Rheem 15 Ton R-454B Commercial Packaged Air Conditioner — RACGYB180ACG000BACA0
The Rheem RACGYB180ACG000BACA0 is a 15-ton Commercial Renaissance Classic Series packaged air conditioner, the entry point of Rheem's large-commercial RACG line. Factory-charged with low-GWP R-454B and wired for 208/230V three-phase power, it delivers 172,000 BTU/h AHRI net cooling at an 11.0 EER and 14.2 IEER. Two scroll compressors on independent refrigerant circuits give two true stages of cooling, while the patented SmartShield interlaced MicroChannel coils, factory refrigerant leak detection, and a standard belt-drive VFD supply fan make this convertible downflow/horizontal rooftop a dependable workhorse for large single-zone commercial buildings on 208/230V service.
Is a 15-Ton Package Unit the Right Size?
This 15-ton unit opens Rheem's large-commercial RACG range and is matched to cooling loads near 172,000 to 180,000 BTU/h, which for many commercial buildings works out to roughly 6,000 to 9,000 sq ft of conditioned space. At this capacity, floor area is only a rough starting point — a full engineered load calculation is what actually sizes a rooftop this large.
Occupant density, outside-air ventilation, roof and wall insulation, glazing, and process or kitchen heat all move the requirement well above or below what the square footage suggests. The two-stage dual-circuit design and standard VFD supply fan let this unit modulate to first-stage cooling for much of the season, but that is not a substitute for a commercial (Manual N-style) load calculation, which confirms the capacity fits the zone and keeps humidity in check.
Ideal for: Large retail and big-box floors, worship and assembly halls, gymnasiums, banquet and event spaces, manufacturing and warehouse offices, and other large single-zone commercial areas served by 208/230V three-phase power.
Need more capacity? Step up to the 20-Ton Rheem R-454B 208/230V 3-Phase Package Unit (RACGYB240ACG000BACA0) for the largest single-zone commercial loads.
Recommended applications are general guidelines only. Actual capacity requirements depend on insulation, ventilation, occupancy, solar gain, ceiling height, and local design temperatures. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Model Number | RACGYB180ACG000BACA0 |
|---|---|
| Product Type | Commercial Renaissance Classic Series Straight-Air (Cooling-Only) Packaged Air Conditioner |
| Nominal Capacity | 15 Tons — 180,000 BTU/h (172,000 BTU/h AHRI net cooling) |
| Rated Efficiency | 11.0 EER / 14.2 IEER |
| Refrigerant | R-454B (A2L, factory charged — approx. 167/170 oz (dual circuit)) |
| Compressors | Two Scroll Compressors, Two Stages, Dual Refrigerant Circuits |
| Nominal Airflow | 6,000 CFM — belt-drive supply fan with standard VFD, convertible downflow or horizontal |
| Electrical | 208/230V, 3-Phase, 60 Hz |
| Minimum Circuit Ampacity | 80 A |
| Max Overcurrent Protection | 110 A |
| Manufacturer Warranty | 5-Year Compressor / 1-Year Parts (Commercial) |
The RACGYB180ACG000BACA0 ships as one factory-assembled, wired, and run-tested cabinet with both refrigerant circuits charged with R-454B, so there is no field line set to braze — set it, connect power and ducting, and commission. For curbed rooftop installs, pair it with the matching 15–25 Ton Rheem 14 in. roof curb (RXKG-CBH14). Browse more Rheem equipment or the full packaged air conditioner lineup for related sizes and voltages.
