W5A5S24AKAWA, W5AM24M14XA, WFSX040A030B | Narrow-cabinet 2 ton comfort built for mild-winter homes

2 Ton EcoTemp 15.5 SEER2 95% AFUE 40K BTU Single Stage Gas System W5A5S24AKAWA, W5AM24M14XA, WFSX040A030B

· SKU 180483 · AHRI 214913968 · Split System
SEER2
15.5
Capacity
24,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,150.00

Sale price:

$3,950.00
You save $1,200.00!
  • SKU: 180483
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    15.5
  • Product Type:
    Split System
  • Tonnage:
    2
  • Operating Mode:
    Gas
  • Refrigerant Type:
    R-454B
  • AFUE %:
    95
  • Airflow Direction:
    Multi-Position
  • Cabinet Width:
    14"
  • Manufacturer Warranty:
    10 Years
  • BTUs:
    40,000
  • EcoTemp (ICP) Natural Gas to Liquid Propane 90%+ LP Kit, AGAGC9NPS01E
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 2 Ton EcoTemp 14.3 SEER2 R454B  Condenser W5A5S24AKAWA
  • 2 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM24M14XA
  • EcoTemp 95% Single Stage 40K BTU Gas Furnace, WFSX040A030B
Adding to cart… The item has been added

EcoTemp 2 Ton 15.5 SEER2 Air Conditioner & 40K BTU Condensing Furnace – 14" Slim-Line System

This is the full 2 ton cooling version of the EcoTemp narrow-cabinet package. It combines the W5A5S24AKAWA R-454B condenser, the W5AM24M14XA coil, and the WFSX040A030B furnace in a 14-3/16 in. wide indoor footprint. The AHRI-certified match (AHRI 214913968) rates 15.5 SEER2 for cooling. The furnace delivers 39,000 BTU of heat at 95% AFUE downflow and up to 96.0% AFUE upflow or horizontal. It's a good fit for Sun Belt and mild-winter homes, townhomes, and slab ranches where cooling sets the size and heat is a lighter, secondary load.

Is a 2 Ton System with a 40K Furnace the Right Size?

Two tons (24,000 BTU) of cooling is often matched to homes of roughly 900 to 1,300 square feet. Pairing it with the smallest WFSX furnace makes sense where winters are short: Florida, the Gulf Coast, the desert Southwest, and coastal California. Choosing more heat than you need on a single-stage furnace mostly adds cost.

The cooling load depends on sun exposure, attic insulation, window glass, and duct location, which is especially important when ducts run through a hot attic. The heating side depends on your local winter design temperature. If your calculated heat loss is above 39,000 BTU, step up to the 60K pairing. A Manual J load calculation answers both questions at once.

Ideal for: Warm-climate homes and townhomes, slab-on-grade ranches, rental properties, and narrow closet or alcove installations in southern markets.

Need more capacity? Choose the EcoTemp 2 Ton 16 SEER2 60K BTU Gas System for more heat and a higher cooling rating in a 17-1/2 in. cabinet.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, ductwork, climate, elevation, and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condenser W5A5S24AKAWA — 2 Ton Single-Stage R-454B Air Conditioner
Indoor Coil W5AM24M14XA — 2 Ton Multipoise Cased A-Coil, 14-3/16" Wide, Factory TXV
Gas Furnace WFSX040A030B — 40,000 BTU Input / 39,000 BTU Output Condensing Furnace
Furnace Cabinet Width 14-3/16" (35" tall)
Cooling Efficiency 15.5 SEER2 (AHRI 214913968)
Heating Efficiency 96.0% AFUE Upflow & Horizontal / 95% AFUE Downflow
Refrigerant R-454B
Compressor Single-Stage Scroll Compressor
Condenser Electrical 208/230V, Single Phase, 60 Hz — 13.6 MCA, 20A Max Fuse/Breaker
Furnace Electrical 115V, Single Phase, 60 Hz — 9.7 Unit Ampacity
Manufacturer Warranty 10-Year Parts with Timely Registration; 20-Year Furnace Heat Exchanger

The coil and condenser in this system are both rated at 2 tons. The 14-3/16 in. coil sets flush on the 14-3/16 in. WFSX040A030B furnace, and the furnace blower's 1,000 CFM maximum cooling airflow covers a 2 ton system. Outdoors, a condenser pad or tie-down kit gives the W5A5S24AKAWA a level base. More EcoTemp sizes are on the EcoTemp brand page.

