Handler
Capacity
30,000 BTU
Refrigerant
R-32
Average Rating:
List price: $1,825.00

Sale price:

$1,395.00
You save $430.00!
  • SKU: 180471
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • Product Type:
    Air Handler
  • Tonnage:
    2.5
  • Refrigerant Type:
    R-32
  • Manufacturer Warranty:
    10 Years
  • Heat Strip:
    10kW
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • Goodman Ceiling Access Panel No Louver for ACST Handlers, CAP-3
  • Goodman Ceiling Access Panel Louvered for ACST Handlers, CAP-3L
Adding to cart… The item has been added

2.5 Ton Goodman R32 Ceiling Mount Pancake Air Handler with 10 kW Heat Strip, ACST30LU1310AA

The Goodman ACST30LU1310AA is the top of the ACST ceiling mount lineup. It offers the series' largest cooling size, 2.5 tons (30,000 BTU/h nominal), with a 10 kW electric heat strip factory installed, about 31,300 BTU/h of heat at 230V. It's the model for larger homes and condos that need full cooling and full heating from a single 6½"-tall air handler above the ceiling. That includes cold-winter regions, high-heat-loss floor plans, and straight-cool systems where electric resistance is the only heat source.

Is a 2.5 Ton Air Handler with 10 kW Heat the Right Size?

On cooling, the ACST30LU1310AA matches the other 2.5-ton models at up to about 934 CFM through the L cabinet. What sets it apart is twice the electric heat of the 5 kW version. That matters when long cold spells, large window walls, or older insulation push the heating load well beyond what a mild-climate home needs.

Plan for the heavier circuit before ordering: 54.6A MCA and a 60A maximum breaker at 230V, or 47.6A and 50A at 208V. A heat-loss calculation is the best way to confirm whether 10 kW is the right choice or whether 8 kW will do.

Ideal for: Larger homes, condos, and townhomes with cold winters or high heat loss, plus straight-cool systems that need 2.5 tons of cooling and maximum electric heat from a ceiling air handler.

Need more capacity? The ACST30LU1310AA is the largest model in Goodman's ACST ceiling mount series. For loads beyond 2.5 tons, explore our full range of air handlers with electric heat strips.

Recommended applications are general guidelines only. Actual system requirements depend on home size, insulation, climate, ductwork, and the matched outdoor unit. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Air Handler Goodman ACST30LU1310AA — 2.5 Ton Ceiling Mount Pancake Air Handler
Heat Strip 10 kW Electric Heat, Factory Installed (approx. 31,300 BTU/h at 230V)
Cooling Capacity 30,000 BTU/h Nominal (2.5 Ton)
Refrigerant R-32
Metering Device Factory-Installed, Fully Adjustable TXV
Electrical 208/230V, Single Phase, 60 Hz (197–253V range)
MCA / Max Breaker 54.6A / 60A at 230V; 47.6A / 50A at 208V
Max Airflow Approx. 934 CFM (T4/T5, 0.1" ESP)
Line Connections 3/8" Liquid, 3/4" Suction
Cabinet Height / Ship Weight 6½" / 97 lbs

The ACST30LU1310AA ships with Goodman's 10 kW heater kit, TXV, R-32 sensor, pull-type disconnect, and mounting brackets all installed, so it's ready to hang, pipe, and wire. A matching ceiling access panel is available in the options above. For the 3/8" and 3/4" refrigerant connections, see our 25' 3/4" x 3/8" copper line set, and confirm sizing against your outdoor unit's requirements.

Air Handler & Heat Strip Features

ACST30LU1310AA Ceiling Mount Air Handler

  • The largest ACST combination: 2.5 tons with 10 kW heat
  • 30,000 BTU/h nominal R-32 cooling
  • 6½"-tall galvanized-steel L cabinet
  • Up to about 934 CFM on the highest speed taps
  • Factory-installed, fully adjustable TXV
  • Factory R-32 sensor designed to last the life of the coil
  • All-aluminum tube and fin evaporator coil
  • Configurable front or bottom return
  • Suitable for free-return installation
  • Designed, engineered, and assembled in the USA

Factory-Installed 10 kW Electric Heat Strip

  • 10 kW heater kit, the largest available for the ACST30
  • Approx. 31,300 BTU/h of electric heat at 230V
  • Double the heat of the 5 kW ACST30 model
  • 60A max breaker at 230V; 50A at 208V
  • 54.6A MCA at 230V; 47.6A at 208V
  • Sequence-controlled nickel chromium elements
  • Rust-resistant element construction
  • Factory-installed pull-type disconnect
  • Built for cold winters and electric-only heat
  • Pair with a compatible model from our thermostat selection

Specifications & Manuals

These documents cover 10 kW heater electrical data, 2.5-ton airflow performance, wiring and installation steps, cabinet dimensions, and service parts for the ACST30LU1310AA.

Frequently Asked Questions

Is the ACST30LU1310AA the most powerful ACST air handler?

Yes. It combines the largest ACST cooling size (2.5 tons) with the largest heat strip offered for that size, a factory-installed 10 kW heater.

How much electric heat does 10 kW deliver in this unit?

Goodman rates it at about 31,300 BTU/h at 230V. Output is somewhat lower on 208V service.

What circuit size does the ACST30LU1310AA need?

Plan for 54.6A MCA with a 60A maximum breaker at 230V, or 47.6A MCA with a 50A maximum at 208V. Wire to local code.

What comes factory installed in the ACST30LU1310AA?

The 10 kW heater kit, TXV, R-32 refrigerant sensor, pull-type disconnect, casing, and mounting brackets are all installed by Goodman.

Is the evaporator coil aluminum or copper?

Goodman uses an all-aluminum tube and aluminum fin coil in the ACST series.

Can I connect the ACST30LU1310AA to an existing R-410A condenser?

This air handler is designed and optimized for R-32 refrigerant and should be paired with a matched R-32 outdoor unit. Have your installer confirm the system match before purchase.