Unit Features
Cooling, Compressors & Coils
- Two scroll compressors on independent refrigerant circuits providing two true stages of cooling
- Factory-charged with low-GWP R-454B refrigerant and factory-installed refrigerant leak detection with automatic mitigation
- Patented PlusOne SmartShield interlaced dual-circuit MicroChannel evaporator and condenser coils
- TXV refrigerant metering with a solid-core liquid-line filter drier on each circuit
- Rated 11.0 EER / 14.2 IEER at 180,000 BTU/h nominal (172,000 BTU/h AHRI net) cooling
- High- and low-pressure protection with built-in Smart Logic and internal compressor line-break overload
- Cooling operation to 125°F ambient; two-fan propeller condenser section
- Heavy galvanized cabinet with forkable base rails and a flexible footprint (unit net weight approx. 1,951 lb)
Airflow, Controls & Serviceability
- High-performance belt-drive supply fan delivering 6,000 nominal CFM
- Standard Variable Frequency Drive (VFD) supply-fan control — runs at half speed on first-stage/constant-fan for lower energy use, quieter operation, and up to 126% more moisture removal at low load (meets ASHRAE 90.1-2022 and CA Title 24)
- Field-convertible airflow — vertical downflow or horizontal side-flow
- PlusOne ServiceSmart access: Qwik-Slide blower assembly and Qwik-Clean drain pan; slide-out rack holds eight 20 x 24 x 2 in. filters
- PlusOne Diagnostics with dual 7-segment LED display, overflow condensate sensor, and external lockable gauge ports
- Ships wired and run-tested; MERV 8 and MERV 13 filters available as factory or field options
- 208/230V, 3-Phase, 60 Hz power: 80 A minimum circuit ampacity, 110 A maximum overcurrent protection, two compressors at 24.4 A RLA each
- Field- and factory-installed options include economizers, low-ambient control, hot-gas reheat, hinged access, smoke detectors, and two-stage 18–72 kW electric heat kits
Specifications & Manuals
Product documentation includes RACG series technical specifications, installation instructions, and warranty information to assist with equipment selection, installation, and service. This unit carries a Rheem limited warranty; see the warranty document above for full coverage terms and conditions.
Frequently Asked Questions
What size space will the RACGYB180ACG000BACA0 cool?
It is matched to large commercial cooling loads near 180,000 BTU/h (172,000 BTU/h AHRI net), which often lands around roughly 6,000 to 9,000 sq ft of commercial space. Because occupancy, ventilation, glazing, and internal heat gain move the real load, size it with an engineered commercial load calculation rather than floor area alone.
What power does the RACGYB180ACG000BACA0 require?
This unit is wired for 208/230V, 3-Phase, 60 Hz. On the standard VFD-Medium drive it needs a minimum circuit ampacity of 80 A and a maximum overcurrent protection device of 110 A (two compressors at 24.4 A RLA each). If your building distributes power at 460V, order the 460V three-phase 15-ton version (RACGYB180ADG) instead.
Is this a two-stage unit with two compressors?
Yes. Every RACGYB unit uses two scroll compressors on independent refrigerant circuits for two true stages of cooling, and a Variable Frequency Drive (VFD) supply fan is standard. Running at first stage with the VFD at reduced speed improves part-load efficiency (IEER) and moisture removal.
Does the VFD supply fan come standard?
Yes. A VFD on the belt-drive supply fan is standard on every RACGYB model. It ramps the fan up smoothly, runs at roughly half speed during first-stage and constant-fan operation for major energy savings and lower noise, and meets ASHRAE 90.1-2022 and California Title 24 multi-speed fan requirements.
Can this rooftop unit be installed downflow and horizontal?
Yes. Airflow is field-convertible between vertical downflow (for curbed rooftop openings) and horizontal side-flow, and the flexible footprint supports a variety of roof curbs. A matching 14 in. Rheem roof curb (RXKG-CBH14) is available for 15–25 ton RACG units.
Does this unit include heat, and what warranty applies?
This is a cooling-only (straight-air) unit; two-stage 18–72 kW electric heat kits are available as factory or field accessories. Rheem provides a limited warranty on the RACG series — typically a 5-year compressor and 1-year parts limited warranty for commercial applications. See the Rheem Limited Warranty document above for full terms.