decor decor

Summary

Product #180495: $5,830.00
  • Natural or Liquid Propane (LP) Gas:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 42065 / 5 Ton EcoTemp R454B Condenser W5A5S60AKAWA (179441) -- 1
  • 47031 / 5 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM61M21XA (180442) -- 1
  • 47148 / EcoTemp 95% Single Stage 100K BTU Gas Furnace, WFSX100C060B (180479) -- 1
5830
$5,830.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
W5A5S60AKAWA, W5AM61M21XA, WFSX100C060B | 5 ton cooling capacity with a 21-inch 100K furnace

5 Ton EcoTemp 14.5 SEER2 95% AFUE 100K BTU Single Stage Gas System W5A5S60AKAWA, W5AM61M21XA, WFSX100C060B

· SKU 180495 · AHRI 215198025 · Split System
SEER2
14.5
Capacity
60,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $7,580.00

Sale price:

$5,830.00
You save $1,750.00!
  • SKU: 180495
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14.5
  • Product Type:
    Split System
  • Tonnage:
    5
  • Operating Mode:
    Gas
  • Refrigerant Type:
    R-454B
  • AFUE %:
    95
  • Airflow Direction:
    Multi-Position
  • Cabinet Width:
    21"
  • Manufacturer Warranty:
    10 Years
  • BTUs:
    100,000
  • EcoTemp (ICP) Natural Gas to Liquid Propane 90%+ LP Kit, AGAGC9NPS01E
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 1 1/8 & 3/8
  • Copper Line Set 50' 1 1/8 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 5 Ton EcoTemp 14.3 SEER2 R454B Condenser W5A5S60AKAWA
  • 5 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM61M21XA
  • EcoTemp 95% Single Stage 100K BTU Gas Furnace, WFSX100C060B
Adding to cart… The item has been added

EcoTemp 5 Ton 14.5 SEER2 Air Conditioner & 100K BTU Gas Furnace – 21" Cabinet System

This package delivers the line's maximum 60,000 BTU of cooling while keeping the indoor equipment at 21 in. wide. The W5A5S60AKAWA 5 ton R-454B condenser and W5AM61M21XA coil are AHRI-certified at 14.5 SEER2 (AHRI 215198025). The WFSX100C060B furnace provides 97,000 BTU of heat at up to 96.3% AFUE. It's designed for large homes in hot climates such as Florida, Texas, Arizona, and the Gulf Coast, where 5 tons of cooling is the priority and winter heat needs stay within what a 100K furnace delivers.

Is a 5 Ton System with a 100K Furnace the Right Size?

Five tons is the largest single residential split-system size and is often applied to homes of roughly 2,400 to 3,000 square feet, or smaller homes with very high solar gain. Pairing it with the 21 in. 100K furnace makes sense where cooling is the dominant load and a 116,000 BTU furnace would be more heat than the house needs.

A 5 ton system typically calls for around 2,000 CFM of cooling airflow, which is demanding on ductwork. Return-air layout, filter size, and supply trunk sizing all need to support it. Some large homes are better served by two smaller zoned systems. A Manual J load calculation and a duct design review will show whether one 5 ton system is the right approach.

Ideal for: Large Sun Belt homes, two-story homes with heavy cooling loads, open-plan homes with large glass areas, and 5 ton replacements in 21 in. furnace locations.

Need more capacity? For more winter heat, choose the EcoTemp 5 Ton 120K BTU Gas System (WFSX120D066B).

Recommended applications are general guidelines only. Actual system requirements depend on insulation, ductwork, climate, elevation, and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condenser W5A5S60AKAWA — 5 Ton Single-Stage R-454B Air Conditioner
Indoor Coil W5AM61M21XA — 5 Ton Multipoise Cased A-Coil, 21" Wide, Factory TXV
Gas Furnace WFSX100C060B — 100,000 BTU Input / 97,000 BTU Output Condensing Furnace
Furnace Cabinet Width 21" (35" tall)
Cooling Efficiency 14.5 SEER2 (AHRI 215198025)
Heating Efficiency 96.3% AFUE Upflow & Horizontal / 95% AFUE Downflow
Refrigerant R-454B
Compressor Single-Stage Scroll Compressor
Condenser Electrical 208/230V, Single Phase, 60 Hz — 31.1 MCA, 50A Max Fuse/Breaker
Furnace Electrical 115V, Single Phase, 60 Hz — 16.7 Unit Ampacity, 20A Breaker
Manufacturer Warranty 10-Year Parts with Timely Registration; 20-Year Furnace Heat Exchanger

