decor decor

Summary

Product #172931: $11,570.00
  • Crating :
  • Roof Curb :
  • Curb Adapter :
  • Economizer or Fresh Air Damper :
  • Natural Gas or Liquid Propane Kit:
11570
$11,570.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?

8.5 Ton Rheem R454B 11 EER 460V 3Ph 150K BTU Gas Package Unit, RGEDYB102ADG152AAAA0

· SKU 172931 · AHRI 215817096 · Package AC
Capacity
102,000 BTU
Refrigerant
R-454B
Average Rating:
List price: $15,617.00

Sale price:

$11,570.00
You save $4,047.00!
  • SKU: 172931
  • Availability:
    Usually Ships in 7 to 10 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • Product Type:
    Package AC
  • Tonnage:
    8.5
  • Operating Mode:
    Gas
  • Refrigerant Type:
    R-454B
  • Airflow Direction:
    Downflow/Horizontal
  • Voltage:
    460V 3PH
Crating
  • Crating
Roof Curb
  • 7.5 - 12.5 Ton Rheem 14" Roof Curb ALL Models, RXKG-DDD14
Curb Adapter
Economizer or Fresh Air Damper
  • 7.5 - 12.5 Ton Rheem Downflow Economizer, RXRD-11MDDAM3
  • 7.5 - 12.5 Ton Rheem Horizontal Economizer, RXRD-01MDHBM3
  • Rheem LP Kit for RGED Gas Package, RXGJ-FP39
Adding to cart… The item has been added

Rheem 8.5 Ton R-454B Gas/Electric Package Unit, 150,000 BTU/h Heat — RGEDYB102ADG152AAAA0

The Rheem RGEDYB102ADG152AAAA0 is a 8.5-ton Commercial Renaissance Classic Series packaged gas/electric unit that combines R-454B air conditioning with two-stage natural gas heat in one medium-commercial rooftop cabinet. Wired for 460V 3-phase power, it delivers 96,000 BTU/h AHRI net cooling at 11.0 EER / 14.6 IEER and pairs it with a 150,000 BTU/h nominal, two-stage gas furnace (121,500 BTU/h output at 81% steady-state efficiency). Built around a two-stage scroll compressor, all-microchannel coils, factory refrigerant leak detection, and a belt-drive blower with a standard variable frequency drive (VFD), this convertible downflow/horizontal unit is a complete heating-and-cooling package for larger commercial buildings that want standard gas heat from a single 460V 3-phase rooftop.

Is a 8.5-Ton / 150,000 BTU Gas Package Unit the Right Size?

This unit matches 96,000 BTU/h of net cooling with a 150,000 BTU/h gas furnace, so it must be sized for two loads at once. On cooling, 8.5 tons typically suits roughly 3,400 to 5,100 sq ft of commercial space; on heating, the 121,500 BTU/h output (standard heat) should be matched to the building's design heating load and climate.

Cooling load depends on occupancy, ventilation, glazing, insulation, and local design temperatures, while heating load depends on climate, envelope, and ventilation air. The furnace is two-stage with 6 burners; first stage runs near 70% of full fire (about 85,050 BTU/h output) for quieter, more even heat, and the standard VFD supply fan improves part-load efficiency. Size both sides from an engineered commercial load calculation rather than floor area alone.

Ideal for: Big retail and showroom floors, high-occupancy restaurants, worship halls, and larger offices on 460V 3-phase power, needing dependable two-stage gas heat.

Cooling only? If you don't need gas heat, the 8.5-ton RACD 460V 3-phase straight-air package unit is the cooling-only equivalent. Compare 8.5-ton 150,000 BTU heat, 208/230V 3-phase.

Recommended applications are general guidelines only. Actual cooling and heating requirements depend on insulation, ventilation, occupancy, solar gain, climate, and design temperatures. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Model Number RGEDYB102ADG152AAAA0
Product Type Commercial Renaissance Classic Series Packaged Gas/Electric Unit
Nominal Cooling 8.5 Tons — 96,000 BTU/h AHRI net cooling
Cooling Efficiency 11.0 EER / 14.6 IEER
Gas Heating 150,000 BTU/h nominal input — 121,500 BTU/h output (81% steady-state, two-stage, 6 burners)
Heat Exchanger Two-stage, direct spark ignition (10-year warranty; stainless-steel option available)
Refrigerant R-454B (A2L, factory charged — approx. 114 oz)
Compressor Single Two-Stage Scroll Compressor
Nominal Airflow 3,400 CFM — belt-drive blower with standard VFD, convertible downflow or horizontal
Electrical 460V, 3-Phase, 60 Hz
Minimum Circuit Ampacity 22 A
Max Overcurrent Protection 30 A
Manufacturer Warranty 5-Year Compressor / 10-Year Heat Exchanger / 1-Year Parts (Commercial)

