decor decor

Summary

Product #179764: $4,330.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Thermostats:
  • Square to Round Adapters:
  • Return Flex Reducer or Increaser :
  • Supply Flex Reducer or Increaser :
4330
$4,330.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
WPA542A000RKB | 3.5-Ton Cooling Built for Big Floor Plans and 20 kW Heat Strip Flexibility

3.5 Ton EcoTemp 13.4 SEER2 R454B DOWN-FLOW or HORIZONTAL Package Unit WPA542A000RKB

· SKU 179764 · AHRI 215564972 · Package AC
SEER2
13.4
Capacity
42,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,788.00

Sale price:

$4,330.00
You save $1,458.00!

Click For Sale Price

Sale price:

$4,330.00

List price:

$5,788.00
You save: ($1,458.00)
  • SKU: 179764
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    13.4
  • Product Type:
    Package AC
  • Tonnage:
    3.5
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-454B
  • Airflow Direction:
    Downflow/Horizontal
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for EcoTemp Grandaire package units WPA5 WPH5 WGS0502
  • 7.5 KW heat strip for EcoTemp Grandaire package units WPA5 WPH5 WGS0752
  • 10 KW Breakered heat strip for EcoTemp Grandaire package units WPA5 WPH5 WGS1002H
  • 15 KW Breakered heat strip for EcoTemp Grandaire package units WPA5 WPH5 WGS1502H
  • 20 KW Breakered heat strip for EcoTemp Grandaire package units WPA5 WPH5 WGS2002H
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • EcoTemp Square to Round Adapter for WPA5 and WPH5 Package Units NPDUCFLG002A00
Return Flex Reducer or Increaser
  • 14" to 10" Metal Reducer
  • 14" to 12" Metal Reducer
  • 16" to 14" Metal Reducer
  • 18" to 14" Metal Reducer
Supply Flex Reducer or Increaser
  • 14" to 10" Metal Reducer
  • 14" to 12" Metal Reducer
  • 16" to 14" Metal Reducer
  • 18" to 14" Metal Reducer
Adding to cart… The item has been added

3.5 Ton EcoTemp 13.4 SEER2 R-454B Straight Cool Package Unit WPA542A000RKB

The EcoTemp WPA542A000RKB is the 3.5 ton WPA5, built for larger homes and busy small businesses that need more than 3 tons of cooling. It delivers 40,000 BTUh of rated cooling, with a 3/4 HP ECM blower moving 1,350 CFM at 13.4 SEER2. It is also the first WPA5 size that accepts a 20 kW electric heater, which adds flexibility for buildings that need occasional heat without a gas line. Everything ships factory charged with R-454B in a corrosion-resistant cabinet. Compare sizes in our 3.5 ton straight cool package unit category.

Is a 3.5 Ton Straight Cool Package Unit the Right Size?

A 3.5 ton package AC fits cooling loads of about 40,000 to 42,000 BTUh. That is common for larger ranch homes, two-story homes on a single system, and commercial spaces with equipment and customer traffic. Compared with the 3 ton, it adds 5,600 BTUh of rated cooling and steps up to a 3/4 HP blower with 1,350 CFM. That helps on long duct runs and in rooms far from the unit.

Heater sizing depends on how much winter heat you need. Options run from 5 kW up to 20 kW on this size, and any heater requires at least 1,400 CFM of airflow. For frequent or heavy heating, consider a gas or heat pump package unit, which typically costs less to run than straight electric resistance heat.

Ideal for: Larger single-story homes, two-story homes on one system, restaurants, retail stores, and fitness studios with 3.5 ton cooling loads.

