decor decor

Summary

Product #180485: $4,055.00
  • Natural or Liquid Propane (LP) Gas:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 42060 / 2 Ton EcoTemp R454B Condenser W5A5S24AKAWA (179436) -- 1
  • 47023 / 2 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM24M17XA (180434) -- 1
  • 47147 / EcoTemp 95% Single Stage 80K BTU Gas Furnace, WFSX080B048B (180478) -- 1
4055
$4,055.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
W5A5S24AKAWA, W5AM24M17XA, WFSX080B048B | 2 ton cooling backed by 78,000 BTU of delivered heat

2 Ton EcoTemp 16 SEER2 95% AFUE 80K BTU Single Stage Gas System W5A5S24AKAWA, W5AM24M17XA, WFSX080B048B

· SKU 180485 · AHRI 214915442 · Split System
SEER2
16
Capacity
24,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,270.00

Sale price:

$4,055.00
You save $1,215.00!
  • SKU: 180485
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    16
  • Product Type:
    Split System
  • Tonnage:
    2
  • Operating Mode:
    Gas
  • Refrigerant Type:
    R-454B
  • AFUE %:
    95
  • Airflow Direction:
    Multi-Position
  • Cabinet Width:
    17.5"
  • Manufacturer Warranty:
    10 Years
  • BTUs:
    80,000
  • EcoTemp (ICP) Natural Gas to Liquid Propane 90%+ LP Kit, AGAGC9NPS01E
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 2 Ton EcoTemp 14.3 SEER2 R454B  Condenser W5A5S24AKAWA
  • 2 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM24M17XA
  • EcoTemp 95% Single Stage 80K BTU Gas Furnace, WFSX080B048B
Adding to cart… The item has been added

EcoTemp 2 Ton 16 SEER2 AC with 80,000 BTU 97% AFUE Gas Furnace – 17-1/2" Cabinet

This package keeps cooling at 2 tons and puts 78,000 BTU of delivered heat behind it. The W5A5S24AKAWA R-454B condenser and W5AM24M17XA coil hold the line's top cooling rating of 16 SEER2 (AHRI 214915442). The WFSX080B048B furnace provides the heat at 97.0% AFUE upflow or horizontal. Even at 80,000 BTU input, the furnace keeps the same 17-1/2 in. cabinet width as the 60K model, so cold-climate homeowners and contractors get more heating capacity without a wider footprint. It fits Midwest, Northeast, and high-plains homes where winter drives sizing and summer cooling stays modest.

Who Needs 80K BTU of Heat with a 2 Ton AC?

Homes that are compact in summer but lose heat quickly in winter often need this combination. Examples include older two-story homes, homes with full basements, drafty farmhouses, and houses at higher elevation. These often have cooling loads near 2 tons (24,000 BTU) while their heat loss at a 0°F or colder design day is well above what a 60K furnace delivers.

Single-stage furnaces run at full fire every cycle. An oversized one will short-cycle in mild weather, so choose 80K only when the numbers support it. Above 2,000 ft, the input derates 4% per 1,000 ft, which can make the larger furnace the correct pick at altitude. A Manual J heat-loss calculation is the right basis for that decision.

Ideal for: Cold-climate homes with small cooling loads, older houses with basements, mountain and high-elevation properties, and replacements of an existing 80K furnace with a higher-efficiency model.

Need more capacity? For more cooling, move up to the EcoTemp 2.5 Ton 60K BTU Gas System (W5A5S30AKAWA).

