NAPCO 24500 Electric Heat Restring Kit 5000W 240V / 3750W 208V – Closeout
The NAPCO 24500 is a 5 kW replacement heating coil kit for restringing burned-out open-coil elements in electric furnaces, strip heaters, duct heaters, air handlers and air curtains. It's rated 5,000 watts at 240V, which works out to about 3,750 watts at 208V. The heavy-gauge nichrome coil has welded terminal bolts for a low-resistance, long-lasting connection. Restringing a single failed coil is a fast, inexpensive repair compared with replacing a complete heat strip or heater assembly. This kit is new old stock, and it is our last one. It has been on our shelf since it came in and is priced to clear.
Is the 24500 the Right Restring Kit for Your Heater?
A restring kit has to match the coil it replaces in three ways: wattage and voltage, coil outside diameter, and stretched length. This kit is rated 5,000 W at 240V. Use it where the original coil was also a 5 kW, 240V element. A coil with a different rating changes the heater's output and current draw, and can overload the circuit or leave the system short on heat.
Before you buy, measure the outside diameter of your old coil and check that it will seat properly in your heater's ceramic insulators. Compare the stretched length between terminals, and confirm the terminal connection type. NAPCO also offers 24500-series kits in specific diameters, such as 7/16 in., 1/2 in., 5/8 in. and 3/4 in., so matching the OD is the key to a proper fit. If any heater element has failed, also check the limit switches, fusible links and sequencers before returning the system to service.
Ideal for: HVAC technicians and maintenance teams repairing a single burned-out 5 kW, 240V open-coil element in an electric furnace, strip heater, duct heater, air handler or air curtain.
Need a complete heat strip instead? If the heater assembly itself is damaged, see our 15 kW Nordyne electric heat strip or 15 kW Amana electric heat strip.
Product photo is a stock image for reference only. The actual kit, label and packaging may look different. Fitment information is a general guide only. Always match wattage, voltage, coil diameter and length to your existing element before ordering. This is a single new old stock kit sold as a closeout. Request part-matching help, contact Budget Heating, or call 813-885-7999.
What's Included
| Part Number | 24500 — NAPCO Electric Heat Restring Kit |
|---|---|
| Application | Electric Furnaces, Strip Heaters, Duct Heaters, Air Handlers, Air Curtains |
| Rated Output | 5,000 W at 240V |
| Output at 208V | Approximately 3,750 W |
| Element Material | Heavy-Gauge Nichrome Coil |
| Terminals | Welded Terminal Bolts |
| Condition | New Old Stock, Closeout, Last Kit |
You receive one NAPCO 24500 restring kit. Check the package contents against your repair before starting. Reuse your heater's existing ceramic insulators if they are clean and uncracked, and replace any damaged insulators so the new coil is fully supported. Stretch the coil evenly to the length of the original element, so its turns don't touch each other or the heater frame.
Kit Features & Service Notes
NAPCO 24500 Restring Kit
- Replacement coil for open-coil electric heating elements
- Rated 5,000 W at 240V
- Produces about 3,750 W at 208V
- Heavy-gauge nichrome construction
- Welded terminal bolts for low resistance and longer life
- Fits a wide range of electric furnaces and strip heaters
- Also used in duct heaters, air handlers and air curtains
- Restores one failed element without replacing the whole heater
- Economical repair compared with a new heat strip
- From NAPCO, a long-standing HVAC repair-parts brand
Closeout Buying & Installation Notes
- New old stock, kept on our shelf
- Last kit available at closeout pricing
- Use only where the original element was 5 kW at 240V
- Measure the old coil's OD to confirm it fits your insulators
- Stretch the coil evenly to the original element length
- Keep the coil turns from touching each other or the frame
- Replace any cracked or damaged ceramic insulators
- Check limits, fusible links and sequencers after an element failure
- Installation by a qualified technician is recommended
- Disconnect all power and lock out the circuit before service
Specifications & Manuals
Manufacturer documentation for this closeout restring kit is not posted. For help matching a replacement coil to your heater, contact Budget Heating at 813-885-7999 before ordering.
Frequently Asked Questions
Why is this kit 5,000 W at 240V but only about 3,750 W at 208V?
A heating coil has a fixed resistance, so its output depends on the supply voltage. At 208V the same coil produces roughly three-quarters of its 240V rating, or about 3,750 watts.
How do I know the coil will fit my heater?
Compare the outside diameter of your old coil with the new one, and make sure it seats in your heater's ceramic insulators. Then confirm the stretched length between terminals and the terminal style. Wattage and voltage should match the original element as well.
Can I restring an element instead of replacing the heat strip?
Often, yes. If only the coil has burned through and the frame, insulators and controls are in good shape, restringing is a quick, low-cost repair. Replace the full assembly if the frame or insulators are damaged.
Why did my heating element burn out?
Common causes include low airflow from a dirty filter or a failing blower, a stuck sequencer or relay, and coil sag that lets the turns touch. Find and correct the cause so the new coil doesn't fail the same way.
Do I need to replace the ceramic insulators?
Only if they're cracked, chipped or heavily discolored. Good insulators can be reused, but damaged ones can let the coil shift or short to the frame.
Does the kit look like the product photo?
The photo is a stock image. This new old stock NAPCO kit may come in packaging that looks different from the picture.