Mini Split 9,000 BTU Gree Vireo 26 SEER2 Heat Pump System VIR09HP230V1R32AO, VIR09HP230V1R32AH
The VIR09HP230V1R32AO condenser and VIR09HP230V1R32AH air handler pair 26.0 SEER2 with a 15.0 EER2 and a class-leading 10.4 HSPF2, making this the small-capacity Vireo to specify when winter operating cost is the deciding factor. It is rated 9,100 BTU/h cooling at 95°F and a generous 10,500 BTU/h heating at 47°F — heating output that exceeds its cooling rating — with a 3.9 COP at 47°F and rated operation from -22°F to 86°F in heating. Current draw is remarkably low at 4.73 A in cooling on a 10-amp circuit. Wireless LCD remote and factory Wi-Fi included, with a 5-year parts and 7-year compressor warranty.
Small Capacity, Serious Heating Numbers
Most 9,000 BTU systems are chosen on cooling and treated as a bonus in winter. This one inverts that: 10,500 BTU/h at 47°F against a 9,100 BTU/h cooling rating, a 3.9 coefficient of performance, and a 10.4 HSPF2 mean it delivers roughly four units of heat per unit of electricity in mild conditions. For a room addition, an ADU, or a bedroom in a heating-dominant climate, that changes the annual cost picture substantially.
Sizing still comes down to load. Wall and ceiling insulation, glazing area and orientation, air leakage, ceiling height, and internal gains from people and equipment all determine whether 9,100 BTU/h is comfortable or marginal on a design day. Because the system draws so little current — 4.73 A cooling, 6 A heating, a 10 A minimum circuit ampacity and a 10-amp two-pole breaker — adding it to an existing panel is usually straightforward even when several zones are planned.
Ideal for: Room additions and ADUs, guest suites, heating-dominant climates, bedrooms and offices in new construction, whole-home projects built from multiple single-zone systems, and any small zone where operating cost over a long winter is the priority.
Need more capacity? Step up to the 12,000 BTU Gree Vireo 24.5 SEER2 Heat Pump System for larger single rooms.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, glazing, ceiling height, ambient conditions, occupancy, and internal heat gain. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condenser | VIR09HP230V1R32AO — 9,000 BTU Inverter Heat Pump Condenser |
|---|---|
| Indoor Air Handler | VIR09HP230V1R32AH Wall-Mount Ductless Air Handler |
| Application | Single-Zone Ductless Mini Split Heat Pump System |
| Refrigerant | R-32, 30 oz Factory Charge |
| Compressor | High-Efficiency DC Inverter, 2,730–12,966 BTU/h Cooling Range |
| Rated Capacity | 9,100 BTU/h Cooling @ 95°F / 10,500 BTU/h Heating @ 47°F |
| Efficiency | 26.0 SEER2 / 15.0 EER2 / 10.4 HSPF2 / 3.9 COP @ 47°F |
| Operating Range | Cooling -20°F to 122°F / Heating -22°F to 86°F |
| Electrical | 208-230V, Single Phase, 60 Hz — 10 A MCA, 10 A Suggested Breaker |
| Included Control | Wireless Remote with LCD Display; Factory-Installed Wi-Fi |
| Warranty | 5 Years Parts / 7 Years Compressor |
AHRI certification 214779340 applies to this matched pair. The 70.6 lb condenser carries a 30 oz R-32 charge covering 25 feet of line set, adding 0.2 oz per foot beyond, with flare connections at 1/4 inch liquid and 3/8 inch gas, pipe length from 10 to 66 feet, and 40 feet of allowable elevation difference. Supply voltage range is 187–253 VAC. The indoor head measures 32-1/2 x 11-9/16 x 7-3/4 in. at 20.9 lb, runs 25 to 40 dB(A), and removes 1.69 pt/hr of moisture. Wired controller options are available.