Recommended applications are general guidelines only. Actual system requirements depend on insulation, ductwork, climate, elevation, and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condenser W5A5S24AKAWA — 2 Ton Single-Stage R-454B Air Conditioner
Indoor Coil W5AM24M17XA — 2 Ton Multipoise Cased A-Coil, 17-1/2" Wide, Factory TXV
Gas Furnace WFSX080B048B — 80,000 BTU Input / 78,000 BTU Output Condensing Furnace
Furnace Cabinet Width 17-1/2" (35" tall)
Cooling Efficiency 16 SEER2 (AHRI 214915442)
Heating Efficiency 97.0% AFUE Upflow & Horizontal / 95% AFUE Downflow
Refrigerant R-454B
Compressor Single-Stage Scroll Compressor
Condenser Electrical 208/230V, Single Phase, 60 Hz — 13.6 MCA, 20A Max Fuse/Breaker
Furnace Electrical 115V, Single Phase, 60 Hz — 13.4 Unit Ampacity, 15A Breaker
Manufacturer Warranty 10-Year Parts with Timely Registration; 20-Year Furnace Heat Exchanger

The WFSX080B048B 80K gas furnace shares its 17-1/2 in. cabinet with the 60K model but adds heating airflow: 1,290 CFM at rated static compared with 1,030 CFM. The W5AM24M17XA coil matches that width, for a combined stack of about 60-13/16 in. before the supply plenum. Propane homes can add the LP gas conversion kit, and installers can find copper line sets sized for the 3/4 in. vapor and 3/8 in. liquid connections.

Condenser, Coil & Furnace Features

W5A5S24AKAWA Condenser & W5AM24M17XA Coil

  • 2 ton single-stage condenser with a durable scroll compressor
  • 16 SEER2 matched rating with this coil and 80K furnace
  • Non-ozone-depleting, low-GWP R-454B refrigerant
  • Low-ambient cooling to 0°F with approved accessory kits
  • Long-line support to 250 ft equivalent, with up to 200 ft of rise when the condenser sits above the coil
  • Rated with 25 ft of line set; factory charged for 15 ft of 3/8 in. liquid line
  • W5AM coil fully insulated with foil-faced R-2.1 insulation
  • Dual FRTP condensate pans engineered with slope for full drainage
  • Factory UV-light knockouts for easy add-on air purification
  • Coil warranty: 5-year parts, or 10-year parts with timely registration

WFSX080B048B 80K BTU Condensing Furnace

  • 80,000 BTU input, 78,000 BTU delivered heat
  • 97.0% AFUE upflow and horizontal, 95.0% downflow
  • ENERGY STAR 5.0 North qualified upflow and horizontal
  • Four burners with direct silicon nitride ignition
  • 3/4 HP ECM blower delivering 1,290 CFM heating and 370–1,625 CFM cooling
  • Same 17-1/2 in. by 35 in. cabinet as the 60K model, about 150 lb
  • Stainless steel secondary heat exchanger with a 20-year limited warranty
  • Meets 40 ng/J NOx requirements for air quality management districts
  • NFC tap-to-configure setup with the service technician app
  • Insulated heat exchanger compartment and a prepainted steel cabinet

Specifications & Manuals

Documentation includes condenser, coil, and furnace product data, installation instructions, line-set and venting tables, wiring diagrams, and warranty terms for selection, installation, and service.

Frequently Asked Questions

Who should choose the 80K furnace over the 60K for a 2 ton system?

Homeowners whose calculated heat loss exceeds the 60K model's 58,000 BTU output, which is common in cold northern climates, older homes, and higher elevations. This furnace delivers 78,000 BTU per hour.

What temperature rise does the WFSX080B048B produce?

The certified temperature rise range is 40–70°F. The installer adjusts blower speed so the measured rise falls within that range for your ductwork.

How many burners does the 80K WFSX furnace use?

Four burners, lit by a silicon nitride direct igniter and controlled through a redundant White-Rodgers gas valve.

Can the 2 ton condenser cool when it's cold outside?

With the manufacturer's approved low-ambient accessory kits, the W5A5S can provide cooling down to 0°F outdoor temperature. Those applications also require a crankcase heater and an evaporator freeze thermostat.

What built-in protection does the outdoor unit have?

The W5A5S includes an internal pressure relief valve, internal thermal overload on the compressor, a factory filter drier, and a dense wire coil guard. A cycle protector and time-delay relay are available as accessories.

How tall is the furnace and coil stacked together?

The 35 in. furnace plus the 25-13/16 in. W5AM24M17XA coil come to about 60-13/16 in. before the supply plenum and any transition. Allow extra height for the plenum and filter rack.

Customer Review