Mini Split 12,000 BTU Gree Vireo 24.5 SEER2 Heat Pump System VIR12HP230V1R32AO, VIR12HP230V1R32AH
One ton of premium ductless capacity on a 10-amp circuit. The VIR12HP230V1R32AO condenser and VIR12HP230V1R32AH air handler deliver 12,000 BTU/h of cooling at 95°F and 12,000 BTU/h of heating at 47°F at 24.5 SEER2, 13.0 EER2, and 9.5 HSPF2, while drawing just 6.64 A in cooling and 6.41 A in heating — less than half the current of the 115V version of the same capacity. Rated operation spans -20°F to 122°F in cooling and down to -22°F in heating, and the inverter sweeps from 2,730 up to 15,695 BTU/h. Wireless LCD remote and factory Wi-Fi included, with a 5-year parts and 7-year compressor warranty.
Matching One Ton to a Real Room
Twelve thousand BTU is the size most often specified for a primary bedroom, a home office, or a single open living space, and this is the version to choose when a 240V feed is available. The efficiency advantage over the value tier shows up in the electrical numbers as much as the SEER2 rating — 6.64 A in cooling on a 10 A minimum circuit ampacity is exceptionally light for a full ton, which matters when several zones share one panel.
Because a ductless head conditions the air in the room it occupies, layout constrains performance as much as capacity does. Doorways, partial walls, and hallways all interrupt distribution regardless of nameplate size. Beyond layout, the load drivers are insulation and air sealing, glazing area and shading, ceiling height, roof or attic exposure, and heat from occupants and electronics. This model also uses a 1/2 inch gas line rather than the 3/8 inch used by comparable value-tier systems — confirm before reusing existing copper.
Ideal for: Primary bedrooms, home offices and studios, living rooms in compact homes, finished basements, in-law suites, small professional offices, and multi-zone projects assembled from individual single-zone systems.
Need more capacity? Step up to the 18,000 BTU Gree Vireo 24.5 SEER2 Heat Pump System for open-plan living areas and combined spaces.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, room layout, glazing, ceiling height, ambient conditions, occupancy, and internal heat gain. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condenser | VIR12HP230V1R32AO — 12,000 BTU Inverter Heat Pump Condenser |
|---|---|
| Indoor Air Handler | VIR12HP230V1R32AH Wall-Mount Ductless Air Handler |
| Application | Single-Zone Ductless Mini Split Heat Pump System |
| Refrigerant | R-32, 28.2 oz Factory Charge |
| Compressor | High-Efficiency DC Inverter, 2,730–15,013 BTU/h Cooling Range |
| Rated Capacity | 12,000 BTU/h Cooling @ 95°F / 12,000 BTU/h Heating @ 47°F |
| Efficiency | 24.5 SEER2 / 13.0 EER2 / 9.5 HSPF2 / 3.8 COP @ 47°F |
| Operating Range | Cooling -20°F to 122°F / Heating -22°F to 86°F |
| Line Set | 1/4 in. Liquid x 1/2 in. Gas, Flared Connections |
| Electrical | 208-230V, Single Phase, 60 Hz — 10 A MCA, 10 A Suggested Breaker |
| Included Control | Wireless Remote with LCD Display; Factory-Installed Wi-Fi |
| Warranty | 5 Years Parts / 7 Years Compressor |
This pairing is AHRI certified under 214813257. The 67.3 lb condenser — the lightest in the Vireo R32 range — carries a 28.2 oz R-32 charge good for 25 feet of line set, with 0.2 oz added per foot beyond, pipe length from 10 to 66 feet, and 40 feet of allowable elevation difference. Supply voltage range is 187–253 VAC with 15 A maximum overcurrent protection. The indoor head measures 32-31/64 x 11-17/32 x 7-23/32 in. at 20.9 lb, moves 230 to 400 CFM across seven fan speeds, and runs from 20 dB(A).
