2.5 Ton EcoTemp R-454B Multi-Positional Cased Coil, W5AM30M17XA
The W5AM30M17XA is the volume seller of the EcoTemp R-454B coil line: 2.5 tons of capacity in the industry-standard 17-1/2 in. cabinet, on the short 25-13/16 in. body. That combination covers the single most common residential changeout in the country. A refrigerant-specific TXV, 3/4 in. suction connection, a 750 to 1250 CFM rating, twin sloped FRTP drain pans and the full A2L leak dissipation kit make it a straightforward drop-in on standard-width furnaces and blower cabinets in any of the four mounting orientations.
Is a 2.5 Ton Cased Coil the Right Size?
At 30,000 BTUH nominal and 41.5 MBH gross at 1000 CFM, this coil serves mid-size homes, larger townhomes and well-insulated two-story properties where the outdoor unit is a 2.5 ton condenser or heat pump. The wider 17-1/2 in. face gives it noticeably lower coil static pressure drop than the 14 in. version at the same airflow, which is worth having when the blower is an older PSC motor rather than a modern ECM.
As with every coil in the series, the selection is governed by the AHRI-certified pairing rather than by rules of thumb. Verify the certified match for your outdoor unit, then confirm the blower can carry design airflow through the coil plus filter and duct losses. In humid regions, running toward the lower end of the airflow range improves latent removal; in dry regions, higher airflow raises sensible capacity. Both approaches assume the coil is the certified one for that condenser.
Ideal for: Standard 17-1/2 in. furnace and air handler cabinets, 2.5 ton residential changeouts, 1,200 to 1,700 sq. ft. homes, and new construction where a conventional-width coil transition is planned.
Need more capacity? Step up to the 3 Ton EcoTemp W5AM36M17XA Cased Coil, which keeps the 17-1/2 in. width and uses a taller cabinet to gain coil face area.
Recommended applications are general guidelines only. Actual coil selection depends on the AHRI-certified system match, blower capability, duct static, and local design conditions. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Model Number | W5AM30M17XA — 2.5 Ton Multi-Poise Cased Evaporator Coil |
|---|---|
| Nominal Capacity | 2.5 Ton / 30,000 BTUH |
| Coil Type | Vertical A-Coil, Cased |
| Airflow Configuration | Multi-Poise — Upflow, Downflow, Horizontal-Left, Horizontal-Right |
| Refrigerant | R-454B Only |
| Cabinet Width | 17-1/2 in. |
| Cabinet Height | 25-13/16 in. |
| Suction Line Connection | 3/4 in. Sweat |
| Liquid Line Connection | 3/8 in. Sweat |
| Metering Device | Factory-Installed R-454B TXV |
| Rated Airflow Range | 750 – 1250 CFM |
| Operating Weight | 61.0 lb |
| Leak Dissipation | Complete A2L Dissipation System Included |
| Warranty | 5-Year Parts Limited; 10-Year with Registration Within 90 Days |
The natural outdoor pairing is the 2.5 ton EcoTemp W5A5S30AKAWA condenser or the W5H5S30AKAAA heat pump. Compare the rest of the size range on the 2.5 to 3 ton cased coil category, and plan for a field-supplied liquid line filter drier on every changeout.
Cabinet & Coil Features
W5AM30M17XA Cabinet & Construction
- 17-1/2 in. standard-width casing on the short 25-13/16 in. body
- 23.4 in. cabinet depth, consistent across the W5AM series
- 24-gauge pre-painted taupe metallic finish
- Fully insulated with foil-faced R-2.1 material for quiet running
- Two corrosion-resistant FRTP drain pans supplied with the coil
- Sloped pan geometry in both vertical and horizontal orientations
- Primary and secondary 3/4 in. FPT condensate connections
- Factory UV knockouts for quick UV lamp installation
- 61.0 lb operating, 66.5 lb shipping weight
- Ships 23.6 in. high by 18.1 in. wide by 23.4 in. deep
W5AM30M17XA Coil, Metering & Installation
- Larger coil face than the 14 in. 2.5 ton for reduced static pressure drop
- Factory-set R-454B thermostatic expansion valve on every unit
- 3/4 in. suction, 3/8 in. liquid sweat connections
- Straight tube stub-outs sized for braze-less compression fittings
- Side tubing layout keeps both slabs accessible for cleaning
- Refrigerant sensor and harness factory installed for A2L compliance
- Dissipation control board, housing and power harness in the parts box
- Minimum 2100 psi burst pressure rating
- Split delta plate and tool-free front coil removal
- AHRI certified performance data, UL and c-UL listed
Specifications & Manuals
Reference the size 3017 rows in the dimensional and capacity tables, the coil static pressure drop chart for blower sizing, and the horizontal-left and horizontal-right installation figures if the coil is going into an attic run. Registration terms for extended warranty coverage are in the certificate.
Frequently Asked Questions
What is the difference between W5AM30M17XA and W5AM30M14XA?
Capacity, airflow rating and line sizes are identical. The 17-1/2 in. version has a wider coil face, which lowers air-side pressure drop, and it weighs about 6.5 lb more. Pick the 14 in. model only when the opening will not accept 17-1/2 in.
Can the W5AM30M17XA be installed horizontally?
Yes, horizontal-left or horizontal-right. The horizontal drain pan is included, and the installation instructions cover both configurations along with the condensate pan extension and corner screws that get fitted for horizontal work.
What are the shipping dimensions and weight of the 3017 coil?
23.6 in. high, 18.1 in. wide, 23.4 in. deep, at 66.5 lb shipping weight. Operating weight once installed is 61.0 lb.
Does the cabinet come ready for a UV light?
Yes. UV knockouts are factory installed in the casing so a UV lamp kit can be added without cutting sheet metal on site.
What warranty covers the W5AM30M17XA?
A default 5-year parts limited warranty, extending to 10-year parts limited when the equipment is registered within 90 days of original installation. Registration applies to the original purchaser; see the ICP warranty certificate for restrictions.
What condensate drain connections does it use?
Primary and secondary 3/4 in. FPT connections. PVC fittings are recommended on the plastic pan, finger-tight plus 1-1/2 turns, and both primary and secondary lines should be run and trapped.


W5AM Technical Specifications