RACGYB240ACG000BACA0 | All-In-One | Horizontal or Downflow

20 Ton Rheem R454B 208/230V 3Ph Straight Air Package Unit, RACGYB240ACG000BACA0

· SKU 172906 · AHRI 215832198 · Package AC
Capacity
240,000 BTU
Refrigerant
R-454B
Average Rating:
List price: $29,193.00

Sale price:

$21,625.00
You save $7,568.00!
  • SKU: 172906
  • Availability:
    Usually Ships in 7 to 10 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • Product Type:
    Package AC
  • Tonnage:
    20
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-454B
  • Airflow Direction:
    Downflow/Horizontal
  • Voltage:
    208-230V 3PH
  • 18kW Rheem RACG Commercial 208/230V 3Ph Heat Strip, RXJJ-G18KWC
  • 36kW Rheem RACG Commercial 208/230V 3Ph Heat Strip, RXJJ-G36KWC
  • 54kW Rheem RACG Commercial 208/230V 3Ph Heat Strip, RXJJ-G54KWC
Roof Curb
  • 15 - 25 Ton Rheem 14" Roofcurb, RXRX-DGC14
Curb Adapter
Economizer or Fresh Air Damper
  • 15 - 25 Ton Rheem Manual Fresh Air Damper, RXRF-AGA1
  • 15 - 25 Ton Rheem Motorized Fresh Air Damper, RXRF-AGB1
  • 15 - 25 Ton Rheem Downflow/Vertical Economizer, RXRD-11MGDAM3
  • 15 - 25 Ton Rheem Horizontal Economizer, RXRD-11MGHAM3
  • 15 - 25 Ton Rheem Hail Guard Outdoor Coil Louver Kit, RXRX-LKG01
Adding to cart… The item has been added

Rheem 20 Ton R-454B Commercial Packaged Air Conditioner — RACGYB240ACG000BACA0

The Rheem RACGYB240ACG000BACA0 is a 20-ton Commercial Renaissance Classic Series packaged air conditioner rated at 228,000 BTU/h AHRI net cooling with an 11.0 EER and 14.2 IEER, factory-charged with R-454B and wired for 208/230V three-phase power. Two scroll compressors on separate circuits deliver two stages of cooling across an 8,000 CFM belt-drive VFD supply fan, and the patented SmartShield interlaced MicroChannel coils, factory refrigerant leak detection, and PlusOne diagnostics support big open commercial loads. This convertible downflow/horizontal rooftop suits large retail, assembly, and institutional zones on 208/230V service.

Is a 20-Ton Package Unit the Right Size?

This 20-ton unit is a high-capacity rooftop matched to loads near 228,000 to 240,000 BTU/h, frequently roughly 8,000 to 12,000 sq ft in typical commercial construction. Because it serves very large open zones with substantial internal and ventilation loads, sizing from an engineered load analysis rather than square footage is essential.

Ventilation air, high occupancy, large glazing, and cooking or equipment loads can each swing a 20-ton requirement by tons. A packed assembly space or busy retail floor behaves very differently from a lightly occupied warehouse of the same footprint. A proper commercial load calculation confirms whether one 20-ton unit is right, or whether the space is better served by multiple systems, and keeps the two-stage staging and latent (humidity) performance effective.

Ideal for: Big-box retail, large auditoriums and worship halls, field houses and gyms, event centers, and sizable industrial or institutional zones supplied by 208/230V three-phase service.

Need more capacity? Need more than 20 tons? Browse Rheem's larger 25-ton RACG rooftops and the full packaged air conditioner category for additional capacities and voltages.

Recommended applications are general guidelines only. Actual capacity requirements depend on insulation, ventilation, occupancy, solar gain, ceiling height, and local design temperatures. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Model Number RACGYB240ACG000BACA0
Product Type Commercial Renaissance Classic Series Straight-Air (Cooling-Only) Packaged Air Conditioner
Nominal Capacity 20 Tons — 240,000 BTU/h (228,000 BTU/h AHRI net cooling)
Rated Efficiency 11.0 EER / 14.2 IEER
Refrigerant R-454B (A2L, factory charged — approx. 196/204 oz (dual circuit))
Compressors Two Scroll Compressors, Two Stages, Dual Refrigerant Circuits
Nominal Airflow 8,000 CFM — belt-drive supply fan with standard VFD, convertible downflow or horizontal
Electrical 208/230V, 3-Phase, 60 Hz
Minimum Circuit Ampacity 97 A
Max Overcurrent Protection 110 A
Manufacturer Warranty 5-Year Compressor / 1-Year Parts (Commercial)

The RACGYB240ACG000BACA0 ships as one factory-assembled, wired, and run-tested cabinet with both refrigerant circuits charged with R-454B, so there is no field line set to braze — set it, connect power and ducting, and commission. For curbed rooftop installs, pair it with the matching 15–25 Ton Rheem 14 in. roof curb (RXKG-CBH14). Browse more Rheem equipment or the full packaged air conditioner lineup for related sizes and voltages.

