Liquid Line Filter Drier Sporlan 1/4 inch 3cu sweat solder connection C-032-S
***NOT FOR HEAT PUMPS. SINGLE REFRIGERANT FLOW DIRECTION***

The Sporlan C-032-S Catch-All Liquid Line Filter Drier provides reliable contamination control for air-conditioning and refrigeration systems. It captures moisture, acids, dirt, scale, solder particles, and other harmful debris circulating through the refrigerant circuit, helping protect expansion devices, compressors, and other sensitive components.

The C-032-S uses a molded porous desiccant core that directs refrigerant through the filtering material for effective contaminant removal. Its compact sealed-steel body is equipped with 1/4-inch ODF copper solder connections for installation in smaller liquid-line applications.

This model has a 3-cubic-inch desiccant volume and a maximum working pressure of 650 PSIG. It is commonly listed for smaller refrigeration and air-conditioning systems up to approximately 1/2 ton, but final sizing should be based on the refrigerant, operating conditions, and Sporlan application data.

Key Features

  • Genuine Sporlan Catch-All filter drier
  • 1/4" ODF solder inlet and outlet
  • 3 cu. in. desiccant volume
  • Removes moisture, acids, and solid debris
  • Molded porous core helps prevent refrigerant bypass
  • Helps protect capillary tubes and expansion devices
  • Compact sealed-steel construction
  • 650 PSIG maximum working pressure
  • UL listed
  • Suitable for CFC, HCFC, and HFC refrigerant systems.

Installation Note

Install the filter drier in the refrigerant-flow direction shown by the arrows on the shell. Proper selection, brazing, and installation should be completed by a qualified HVAC or refrigeration technician.


The Sporlan C-083-S Catch-All Liquid Line Filter Drier provides dependable contaminant protection for air-conditioning and refrigeration systems. It is designed to remove moisture, acids, dirt, scale, solder particles, sludge, carbon, and other foreign material from the refrigerant circuit.

The molded porous core uses a specially formulated blend of desiccants to provide effective moisture and acid removal while maintaining low refrigerant pressure drop. Refrigerant is directed through the core for maximum contact, and an outlet safety filter provides additional protection against loose particles reaching the expansion valve, solenoid valve, capillary tube, or compressor.

The C-083-S features 3/8-inch ODF copper solder connections and a durable sealed steel shell. Its compact design makes it suitable for new HVAC and refrigeration installations, equipment repairs, and replacement applications.

Key Features

  • Sealed Catch-All liquid line filter drier
  • 3/8" ODF solder inlet and outlet connections
  • Removes moisture, acids, dirt, scale, carbon, sludge, and solder particles
  • Molded porous desiccant core prevents refrigerant bypass
  • Helps protect expansion valves and other system components
  • Outlet safety filter provides additional contaminant protection
  • Solid copper sweat connections
  • Durable leak-resistant steel shell
  • Maximum working pressure of 650 PSIG
  • UL listed

Product Specifications

  • Brand: Sporlan
  • Manufacturer: Parker Hannifin
  • Series: Catch-All
  • Model: C-083-S
  • Manufacturer Part Number: 400503
  • UPC: 687472163121
  • Product Type: Liquid Line Filter Drier
  • Body Style: Sealed
  • Application: Air Conditioning and Refrigeration
  • Connection Size: 3/8" x 3/8"
  • Connection Type: ODF Solder
  • Nominal Core Size: 8 cu. in.
  • Approximate Desiccant Volume: 9 cu. in.
  • Filter Area: 21 sq. in.
  • Nominal Application Range: 3/4 to 2-1/2 Tons
  • Maximum Working Pressure: 650 PSIG
  • Overall Length: Approximately 5.25"
  • Body Diameter: Approximately 2.62"
  • Flow Direction: One-Way
  • Refrigerants: R-22, R-134a, R-404A, R-407A, R-407C, R-410A, and R-507

Installation Note

Install the filter drier in the direction indicated by the flow arrows. The C-083-S is designed for one-way refrigerant flow and should not be subjected to reverse flow. Product sizing and installation should be completed by a qualified HVAC or refrigeration professional.


The universal acceptance of the Catch-All? Filter-Drier is due to its unique molded porous core, consisting of a blend of highly effective desiccants. The quality features built into it assure years of service on any refrigeration system.

  • MOISTURE - The Catch-All Filter-Drier removes moisture from the refrigerant by adsorbing and retaining it deep within the desiccant granules. The blend of desiccants used in the Catch-All Filter-Drier are specially formulated for exceptional water removal.
  • FOREIGN MATTER - The Catch-All Filter-Drier will filter out scale, solder particles, carbon, sludge, dirt or any other foreign matter with negligible pressure drop. Fine particles that would go through an ordinary strainer are removed down to a minimum size in one pass filtration. The large filtering area of the Catch-All Filter-Drier core permits it to collect a large amount of dirt without plug up.
  • ACID- The Catch-All Filter-Drier is unexcelled in acid removal ability. The hydrochloric, hydrofluoric, and various organic acids are adsorbed and held by the desiccant in a manner similar to the adsorption of moisture. Tests have demonstrated that the Catch-All Filter-Drier has superior acid removal ability when compared to competitive driers. This ability, along with its excellent ability toclean up the oil, is responsible for the excellent field performance in cleaning up severely contaminated systems.
  • OIL SLUDGE AND VARNISH- Even the best refrigeration oils break down to produce varnish, sludge and organic acids. Only the Catch-All Filter-Drier is capable of removing these products of oil decomposition.
  • SPECIAL APPLICATIONS- A special ?HH? core Catch-All Filter-Drier is available to remove wax which frequently causes difficulty on low temperature refrigeration systems. For cap tube systems, use the C-032-CAP or C-032-CAP-T Catch-All which hasfittings suitable for attaching to any size capillary tube.
For Further Technical Specifications Click Here!


WEIGHT 0.72 Pounds (Lb)
WIDTH 2 Inches (In)
HEIGHT 2 Inches (In)
COUNTRY OF ORIGIN USA
UPC OR BARCODE 68747216277
HAZARDOUS MATERIAL No
EPA CERT REQUIRED No
LENGTH 5 Inches (In)
BRAND Sporlan
CONNECTION TYPE ODF
SIZE 3/8"

Customer Review

You Might Also Like