Need more capacity? Step up to the 4 Ton EcoTemp Straight Cool Package Unit WPA548A000RKB for another half ton and a 1 HP blower.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, ductwork, climate, window area, occupancy, and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Package Unit WPA542A000RKB: 3.5 Ton Single-Packaged Air Conditioner (Straight Cool)
Cooling Capacity 40,000 BTUh Rated (42,000 BTUh Nominal), 1,350 CFM
Efficiency 13.4 SEER2 / 11.05 EER2
Refrigerant R-454B, Factory Charged, with Leak Detection Dissipation System
Compressor Scroll Compressor
Optional Electric Heat 5, 7.2, 10, 15, or 20 kW Heater (Sold Separately)
Airflow Configuration Convertible Downflow or Horizontal, Insulated Horizontal Duct Covers Included
Electrical 208/230V, Single Phase, 60 Hz; 25.4 MCA, 40 Amp Max Fuse/Breaker (Without Heater)

The WPA542A000RKB ships at about 398 lb and uses its own size-specific accessories: the CPECOMZR008A00 vertical economizer, the CPMANDPR008A00 manual outside air damper, and the CPFILTRK008A00 filter rack. Heater choices on our site include the 10 kW, 15 kW, and 20 kW breakered heat strips. Horizontal installs can use the NPDUCFLG002A00 square to round transition set.

Cooling System & Cabinet Features

WPA542A000RKB Cooling System

  • 40,000 BTUh rated cooling for 3.5 ton applications
  • 3/4 HP ECM blower rated for 1,350 CFM
  • 13.4 SEER2 and 11.05 EER2 efficiency
  • Scroll compressor rated 14.8 RLA / 109 LRA
  • 3-row indoor coil for strong moisture removal
  • Orifice metering with liquid filter drier
  • R-454B refrigerant with factory leak dissipation
  • PTC compressor start assist kit NPHSTART002A00 available
  • Optional low ambient control for cooling to 0°F
  • 74 dBA rated sound level

WPA542A000RKB Cabinet & Installation

  • First WPA5 size rated for a 20 kW electric heater
  • 1,400 CFM minimum airflow for electric heat
  • Size-specific economizer, outside air damper, and filter rack
  • Field-convertible downflow or horizontal ducting
  • Rust-free composite base and metal rails
  • CPRFCURB013B00 roof curb, or CPRFCURB011B00 with overhang
  • Crankcase heater CPCRKHTR004A00 available for sizes 42–60
  • Outdoor coil louver panels CPLOUVER009A00
  • Insulated evaporator compartment
  • 3-panel service access

Specifications & Manuals

Product documentation includes WPA5 technical specifications with performance, electrical, electric heater, and accessory data, the product brochure, and EcoTemp warranty terms to assist with equipment selection, installation, and service.

Frequently Asked Questions

What does the 3.5 ton WPA542A000RKB add over the 3 ton?

Rated cooling rises from 34,400 to 40,000 BTUh, the blower steps up from 1/2 to 3/4 HP, and airflow increases to 1,350 CFM. The 3.5 ton also accepts heaters up to 20 kW. Electrical is 25.4 MCA with a 40 amp maximum breaker without a heater.

What electrical service is needed with a 20 kW heater on the 3.5 ton WPA5?

With a 20 kW heater, the manufacturer lists an MCA of 97.5/111.4 amps at 208/230V and maximum overcurrent protection of 100/125 amps.

Which accessories are specific to the 3.5 ton WPA5?

Size 42 uses its own accessories: the CPECOMZR008A00 vertical and CPECOMZR011A00 horizontal economizers, the CPMANDPR008A00 manual outside air damper, and the CPFILTRK008A00 internal filter rack.

Should I add a start assist kit to the WPA542A000RKB?

The compressor's locked rotor rating is 109 amps. In locations with low voltage or long wire runs, the manufacturer's NPHSTART002A00 PTC start assist kit (single phase only) can help the compressor start more easily.

How much airflow does a heater require on the 3.5 ton?

The manufacturer requires at least 1,400 CFM for safe electric heater operation on size 42. That is slightly above the 1,350 CFM nominal cooling airflow, so set the blower speed for heat accordingly.

Is the WPA542A000RKB noticeably louder than the 3 ton?

No. The 3.5 ton is rated at 74 dBA, slightly below the 3 ton's 75 dBA rating.

Customer Review

You Might Also Like