decor decor
W5AM61M21XA | Five Tons Squeezed Into Twenty-One Inches

5 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM61M21XA

· SKU 180442 · Cased Coil
Capacity
60,000 BTU
Refrigerant
R-454B
Average Rating:
List price: $2,110.00

Sale price:

$1,620.00
You save $490.00!
  • SKU: 180442
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • Product Type:
    Cased Coil
  • Tonnage:
    5
  • Refrigerant Type:
    R-454B
  • Airflow Direction:
    Multi-Position
  • Cabinet Width:
    21”
Adding to cart… The item has been added

5 Ton EcoTemp R-454B Multi-Positional Cased Coil, W5AM61M21XA

Five tons of capacity through a 21 in. wide cabinet is an unusual combination, and the W5AM61M21XA exists precisely for the jobs where 24-1/2 in. will not go. It carries the 61-size coil on a 35 in. tall, 21 in. wide casing, holds the full 1500 to 2500 CFM airflow rating, and measures 82.6 MBH gross at 2000 CFM. Everything else follows the W5AM standard: factory-installed R-454B TXV, 7/8 in. suction and 3/8 in. liquid connections, dual sloped FRTP drain pans, factory UV knockouts and the complete A2L leak dissipation system.

Is a 5 Ton Cased Coil the Right Size?

The load side of this decision is the same as any 5 ton system — roughly 2,600 to 3,500 sq. ft. of residential space, or a light commercial suite on a split system. What makes the 6121 a distinct product is the fit. A 21 in. casing is 3-1/2 in. narrower than the standard 5 ton coil, which is often the difference between a coil that goes into an existing closet and one that means framing work.

That narrower face does come with a tradeoff: less coil area presented to the airstream means higher air-side pressure drop than a 24-1/2 in. coil at the same CFM. When the system is designed for 2500 CFM, that matters. Read the static pressure drop table for size 6121 against the blower's published performance before committing, and verify the AHRI-certified pairing with your outdoor unit. Where the width is genuinely available, the wider coil is the easier system to move air through.

Ideal for: 5 ton installations in 21 in. closets and chases, retrofits where the existing cabinet cannot be widened, upstairs mechanical rooms with tight framing, and any job where a 24-1/2 in. coil is dimensionally out of reach.

Need the wider cabinet? The 5 Ton EcoTemp W5AM61M24XA Cased Coil carries the same 61-size coil in a full 24-1/2 in. casing for lower air-side pressure drop.

Recommended applications are general guidelines only. Actual coil selection depends on the AHRI-certified system match, blower capability, duct static, and local design conditions. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Model Number W5AM61M21XA — 5 Ton Narrow-Cabinet Multi-Poise Cased Evaporator Coil
Nominal Capacity 5 Ton / 60,000 BTUH
Coil Type Vertical A-Coil, Cased
Airflow Configuration Multi-Poise — Upflow, Downflow, Horizontal-Left, Horizontal-Right
Refrigerant R-454B Only
Cabinet Width 21 in.
Cabinet Height 35 in.
Suction Line Connection 7/8 in. Sweat
Liquid Line Connection 3/8 in. Sweat
Metering Device Factory-Installed R-454B TXV
Rated Airflow Range 1500 – 2500 CFM
Operating Weight 89.0 lb
Leak Dissipation Complete A2L Dissipation System Included
Warranty 5-Year Parts Limited; 10-Year with Registration Within 90 Days

Outdoor pairing follows the 5 ton line: the EcoTemp W5A5S60AKAWA condenser or the W5H5S60AKAAA heat pump. If the furnace beneath is not 21 in., the ICP coil adapter kits (NAHB00101CA, NAHB00201CA, NAHB00301CA) handle no-offset, single-offset and double-offset transitions. See the rest of the range on the 4 to 5 ton cased coil page.

Cabinet & Coil Features

W5AM61M21XA Cabinet & Construction

  • 21 in. casing width — 3-1/2 in. narrower than the standard 5 ton coil
  • 35 in. tall body, 23.4 in. deep
  • 89.0 lb operating weight, 3 lb lighter than the 24-1/2 in. models
  • 24-gauge pre-painted taupe metallic steel
  • Foil-faced R-2.1 insulation for quiet operation at high airflow
  • Two FRTP condensate pans, vertical and horizontal, both sloped
  • Primary and secondary 3/4 in. FPT drain connections
  • Factory-installed UV knockouts
  • 100.0 lb shipping weight
  • Ships 35.8 in. high by 21.6 in. wide by 23.4 in. deep

W5AM61M21XA Coil, Metering & Installation

  • 82.6 MBH gross at 2000 CFM, 67°F EWB, 45°F SST
  • Full 1500 to 2500 CFM rating in the narrow cabinet
  • Factory-installed R-454B specific thermostatic expansion valve
  • 7/8 in. suction, 3/8 in. liquid sweat connections
  • Straight tube stub-outs for braze-less compression fittings
  • Side tubing routing preserving coil cleaning and TXV access
  • Refrigerant sensor and wire harness factory installed
  • Dissipation board, housing and power harness supplied in the parts box
  • 2100 psi minimum burst pressure, split delta plate service access
  • AHRI rated, UL and c-UL listed

Specifications & Manuals

Compare the size 6121 and 6124 static pressure drop rows before finalizing blower selection — the narrower cabinet runs higher air-side resistance at the same airflow. Dimensional data, capacity tables and full warranty terms are in the attached documents.

Frequently Asked Questions

Can a 5 ton coil really fit a 21 in. wide closet?

Yes. The W5AM61M21XA is a nominal 5 ton coil in a 21 in. wide, 35 in. tall casing. It is the narrowest 5 ton option in the W5AM line, built specifically for spaces that cannot accept 24-1/2 in.

How does it compare with the 24-1/2 in. 5 ton coils?

Capacity and airflow rating are effectively the same. The narrower coil face means higher air-side pressure drop at a given CFM, and the cabinet weighs about 3 lb less. Choose the wider coil when the space allows it.

What is the height of the 6121 cabinet?

35 in. tall, the same as both 24-1/2 in. five-ton coils, shipping in a 35.8 in. carton. The width is what changes, not the height, so vertical clearance still has to be checked.

What line sizes does the W5AM61M21XA use?

7/8 in. suction and 3/8 in. liquid, both sweat connections, the same as every 3.5 ton and larger coil in the series.

Does the narrow cabinet change the airflow rating?

No. The rated range is still 1500 to 2500 CFM with capacity published at all three points. What changes is how hard the blower works to get there, which is why the static pressure drop table matters on this size.

Is this a direct swap for an older 21 in. R-410A coil?

Not directly. The cabinet may line up, but R-454B is a different refrigerant with a refrigerant-specific TXV and a mandatory A2L dissipation system. The outdoor unit, line set condition and electrical for the dissipation board all have to be addressed as part of a full system changeout.

 
 
 

 
 