The 5 ton condenser and the 5 ton-family W5AM61M21XA coil both connect to the 21 in. WFSX100C060B furnace, whose blower reaches up to 2,145 CFM in cooling. The coil is 35 in. tall, for a combined stack of about 70 in. The 5 ton W5A5S is rated with a 1-1/8 in. vapor line even though its service valve is 7/8 in., so check the line set before reusing existing copper. You can compare the other 5 ton 92%+ AFUE gas furnace systems.

Condenser, Coil & Furnace Features

W5A5S60AKAWA Condenser & W5AM61M21XA Coil

  • 60,000 BTU scroll compressor rated 23.7 RLA
  • Largest W5A5S fan motor: 1/4 HP, 1,100 RPM, moving 3,900 CFM
  • 22.0 sq. ft. two-row condenser coil with nine circuits
  • 7.9 lb factory R-454B charge for 15 ft of line set
  • Rated with a 1-1/8 in. vapor line and 3/8 in. liquid line
  • 11°F subcooling charging target with the TXV coil
  • W5AM61M21XA: 35 in. tall, 21 in. wide, about 89 lb
  • Factory TXV and a complete A2L dissipation kit
  • Corrosion-resistant FRTP vertical and horizontal drain pans
  • UL and c-UL listed coil with AHRI-certified performance

WFSX100C060B 100K BTU Condensing Furnace

  • 97,000 BTU output at up to 96.3% AFUE
  • 21 in. "C" cabinet, 35 in. tall, about 167 lb
  • 1 HP ECM blower with a cooling range up to 2,145 CFM
  • Heating blower off-delay adjustable to 90, 120, 150, or 180 seconds
  • Five burners and a redundant White-Rodgers gas valve
  • Flame roll-out sensors and a high-temperature limit
  • Upflow, downflow, or horizontal left or right
  • Twelve venting configurations including direct vent
  • Meets ENERGY STAR 5.0 South criteria
  • Approved for twinning with the manufacturer's kit

Specifications & Manuals

Documentation includes condenser, coil, and furnace product data, installation instructions, line-set and venting tables, wiring diagrams, and warranty terms for selection, installation, and service.

Frequently Asked Questions

Why pair a 100K furnace with a 5 ton air conditioner?

In hot climates the cooling load sets the system size, and 97,000 BTU of heat is often more than enough for winter. Choosing the 100K keeps the furnace at 21 in. wide and avoids extra heat that a single-stage furnace would short-cycle.

Why is the rated vapor line larger than the condenser's service valve?

The W5A5S60AKAWA has a 7/8 in. vapor service valve but is rated with a 1-1/8 in. vapor line to limit capacity loss and keep oil returning to the compressor. See the vapor line sizing table in the W5A5S specifications.

What electrical service does the 5 ton condenser require?

A 208/230V single-phase circuit with a 31.1 minimum circuit ampacity and a 50 amp maximum time-delay fuse or breaker. The 24V control circuit requires an external 24V source, typically the furnace transformer.

What subcooling should a 5 ton W5A5S be charged to?

The specifications list 11°F of required subcooling for the 5 ton size with a TXV indoor coil, the highest target in the W5A5S range.

Can the heating blower run longer after the burners shut off?

Yes. The WFSX heating blower off-delay is adjustable to 90, 120 (factory setting), 150, or 180 seconds to pull remaining heat from the heat exchanger.

Can a 21-inch furnace move enough air for 5 tons?

The WFSX100C060B's cooling range reaches 2,145 CFM at rated static pressure, which covers typical 5 ton airflow. At airflow above 1,800 CFM, use bottom, two-side, or bottom-and-side returns.

Customer Review