decor decor

Summary

Product #172894: $6,570.00
  • Crating :
  • Heat Strip:
  • Roof Curb :
  • Curb Adapter :
  • Economizer or Fresh Air Damper :
6570
$6,570.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?

6 Ton Rheem R454B 11.2 EER2 460V 3Ph Straight Air Package Unit, RACCYB072ADT000AAAA0

· SKU 172894 · AHRI 214803100 · Package AC
Capacity
72,000 BTU
Refrigerant
R-454B
Average Rating:
List price: $8,867.00

Sale price:

$6,570.00
You save $2,297.00!
  • SKU: 172894
  • Availability:
    Usually Ships in 3 to 5 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • Product Type:
    Package AC
  • Tonnage:
    6
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-454B
  • Airflow Direction:
    Downflow/Horizontal
  • Voltage:
    460V 3PH
Crating
  • Crating
  • 15kW Rheem RACB Commercial 460V 3Ph Heat Strip, RXJJ-DC15DNV
  • 20kW Rheem RACB Commercial 460V 3Ph Heat Strip, RXJJ-DC20DNV
Roof Curb
  • 3 - 6 Ton Rheem 14" Roof Curb ALL Models, RXKG-DCC14
Curb Adapter
Economizer or Fresh Air Damper
  • 3-6 Ton Rheem RGEC Manual Fresh Air Damper, RXRF-ACA1
  • 3-6 Ton Rheem RGEC Motorized Fresh Air Damper, RXRF-ACB1
  • 3-6 Ton Rheem RGEC Horizontal Economizer w/ Single Enthalpy, RXRD-01MCHAM3
  • 3-6 Ton Rheem RGEC Downflow Economizer w/ Single Enthalpy, RXRD-01MCDAM3
Adding to cart… The item has been added

Rheem 6 Ton R-454B Commercial Packaged Air Conditioner — RACCYB072ADT000AAAA0

The Rheem RACCYB072ADT000AAAA0 is the 460V three-phase build of Rheem's 6-ton Commercial Classic Series package unit, delivering 68,500 BTU/h of AHRI net cooling at 11.2 EER and 14.8 IEER on R-454B refrigerant. Like the 208/230V 6-ton, it carries a two-stage scroll compressor for part-load efficiency and improved dehumidification, but its 460V wiring cuts rated compressor amperage to about half, easing branch-circuit and feeder sizing when multiple large rooftop units share one 460V service. It keeps the 2,400 CFM blower, microchannel coils, and convertible downflow/horizontal design.

Is a 6-Ton Package Unit the Right Size?

As the top capacity in the RACCYB line, this 6-ton unit is matched to loads approaching 68,000 to 72,000 BTU/h, often roughly 2,400 to 3,600 sq ft of commercial space. Its two-stage compressor also helps in spaces where the load varies through the day, since it can hold a lower stage for much of the time rather than cycling a single fixed stage on and off.

Even at 6 tons, load drivers such as high occupancy, large glazing, make-up air, and cooking or process heat determine whether this is the right unit or whether the space needs more than one system. The two-stage compressor gives some tolerance for varying loads, but it is not a substitute for a real load calculation. Sizing from a commercial load analysis keeps staging effective and avoids the humidity problems that come with a grossly oversized single unit.

Ideal for: Large commercial and institutional zones in facilities with 460V three-phase power, where several big rooftop units share one service and lighter branch-circuit wiring is an advantage.

Need more capacity? Need more than 6 tons? Move up to Rheem's larger commercial rooftops, such as the 7.5-Ton Rheem three-phase package unit, or browse the full packaged air conditioner category.

Recommended applications are general guidelines only. Actual capacity requirements depend on insulation, ventilation, occupancy, solar gain, ceiling height, and local design temperatures. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Model Number RACCYB072ADT000AAAA0
Product Type Commercial Classic Series Straight-Air (Cooling-Only) Packaged Air Conditioner
Nominal Capacity 6 Tons — 72,000 BTU/h (68,500 BTU/h AHRI net cooling)
Rated Efficiency 11.2 EER / 14.8 IEER
Refrigerant R-454B (A2L, factory charged — approx. 85 oz)
Compressor Two-stage scroll compressor
Nominal Airflow 2,400 CFM — convertible downflow or horizontal
Electrical 460V, 3-Phase, 60 Hz
Minimum Circuit Ampacity 18 A
Max Overcurrent Protection 25 A
Manufacturer Warranty 5-Year Compressor / 1-Year Parts (Commercial)

The RACCYB072ADT000AAAA0 ships as one factory-assembled, wired, and run-tested cabinet, so there is no field refrigerant line set to braze — it arrives charged with R-454B and ready to set, connect power and ducting, and commission. For curbed rooftop installs, pair it with the matching 3–6 Ton Rheem 14 in. roof curb (RXKG-DCC14). Browse more Rheem equipment or the full packaged air conditioner lineup for related sizes and voltages.

