decor decor

Summary

Product #26014: $525.00
  • Refrigerant Agreement:
  • Upload EPA 608 Certification:
525
$525.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
NU-22B (R-422B) 25 lb Jug | Full Changeover from R-22, R-407C, R-422D & R-417A

Freon Refrigerant NU-22B 25lb jug Freon Refrigerant - (R-22 Replacement)

· SKU 26014
Refrigerant Type
R-422B
Average Rating:
List price: $725.00

Sale price:

$525.00
You save $200.00!
  • SKU: 26014
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • Refrigerant Type:
    R-422B

Maximum file size is 524288KB, file types are bmp, gif, jpg, jpeg, jpe, jif, jfif, jfi, png, wbmp, xbm, tiff, txt, pdf, rtf, doc, docx, xls, xlsx, accdb, mdb, one, pps, ppsx, ppt, pptx, pub, odt, ods, odp, odg, odf

Adding to cart… The item has been added

NU-22B (R-422B) Refrigerant 25 lb Jug — Replacement for R-22, R-407C, R-422D & R-417A

NU-22B, ASHRAE designation R-422B, closely mimics R-22's operating characteristics and pressures. It can completely replace R-22 in new or existing residential and commercial air conditioning systems and in non-flooded evaporator chillers. It also replaces R-407C, R-422D, and R-417A. According to the product information, no product-specific tools or supplies are needed: it is compatible with standard oils and the standard components and materials used in R-22 systems. It is non-flammable, ASHRAE safety class A1, and has zero ozone depletion potential. Purchase requires EPA Section 608 certification.

Is NU-22B the Right R-22 Replacement?

NU-22B is for owners and contractors who want to keep a working R-22 air conditioner or chiller in service on a non-ozone-depleting refrigerant without a major retrofit. The process is a complete changeover: evacuate the old R-22, then charge the system with NU-22B.

Important: NU-22B cannot be added to R-22. The system must be fully evacuated and recharged with NU-22B. If you need a replacement that can be topped off, see Freon™ MO99 (R-438A).

Ideal for: Converting R-22, R-407C, R-422D, or R-417A residential and commercial AC systems and non-flooded evaporator chillers.

Still need straight R-22? The R-22 30 lb jug is available for systems staying on R-22.

Refrigerant purchases require the Refrigerant Agreement and proof of EPA Section 608 certification. Conversion results depend on system design and the equipment manufacturer's recommendations. For use by qualified HVAC/R technicians. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Refrigerant NU-22B (ASHRAE R-422B)
Net Weight 25 lb
Replaces R-22, R-407C, R-422D, R-417A
Application Residential & commercial AC, non-flooded evaporator chillers
Operating Pressures Similar to R-22
Safety Class ASHRAE A1, non-flammable
Ozone Depletion Zero ODP
Mixing with R-22 Not allowed; fully evacuate and recharge

A 25 lb supply of R-422B for a complete changeover from R-22 and other older blends.

Refrigerant & Changeover Features

NU-22B (R-422B)

  • Closely mimics R-22 operating characteristics
  • R-22 operating pressures
  • Greater capacity than R-417A
  • Non-flammable, ASHRAE A1
  • Non-toxic
  • Zero ozone depletion potential
  • For OEM and service replacement
  • In use in thousands of installations
  • Replaces R-407C, R-422D, and R-417A
  • 25 lb jug for full system charges

Changeover Notes

  • Evacuate the old refrigerant completely
  • Do not mix with R-22
  • Compatible with all standard oils
  • No product-specific tools required
  • Works with standard R-22 system components
  • For residential and commercial AC
  • For non-flooded evaporator chillers
  • Label the system with the new refrigerant
  • Use certified recovery equipment
  • For qualified HVAC/R technicians

Frequently Asked Questions

Can I top off an R-22 system with NU-22B?

No. NU-22B cannot be added to R-22. Fully evacuate the R-22, then charge the system with NU-22B.

Do I have to change the oil to use NU-22B?

According to the product information, NU-22B is compatible with all standard oils used in R-22 systems, so no oil replacement is required. Follow the equipment manufacturer's guidance.

What is the ASHRAE number for NU-22B?

NU-22B is ASHRAE R-422B, safety classification A1 (non-flammable, lower toxicity).

Can NU-22B replace R-407C or R-417A?

Yes. NU-22B replaces R-22, R-407C, R-422D, and R-417A, and it offers greater capacity than R-417A.

Can NU-22B be used in a flooded evaporator chiller?

NU-22B is listed for non-flooded evaporator chillers. Consult the chiller manufacturer for flooded evaporator designs.

What else is needed for a clean changeover?

Use certified recovery equipment and a recovery cylinder such as the 30 lb recovery cylinder. Many techs also install a new liquid line filter drier.

Customer Review