Condenser & Air Handler Features
VIR12HP230V1R32AO Outdoor Condenser
- Only 6.64 A rated cooling current — under half the 115V version's draw
- 10 A minimum circuit ampacity with a 10 A suggested breaker size
- 24.5 SEER2 with 13.0 EER2 and a 3.8 COP at 47°F
- Inverter heating range of 3,070 to 15,695 BTU/h
- Rated heating operation to -22°F and cooling to 122°F
- 28.2 oz R-32 charge pre-set for 25 feet of line set
- 1/4 in. liquid by 1/2 in. gas flared connections
- Intelligent defrosting and intelligent preheating
- Blue-colored fin coating tested to 500 hours salt spray
- Lightest condenser in the Vireo R32 series at 67.3 lb net
VIR12HP230V1R32AH Wall-Mount Air Handler
- Seven fan speeds delivering 230 to 400 CFM of airflow
- Included wireless LCD remote plus factory-installed Wi-Fi
- Quiet operation from 20 dB(A) to 43 dB(A)
- 2.96 pt/hr dehumidification capacity
- I-Feel function reads temperature at the remote for true comfort control
- Auto-Clean function on the indoor unit
- Turbo mode for fast recovery after setback
- Dry anti-mildew X-Fan mode dries the coil at shutdown
- Composite drain pan resists corrosion and staining
- Low-profile 32-31/64 in. cabinet at 20.9 lb net weight
Specifications & Manuals
This model requires a 1/4" and 1/2" insulated copper line set — do not reuse a 3/8 inch gas line from an older 12,000 BTU system. Mounting hardware and anti-vibration pads are available under mini split copper and accessories.
Frequently Asked Questions
How can a full ton run on a 10-amp breaker?
Inverter efficiency. At 24.5 SEER2 and 13.0 EER2 the system produces 12,000 BTU/h while drawing 6.64 A at 208-230V, which yields a 10 A minimum circuit ampacity and a 10 A suggested breaker. Maximum overcurrent protection is 15 A. Always size the actual conductors for the run length and per local code.
Can I reuse the line set from an old 12,000 BTU mini split?
Usually not. This model needs a 1/2 inch gas line, while many older and value-tier 12,000 BTU systems use 3/8 inch. Even when the diameter matches, reused copper should be pressure tested, and residual mineral oil from an R-22 system is incompatible with the POE oil used in R-32 equipment.
Which is the better buy at 12,000 BTU — the Vireo or the Livo?
The Vireo is the efficiency and features play: 24.5 SEER2 and 9.5 HSPF2 with seven fan speeds, factory Wi-Fi, and heating rated to -22°F. The 12,000 BTU Livo is 19 SEER2 with heating to -13°F at a lower price. Heavy-use spaces and cold climates favor the Vireo; light-duty or budget-driven projects favor the Livo.
Does the composite drain pan need a condensate pump?
Only if gravity drainage is not available. The indoor unit drains by gravity through the wall penetration, which works when the head is above the discharge point with continuous fall. Below-grade installations and interior walls without a downhill path need a condensate pump — verify the drain route before setting the mounting plate.
What happens if the power goes out while the system is running?
Memory and power-failure recovery restore the previous mode and setpoint automatically when power returns, so the system resumes without anyone pressing a button. That matters most in spaces that are not occupied daily, such as a rental unit between guests or an office over a long weekend.
Is the indoor unit the same size as the 9,000 BTU Vireo head?
Very close but not identical. This head measures 32-31/64 x 11-17/32 x 7-23/32 in. at 20.9 lb, while the 230V 9,000 BTU head is 32-1/2 x 11-9/16 x 7-3/4 in. at the same weight. Both need continuous wall width and framing to anchor the mounting plate — check the submittal for clearances above and to each side.
Gree Vireo 12K Submittal Sheet
Gree Vireo Installation Instructions
Gree Vireo Owners Manual
Gree Vireo Parts List