Condenser & Air Handler Features
VIR09HP230V1R32AO Outdoor Condenser
- 10.4 HSPF2 with a 3.9 COP at 47°F for low winter operating cost
- Heating capacity of 10,500 BTU/h exceeds the 9,100 BTU/h cooling rating
- 26.0 SEER2 seasonal cooling with a strong 15.0 EER2 at full load
- Draws only 4.73 A in cooling and 6 A in heating on 208-230V power
- 10 A minimum circuit ampacity with a 10 A suggested breaker size
- Rated heating operation to -22°F and cooling to 122°F
- 30 oz R-32 charge pre-set for 25 feet of line set
- Intelligent defrosting and intelligent preheating
- Blue-colored fin coil coating tested to 500 hours of salt spray
- Easy service access on a 31-37/64 in. wide cabinet, 70.6 lb net
VIR09HP230V1R32AH Wall-Mount Air Handler
- Low 25 dB(A) minimum sound pressure with a 40 dB(A) maximum
- Wireless remote with LCD display included, plus factory-installed Wi-Fi
- Seven fan speeds spanning 159 to 353 CFM of airflow
- 1.69 pt/hr dehumidification with dedicated dry mode
- I-Feel function senses temperature at the remote, not the ceiling
- Auto, Quiet, Sleep, Turbo, and Energy Saving operating modes
- Auto-Clean function on the indoor unit
- Dry anti-mildew X-Fan mode clears the coil after each cycle
- Composite drain pan for corrosion resistance
- Slim 32-1/2 x 11-9/16 x 7-3/4 in. cabinet at 20.9 lb net
Specifications & Manuals
Use the submittal for clearances and electrical rough-in and the installation instructions for evacuation and charging procedure. This capacity takes a 1/4" and 3/8" insulated copper line set; compare configurations across the range on our single-zone heat pump mini split selector.
Frequently Asked Questions
What does a 3.9 COP at 47°F mean for my heating bill?
Coefficient of performance is heat delivered divided by electricity consumed. At 3.9, the system moves roughly 3.9 units of heat for every unit of electricity it draws at that condition — versus 1.0 for electric resistance heat. Combined with the 10.4 HSPF2 seasonal rating, that is the strongest heating economy in the small-capacity Vireo range.
Why does the 230V version have a lower SEER2 than the 115V 9,000 BTU model?
The 115V model is rated 27.0 SEER2 against 26.0 here, but this one posts a higher heating figure — 10,500 BTU/h at 47°F versus 10,000, with a 10.4 HSPF2. They are tuned differently. Choose the 115V version to avoid new electrical work, and this one when a 230V circuit is available and heating performance matters.
Can I install several of these on one electrical panel?
The low current draw makes it practical — a 10 A minimum circuit ampacity per system means a modest panel can often support three or four zones. Total connected load, panel bus rating, and available breaker spaces still need checking by an electrician, and each system requires its own dedicated two-pole circuit.
What is the difference between dry mode and dehumidification capacity?
The 1.69 pt/hr figure is how much moisture the system removes while cooling normally. Dry mode is a separate operating mode that prioritizes moisture removal over temperature, running the compressor and blower at conditions that maximize condensation — useful on cool, damp days when the room does not need cooling but does need drying.
Does the outdoor unit need clearance on all sides?
Yes. The coil draws air through the back and sides and discharges through the front, so restricting any of those surfaces recirculates hot air and cuts capacity. The submittal specifies minimum clearances; in practice, keep the discharge face clear, avoid tight alcoves, and allow service room at the valve end.
Is registration required to keep the warranty valid?
The system carries 5 years parts and 7 years compressor coverage. Manufacturer terms commonly require registration within a set window after installation and proof of installation by a qualified technician for full coverage — check the current terms in the owner's manual and register promptly rather than assuming.
Gree Vireo 9K Submittal Sheet
Gree Vireo Installation Instructions
Gree Vireo Owners Manual
Gree Vireo Parts List