The RGEDYB102ADG152AAAA0 ships as one factory-assembled, wired, and run-tested cabinet with R-454B charged and the gas furnace installed — set it, connect power, gas, and ducting, and commission. Convert to propane with the RXGJ-FP39 LP conversion kit. Need cooling only? See the matching 8.5-ton RACD straight-air unit, browse more Rheem equipment, or the full packaged unit lineup.

Unit Features

Cooling, Compressor & Coils

  • Single two-stage scroll compressor factory-charged with low-GWP R-454B refrigerant
  • Two stages of cooling for part-load operation, quieter running, and improved humidity control
  • MicroChannel outdoor and indoor coils with TXV metering and a solid-core filter drier
  • Factory-installed A2L refrigerant leak detection with automatic mitigation
  • Rated 11.0 EER / 14.6 IEER at 96,000 BTU/h AHRI net cooling
  • High- and low-pressure protection with Smart Logic and internal compressor overload
  • Cooling operation to 125°F ambient; convertible downflow or horizontal airflow
  • Heavy galvanized cabinet with forkable base rails and gasket-protected panels

Gas Heat, Controls & Serviceability

  • Two-stage natural gas heat — 150,000 BTU/h nominal input, 121,500 BTU/h output at 81% steady-state efficiency
  • Durable two-stage gas heat exchanger with 6 burners and direct spark ignition (10-year warranty; stainless-steel exchanger available)
  • First-stage heat near 70% of full fire (~85,050 BTU/h) for even comfort; field-convertible to LP with the Rheem RXGJ-FP39 kit
  • Belt-drive supply fan delivering 3,400 nominal CFM with a standard Variable Frequency Drive (VFD)
  • CoreCommand control with PlusOne diagnostics and dual 7-segment LED display
  • Pre-wired for a field- or factory-installed economizer (free cooling)
  • 460V, 3-Phase, 60 Hz power: 22 A minimum circuit ampacity, 30 A maximum overcurrent protection
  • Ships wired and run-tested; 0.75 in. gas connection; MERV filters available

Specifications & Manuals

Product documentation includes RGED series technical specifications, installation instructions, and warranty information to assist with equipment selection, installation, and service. This unit carries a Rheem limited warranty; see the warranty document above for full coverage terms.

Frequently Asked Questions

What cooling and heating capacity does the RGEDYB102ADG152AAAA0 provide?

It delivers 96,000 BTU/h AHRI net cooling (11.0 EER / 14.6 IEER) and 121,500 BTU/h of gas heating output from a 150,000 BTU/h nominal, two-stage furnace at 81% steady-state efficiency. Size both sides from an engineered commercial load calculation.

What power does the RGEDYB102ADG152AAAA0 require?

It is wired for 460V, 3-Phase, 60 Hz and, on the standard VFD-Medium drive, needs a 22 A minimum circuit ampacity with a 30 A maximum overcurrent protection device. If your panel is 208/230V, order the 208/230V version instead.

Is the furnace two-stage, and can it run on propane?

Yes. The gas furnace is two-stage with 6 burners and direct spark ignition; first stage runs near 70% of full fire. It ships for natural gas and can be field-converted to LP (propane) with the Rheem RXGJ-FP39 LP conversion kit for RGED gas packs.

Does the VFD supply fan come standard?

Yes. A variable frequency drive on the belt-drive supply fan is standard on every RGEDYB unit. It ramps the fan smoothly and runs at reduced speed at part load for lower energy use, quieter operation, and better dehumidification.

Can this unit be installed downflow and horizontal?

Yes. Airflow is field-convertible between vertical downflow (for curbed rooftop openings) and horizontal side-flow, so the same unit works on a curb or a slab with side duct connections.

Why choose the 150,000 BTU/h gas-heat option?

The 150,000 BTU/h furnace provides 121,500 BTU/h of standard heating output. Match the gas-heat size to your climate and design heating load.

Customer Review