Genteq 5SME39HLHE128 ECM 142R Condenser Fan Motor 1/3 HP 208-230V Variable Speed – Rheem/Ruud 51-102728-13 Closeout
The Genteq 5SME39HLHE128 is a 1/3 HP ECM 142R variable-speed outdoor fan motor. Genteq built it as original equipment for Rheem and Ruud condensers and heat pumps, where it carries Rheem part number 51-102728-13. The motor runs directly on 208-230V single-phase line voltage, and the outdoor unit's control board sets its speed, so fan airflow can follow system demand instead of running flat out all the time. This is new old stock, and it is our last one. It has never been installed and has been on our shelf since it came in. If you want the same Genteq motor your Rheem or Ruud unit left the factory with, this is that motor at a closeout price.
Is the 5SME39HLHE128 the Original Motor in Your Rheem or Ruud Unit?
Rheem and Ruud outdoor units built with the 51-102728-13 ECM fan motor typically carry a Genteq nameplate showing 5SME39HLHE128 and the ECM 142R motor family. If your failed motor shows either number, this Genteq motor matches what came out of the unit. Rheem has since moved this position to newer part numbers. The 51-102728-24 replaced the -13, so either motor may show up in your unit's service history.
Before you buy, check the old nameplate for 1/3 HP, 208-230V and the 5SME39HLHE128 model number. Also compare rotation direction, shaft size, mounting and the connector layout. ECM outdoor fan motors work with the condenser's control board, so it is worth checking the board signal and line voltage before blaming the motor for a fan that won't run.
Ideal for: HVAC techs and Rheem or Ruud owners replacing a failed Genteq 5SME39HLHE128 / Rheem 51-102728-13 variable-speed ECM condenser fan motor with the same original-equipment Genteq motor.
Prefer the current Rheem part number? We also have the Protech 51-102728-24 ECM condenser fan motor, the Rheem replacement for 51-102728-13, also as a new old stock closeout.
Product photo is a stock image for reference only. The actual motor, label and packaging may look different. Fitment information is a general guide only. Always confirm the part number on your existing motor or in the equipment parts list before ordering. This is a single new old stock unit sold as a closeout. Request part-matching help, contact Budget Heating, or call 813-885-7999.
What's Included
| Genteq Model | 5SME39HLHE128 — ECM 142R Outdoor Fan Motor |
|---|---|
| Rheem / Ruud OEM Part | 51-102728-13 |
| Later Rheem Part Number | 51-102728-24 |
| Application | Rheem / Ruud Condenser and Heat Pump Outdoor Fan |
| Horsepower | 1/3 HP |
| Motor Type | ECM, Variable Speed, High-Voltage |
| Electrical | 208-230V, Single Phase |
| Nameplate Speed | 870 RPM |
| Rotation | Counterclockwise |
| Condition | New Old Stock, Never Installed, Closeout, Last Unit |
You receive one Genteq 5SME39HLHE128 ECM condenser fan motor. The fan blade, mounting bracket and wiring harness from your existing unit are not included. ECM motors do not use a run capacitor. This motor takes line voltage plus a speed signal from the outdoor unit's controls, so it connects in place of the original ECM motor using your unit's existing wiring.
Motor Features & Service Notes
Genteq ECM 142R Outdoor Fan Motor
- Genteq original-equipment motor behind Rheem/Ruud 51-102728-13
- ECM 142R motor family built for outdoor condenser fan duty
- 1/3 HP output for residential condensers and heat pumps
- Variable speed set by the outdoor unit's control board
- High-voltage ECM that runs on 208-230V line power
- No separate step-down transformer or run capacitor needed
- 870 RPM nameplate rating
- Counterclockwise rotation to match the factory fan blade
- Quieter outdoor operation at reduced fan speeds
- Lower power draw than a comparable PSC motor at part load
Closeout Buying & Installation Notes
- New old stock, never installed and kept on our shelf
- Last unit available at closeout pricing
- Match 5SME39HLHE128 or 51-102728-13 on your old motor label
- Compare shaft, mounting and connector layout before ordering
- Check line voltage and the control signal before replacing the motor
- Not interchangeable with a PSC condenser fan motor
- Reuse your fan blade if it is straight and balanced
- Set the blade at the original height in the fan orifice
- Installation by a qualified HVAC technician is recommended
- Disconnect all power before servicing the outdoor unit
Specifications & Manuals
Manufacturer documentation for this closeout Genteq ECM motor is not posted. For fitment help with your Rheem or Ruud outdoor unit, contact Budget Heating at 813-885-7999 before ordering.
Frequently Asked Questions
What is the Genteq ECM 142R?
ECM 142R is Genteq's family of electronically commutated motors for outdoor condenser fans. The 5SME39HLHE128 is the 1/3 HP version built as original equipment for Rheem and Ruud outdoor units.
How is the 5SME39HLHE128 related to Rheem 51-102728-13?
5SME39HLHE128 is the Genteq model number on the motor Rheem and Ruud sold under part number 51-102728-13. Rheem's newer 51-102728-24 is listed as the replacement for 51-102728-13.
Should I choose this motor or the Protech 51-102728-24?
Both serve the same Rheem/Ruud ECM outdoor fan position. Choose the 5SME39HLHE128 to match the original Genteq motor exactly, or the 51-102728-24 if you prefer the later Rheem part number. Compare either one with your old motor's rotation, shaft and connectors.
Why doesn't this condenser fan motor use a capacitor?
ECM motors have built-in electronics that control the motor directly, so they don't need the run capacitor a PSC motor uses. If your unit has this motor, any capacitor in the outdoor unit serves the compressor, not the fan.
My ECM condenser fan won't start. Is the motor always the problem?
Not always. A technician should confirm 208-230V at the motor and a speed signal from the control board, and check the harness, before replacing it. A board or wiring fault can look like a dead motor.
Will the Genteq motor I receive match the photo?
It may not. The photo is a stock image. This new old stock motor may carry Genteq, GE or Rheem labeling and packaging different from what's shown.