NAPCO 24250 Electric Heat Restring Kit 2500W 240V / 1875W 208V, 3/8 in. Coil – Closeout
The NAPCO 24250 is a 2.5 kW replacement coil kit for restringing a burned-out open-coil element in an electric strip heater, electric furnace, duct heater, air handler or wall heater. It's rated 2,500 watts at 240V and about 1,875 watts at 208V. The close-wound nichrome coil has a 3/8 in. outside diameter and comes with 10-32 terminal bolts already attached. NAPCO lists it as fitting ceramic insulators with 3/8 in. inside-diameter openings, and it's interchangeable with the Supco DH503. This lower-wattage kit is a quick, inexpensive fix for smaller elements, with no need to replace a whole heat strip. It's new old stock, and it is our last one, priced to clear.
Is the 24250 the Right Restring Kit for Your Element?
Match three things before you order: wattage and voltage, coil diameter, and stretched length. The 24250 is a 2,500 W at 240V coil, so use it to replace an element of the same rating. A higher-wattage coil would draw more current than the circuit and controls were designed for, and a lower one would leave you short on heat. Its 3/8 in. coil is sized for ceramic insulators with 3/8 in. openings, common in many strip heaters and duct heaters.
Next, compare the stretched length of your original coil between terminals, and confirm your heater uses bolt-type terminal connections. Stretch the new coil evenly so the turns are spaced consistently and don't touch each other or the heater frame. After any element failure, check the high-limit switches, fusible links, sequencers and airflow, so the root cause is fixed along with the coil.
Ideal for: HVAC technicians and maintenance staff repairing a single 2.5 kW, 240V open-coil element in strip heaters, electric furnaces, duct heaters, air handlers and wall heaters that use 3/8 in. insulators.
Need a higher-wattage coil? Our NAPCO 24500 5 kW electric heat restring kit is also a closeout. If the whole heater is damaged, see our 8 kW Nordyne electric heat strip.
Product photo is a stock image for reference only. The actual kit, label and packaging may look different. Fitment information is a general guide only. Always match wattage, voltage, coil diameter and length to your existing element before ordering. This is a single new old stock kit sold as a closeout. Request part-matching help, contact Budget Heating, or call 813-885-7999.
What's Included
| Part Number | 24250 (KIT-24250) — NAPCO Electric Heat Restring Kit |
|---|---|
| Equivalent | Supco DH503 |
| Rated Output | 2,500 W at 240V |
| Output at 208V | Approximately 1,875 W |
| Coil Outside Diameter | 3/8 in. |
| Insulator Fit | Ceramic Insulators with 3/8 in. ID Openings |
| Terminals | 10-32 Male Bolts, Attached |
| Element Material | Close-Wound Nichrome Coil |
| Condition | New Old Stock, Closeout, Last Kit |
NAPCO's restring kits include one close-wound coil with terminal bolts attached, two sets of ceramic terminal bushings, four hex nuts, two lock washers and two flat washers. That's everything needed to mount the new coil's terminals. Check the package contents before starting, and replace any cracked ceramic insulators in the heater so the new coil is fully supported.
Kit Features & Service Notes
NAPCO 24250 Restring Kit
- Replacement coil for 2.5 kW open-coil heating elements
- Rated 2,500 W at 240V, about 1,875 W at 208V
- 3/8 in. outside-diameter close-wound nichrome coil
- Fits ceramic insulators with 3/8 in. openings
- 10-32 terminal bolts attached to the coil
- Includes ceramic terminal bushings, nuts and washers
- Interchangeable with Supco DH503
- For strip heaters, electric furnaces and duct heaters
- Also used in air handlers and wall heaters
- Low-cost alternative to replacing a complete heat strip
Closeout Buying & Installation Notes
- New old stock, kept on our shelf
- Last kit available at closeout pricing
- Use only where the original element was 2.5 kW at 240V
- Confirm your insulators have 3/8 in. openings
- Stretch the coil evenly to the original element length
- Keep coil turns from touching each other or the frame
- Replace cracked or chipped ceramic insulators
- Check limits, fusible links and sequencers after a failure
- Installation by a qualified technician is recommended
- Disconnect power and lock out the circuit before service
Specifications & Manuals
Manufacturer documentation for this closeout restring kit is not posted. For help matching a replacement coil to your heater, contact Budget Heating at 813-885-7999 before ordering.
Frequently Asked Questions
Is the NAPCO 24250 the same as the Supco DH503?
Yes. The Supco/NAPCO restring kit catalog lists NAPCO KIT-24250 and Supco DH503 as the same 2,500 W at 240V coil, and either part number can be used to order it.
What size insulators does this coil fit?
The 24250 is a 3/8 in. outside-diameter coil designed for ceramic insulators with 3/8 in. inside-diameter openings, common in many strip heaters and duct heaters.
What hardware comes with the kit?
NAPCO restring kits include the coil with terminal bolts attached, two sets of ceramic terminal bushings, four hex nuts, two lock washers and two flat washers.
Can I use a 2.5 kW coil to replace a 5 kW element?
No. Always match the original element's wattage and voltage. A lower-wattage coil reduces heat output, and mismatched elements can unbalance the heater. For 5 kW elements, use a 5 kW kit such as the NAPCO 24500.
How do I stretch a new restring coil correctly?
Stretch the coil gradually and evenly to roughly the length of the original element, keeping the turns uniformly spaced. Avoid overstretching or kinking the wire, and make sure no turns touch each other or the frame.
Will the kit match the product photo?
The photo is a stock image. This new old stock NAPCO kit may come in packaging that looks different from the picture.