NU-22B (R-422B) Refrigerant 25 lb Jug — Replacement for R-22, R-407C, R-422D & R-417A
NU-22B, ASHRAE designation R-422B, closely mimics R-22's operating characteristics and pressures. It can completely replace R-22 in new or existing residential and commercial air conditioning systems and in non-flooded evaporator chillers. It also replaces R-407C, R-422D, and R-417A. According to the product information, no product-specific tools or supplies are needed: it is compatible with standard oils and the standard components and materials used in R-22 systems. It is non-flammable, ASHRAE safety class A1, and has zero ozone depletion potential. Purchase requires EPA Section 608 certification.
Is NU-22B the Right R-22 Replacement?
NU-22B is for owners and contractors who want to keep a working R-22 air conditioner or chiller in service on a non-ozone-depleting refrigerant without a major retrofit. The process is a complete changeover: evacuate the old R-22, then charge the system with NU-22B.
Important: NU-22B cannot be added to R-22. The system must be fully evacuated and recharged with NU-22B. If you need a replacement that can be topped off, see Freon™ MO99 (R-438A).
Ideal for: Converting R-22, R-407C, R-422D, or R-417A residential and commercial AC systems and non-flooded evaporator chillers.
Still need straight R-22? The R-22 30 lb jug is available for systems staying on R-22.
Refrigerant purchases require the Refrigerant Agreement and proof of EPA Section 608 certification. Conversion results depend on system design and the equipment manufacturer's recommendations. For use by qualified HVAC/R technicians. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Refrigerant | NU-22B (ASHRAE R-422B) |
|---|---|
| Net Weight | 25 lb |
| Replaces | R-22, R-407C, R-422D, R-417A |
| Application | Residential & commercial AC, non-flooded evaporator chillers |
| Operating Pressures | Similar to R-22 |
| Safety Class | ASHRAE A1, non-flammable |
| Ozone Depletion | Zero ODP |
| Mixing with R-22 | Not allowed; fully evacuate and recharge |
A 25 lb supply of R-422B for a complete changeover from R-22 and other older blends.
Refrigerant & Changeover Features
NU-22B (R-422B)
- Closely mimics R-22 operating characteristics
- R-22 operating pressures
- Greater capacity than R-417A
- Non-flammable, ASHRAE A1
- Non-toxic
- Zero ozone depletion potential
- For OEM and service replacement
- In use in thousands of installations
- Replaces R-407C, R-422D, and R-417A
- 25 lb jug for full system charges
Changeover Notes
- Evacuate the old refrigerant completely
- Do not mix with R-22
- Compatible with all standard oils
- No product-specific tools required
- Works with standard R-22 system components
- For residential and commercial AC
- For non-flooded evaporator chillers
- Label the system with the new refrigerant
- Use certified recovery equipment
- For qualified HVAC/R technicians
Frequently Asked Questions
Can I top off an R-22 system with NU-22B?
No. NU-22B cannot be added to R-22. Fully evacuate the R-22, then charge the system with NU-22B.
Do I have to change the oil to use NU-22B?
According to the product information, NU-22B is compatible with all standard oils used in R-22 systems, so no oil replacement is required. Follow the equipment manufacturer's guidance.
What is the ASHRAE number for NU-22B?
NU-22B is ASHRAE R-422B, safety classification A1 (non-flammable, lower toxicity).
Can NU-22B replace R-407C or R-417A?
Yes. NU-22B replaces R-22, R-407C, R-422D, and R-417A, and it offers greater capacity than R-417A.
Can NU-22B be used in a flooded evaporator chiller?
NU-22B is listed for non-flooded evaporator chillers. Consult the chiller manufacturer for flooded evaporator designs.
What else is needed for a clean changeover?
Use certified recovery equipment and a recovery cylinder such as the 30 lb recovery cylinder. Many techs also install a new liquid line filter drier.