Condenser, Coil & Furnace Features

W5A5S24AKAWA Condenser & W5AM24M14XA Coil

  • 2 ton scroll compressor rated 10.3 RLA, with internal overload and pressure relief
  • 3,600 CFM direct-drive condenser fan (1/10 HP) over a 19.8 sq. ft. coil face
  • 4.7 lb factory R-454B charge for a 15 ft line set; 3/4 in. rated vapor and 3/8 in. liquid lines
  • 73 dBA standard sound rating, or 71 dBA with the accessory sound shield
  • Filter drier, dense wire coil guard, and a solid sheet-metal cabinet
  • Compatible with programmable or standard single-stage thermostats
  • W5AM24M14XA multipoise A-coil, 25-13/16 in. tall, about 50 lb
  • Factory TXV built for R-454B, with side-mounted tubing for easy valve access
  • Complete A2L dissipation system included and required for installation
  • Vertical and horizontal FRTP drain pans plus UV-light knockouts

WFSX040A030B 40K BTU Condensing Furnace

  • Slim 14-3/16 in. "A" cabinet for alcoves and tight closets
  • 96.0% AFUE upflow and horizontal, 95.0% downflow
  • 39,000 BTU output with two burners and a 40–70°F temperature rise
  • 1/2 HP constant-torque ECM blower: 705 CFM heating, up to 1,000 CFM cooling
  • Upflow, downflow, horizontal left, or horizontal right installation
  • 1-1/2 in., 2 in., or 2-1/2 in. PVC/ABS direct-vent or single-pipe venting (see the venting tables for lengths)
  • White-Rodgers redundant gas valve with a 1/2 in. NPT gas connection
  • High-temperature limit control and flame roll-out sensors
  • Quarter-turn door knobs and a prepainted, corrosion-resistant steel cabinet
  • Through-the-casing flue option for counterflow or horizontal installs (accessory)

Specifications & Manuals

Documentation includes condenser, coil, and furnace product data, installation instructions, line-set and venting tables, wiring diagrams, and warranty terms for selection, installation, and service.

Frequently Asked Questions

Is a 40,000 BTU furnace enough heat for a 2 ton home?

In mild-winter climates it often is. The furnace delivers 39,000 BTU per hour. If a load calculation shows a higher heat loss, the 60K and 80K versions of this 2 ton system are better choices.

Can the 14-inch WFSX blower move enough air for 2 tons of cooling?

Yes. The WFSX040A030B's cooling airflow range is 155 to 1,000 CFM at rated static pressure, which covers the typical airflow for a 2 ton system.

What electrical circuit does the W5A5S24AKAWA condenser need?

A 208/230V single-phase supply with a 13.6 minimum circuit ampacity and a 20 amp maximum time-delay fuse or circuit breaker. Use copper wire from the disconnect to the unit.

Can the furnace and coil be installed horizontally in an attic?

Yes. The WFSX installs horizontal left or right, and the W5AM coil is multipoise with a dedicated horizontal drain pan. Follow the installation instructions for clearances, drain traps, and secondary drain pans.

What is the dissipation system that ships with the W5AM coil?

Because R-454B is an A2L refrigerant, the coil includes a factory-installed refrigerant sensor and harness, plus a leak dissipation control board and housing in the parts box. If it detects a leak, the system runs the blower to disperse refrigerant. It is required for installation.

How do I get the 10-year parts warranty?

Register the equipment within 90 days of the original installation, except in jurisdictions where warranty benefits can't be conditioned on registration. Without registration the default parts coverage is 5 years. See the ICP warranty certificate for full terms.