Unit Features

Cooling, Compressors & Coils

  • Two scroll compressors on independent refrigerant circuits providing two true stages of cooling
  • Factory-charged with low-GWP R-454B refrigerant and factory-installed refrigerant leak detection with automatic mitigation
  • Patented PlusOne SmartShield interlaced dual-circuit MicroChannel evaporator and condenser coils
  • TXV refrigerant metering with a solid-core liquid-line filter drier on each circuit
  • Rated 11.0 EER / 14.2 IEER at 240,000 BTU/h nominal (228,000 BTU/h AHRI net) cooling
  • High- and low-pressure protection with built-in Smart Logic and internal compressor line-break overload
  • Cooling operation to 125°F ambient; two-fan propeller condenser section
  • Heavy galvanized cabinet with forkable base rails and a flexible footprint (unit net weight approx. 2,045 lb)

Airflow, Controls & Serviceability

  • High-performance belt-drive supply fan delivering 8,000 nominal CFM
  • Standard Variable Frequency Drive (VFD) supply-fan control — runs at half speed on first-stage/constant-fan for lower energy use, quieter operation, and up to 126% more moisture removal at low load (meets ASHRAE 90.1-2022 and CA Title 24)
  • Field-convertible airflow — vertical downflow or horizontal side-flow
  • PlusOne ServiceSmart access: Qwik-Slide blower assembly and Qwik-Clean drain pan; slide-out rack holds eight 20 x 24 x 2 in. filters
  • PlusOne Diagnostics with dual 7-segment LED display, overflow condensate sensor, and external lockable gauge ports
  • Ships wired and run-tested; MERV 8 and MERV 13 filters available as factory or field options
  • 208/230V, 3-Phase, 60 Hz power: 97 A minimum circuit ampacity, 110 A maximum overcurrent protection, two compressors at 28.5 A RLA each
  • Field- and factory-installed options include economizers, low-ambient control, hot-gas reheat, hinged access, smoke detectors, and two-stage 18–72 kW electric heat kits

Specifications & Manuals

Product documentation includes RACG series technical specifications, installation instructions, and warranty information to assist with equipment selection, installation, and service. This unit carries a Rheem limited warranty; see the warranty document above for full coverage terms and conditions.

Frequently Asked Questions

What size space will the RACGYB240ACG000BACA0 cool?

It is matched to large commercial cooling loads near 240,000 BTU/h (228,000 BTU/h AHRI net), which often lands around roughly 8,000 to 12,000 sq ft of commercial space. Because occupancy, ventilation, glazing, and internal heat gain move the real load, size it with an engineered commercial load calculation rather than floor area alone.

What power does the RACGYB240ACG000BACA0 require?

This unit is wired for 208/230V, 3-Phase, 60 Hz. On the standard VFD-Medium drive it needs a minimum circuit ampacity of 97 A and a maximum overcurrent protection device of 110 A (two compressors at 28.5 A RLA each). If your building distributes power at 460V, order the 460V three-phase 20-ton version (RACGYB240ADG) instead.

Is this a two-stage unit with two compressors?

Yes. Every RACGYB unit uses two scroll compressors on independent refrigerant circuits for two true stages of cooling, and a Variable Frequency Drive (VFD) supply fan is standard. Running at first stage with the VFD at reduced speed improves part-load efficiency (IEER) and moisture removal.

Does the VFD supply fan come standard?

Yes. A VFD on the belt-drive supply fan is standard on every RACGYB model. It ramps the fan up smoothly, runs at roughly half speed during first-stage and constant-fan operation for major energy savings and lower noise, and meets ASHRAE 90.1-2022 and California Title 24 multi-speed fan requirements.

Can this rooftop unit be installed downflow and horizontal?

Yes. Airflow is field-convertible between vertical downflow (for curbed rooftop openings) and horizontal side-flow, and the flexible footprint supports a variety of roof curbs. A matching 14 in. Rheem roof curb (RXKG-CBH14) is available for 15–25 ton RACG units.

How is the 20-ton different from the 15-ton RACG unit?

The 20-ton delivers 228,000 BTU/h AHRI net cooling versus 172,000 for the 15-ton, moves 8,000 CFM versus 6,000, and carries a larger refrigerant charge, while keeping the same 11.0 EER / 14.2 IEER rating and two-compressor, two-stage design. Choose the size from an engineered load calculation for the zone.