Unit Features

Cooling, Compressor & Coils

  • Two-stage scroll compressor factory-charged with low-GWP R-454B refrigerant
  • Two-stage scroll compressor for part-load operation, quieter running, and improved humidity control
  • MicroChannel outdoor condenser coil and MicroChannel indoor evaporator coil for efficient heat transfer and reduced refrigerant charge
  • TXV (thermostatic expansion valve) refrigerant metering with a solid-core liquid-line filter drier
  • Factory-installed A2L refrigerant leak detection system with automatic mitigation
  • Rated 11.2 EER / 14.8 IEER at 72,000 BTU/h nominal (68,500 BTU/h AHRI net) cooling
  • High- and low-pressure protection with built-in Smart Logic and internal compressor overload
  • Cooling operation to 125°F ambient; ships wired and run-tested
  • 18-gauge galvanized cabinet with forkable base rails and gasket-protected panels

Airflow, Controls & Serviceability

  • Convertible airflow — vertical downflow or horizontal side-flow — delivering 2,400 nominal CFM
  • Direct-drive ECM indoor blower with multiple selectable speed taps
  • PlusOne ServiceSmart access: Qwik-Change Flex-Fit filter rack, Qwik-Slide blower assembly, and Qwik-Clean composite drain pan
  • PlusOne Diagnostics with dual 7-segment LED display and standard Modbus interface
  • Overflow condensate sensor and external lockable gauge ports
  • Ships with four disposable 2 x 16 x 16 in. filters; MERV 8 and MERV 13 filters available as field accessories
  • 460V, 3-Phase, 60 Hz power: 18 A minimum circuit ampacity, 25 A maximum overcurrent protection, compressor RLA 9.1 A
  • Field-installed accessories include economizers, roof curbs, hail guards, disconnects, and low-ambient control

Specifications & Manuals

Product documentation includes RACC series technical specifications, installation instructions, and warranty information to assist with equipment selection, installation, and service. This unit carries a Rheem limited warranty; see the warranty document above for full coverage terms and conditions.

Frequently Asked Questions

What size space will the RACCYB072ADT000AAAA0 cool?

It is matched to commercial cooling loads around 72,000 BTU/h (68,500 BTU/h AHRI net), which often lands near roughly 2,400 to 3,600 sq ft of light-commercial space. Because occupancy, ventilation, glazing, and internal heat gain move the real load, confirm the size with a commercial load calculation rather than floor area alone.

Why choose the 460V RACCYB072ADT000AAAA0 over the 208/230V model?

On 460V, 3-Phase, 60 Hz this unit draws about half the amperage of the 208/230V build — a 18 A minimum circuit ampacity and 25 A maximum overcurrent protection, with a compressor RLA of 9.1 A. That eases wiring and breaker sizing where a 460V service feeds several units. If your panel is 208/230V, order the 208/230V three-phase 6-ton version instead.

Is this unit charged with R-454B, and does it have leak detection?

Yes. The RACCYB072ADT000AAAA0 is factory-charged with low-GWP R-454B (an A2L refrigerant) and includes a factory-installed refrigerant leak detection system that triggers a fault and mitigation sequence if a leak is sensed. Refrigerant charge is approximately 85 oz.

Can this package unit be installed downflow and horizontal?

Yes. Airflow is field-convertible between vertical downflow (for roof-curb installations) and horizontal side-flow, so the same unit works on a curbed rooftop opening or a slab with ducted side connections. A matching 14 in. Rheem roof curb (RXKG-DCC14) is available for 3–6 ton units.

Does this unit provide heat?

This is a cooling-only (straight-air) package air conditioner. Electric resistance heater kits are available as field- or factory-installed accessories on the RACC platform; if you need heating built in, a gas/electric or heat-pump package unit is the better starting point.

What makes the 6-ton RACCYB different from the 3–5 ton models?

Besides its higher 68,500 BTU/h AHRI net capacity and 2,400 CFM blower, the 6-ton RACCYB uses a two-stage scroll compressor, while the 3-, 4-, and 5-ton RACCYB units use a single-stage scroll. Two-stage operation lets it run at a lower stage for much of the season, improving part-load quietness and humidity control. Note that 6-ton commercial units are rated in EER/IEER (11.2 EER / 14.8 IEER) rather than SEER2.

Customer Review

You Might Also Like