decor decor

Summary

Product #179819: $2,930.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 46041 / 2 Ton Rheem Select R454B Single Stage Small Footprint Condenser WSA14AY24AJ1NA (F) (179816) -- 1
  • 41938 / 2 Ton Rheem Two Stage R454B Air Handler RH2TY2417STANNJ (179306) -- 1
2930
$2,930.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
WSA14AY24AJ1NA, RH2TY2417STANNJ | 2 Tons of ENERGY STAR Cooling in the Same Compact Cabinet as the 1.5 Ton

2 Ton Rheem Select 15.2 SEER2 R454B Small Footprint Central AC System WSA14AY24AJ1NA RH2TY2417STANNJ (F)

· SKU 179819 · AHRI 217133168 · Split System
SEER2
15.2
Capacity
24,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $4,106.00

Sale price:

$2,930.00
You save $1,176.00!
  • SKU: 179819
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • SEER2:
    15.2
  • Product Type:
    Split System
  • Tonnage:
    2
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    17.5"
  • AHRI Certificate:
  • AHRI Number:
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for Rheem Endeavor RH1PZ, RH2TZ, RXBH-1724B05J-1, WRX0502I
  • 7.2 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B07J-1, WRX0752I
  • 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T4 Pro Thermostat Programmable 1H/1C TH4110U2005
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 2 Ton Rheem Select 14.3 SEER2 R454B Single Stage Compact Condenser WSA14AY24AJ1NA
  • 2 Ton Rheem Two Stage R454B Air Handler RH2TY2417STANNJ
Adding to cart… The item has been added

2 Ton Rheem Select 15.2 SEER2 R454B Small Footprint Central AC System WSA14AY24AJ1NA, RH2TY2417STANNJ

This 2 ton Rheem Endeavor® Line Select™ Series iC system fits 24,000 BTU/h of cooling into the same compact 23.63" x 23.63" cabinet as the 1.5 ton. The WSA14AY24AJ1NA condenser is matched with the RH2TY2417STANNJ two-stage-airflow air handler and AHRI certified at 15.2 SEER2 (#217133168). Rheem lists the WSA14AY as ENERGY STAR® certified. It uses low-GWP R-454B with Rheem's PlusOne® Refrigerant Detection System™ in the air handler. It's cooling only, with optional Rheem electric heat strips.

Is a 2 Ton Air Conditioning System the Right Size?

Two tons (24,000 BTU/h) fits moderate cooling loads. That's often 2-bedroom homes, larger condos, townhomes and starter homes around 900–1,200 sq. ft. as a general reference. Similar floor plans can still need different tonnage.

Ceiling height, window orientation, insulation and duct condition all shape the load. Replacing like-for-like without a check can repeat an old sizing mistake. A Manual J load calculation confirms whether 2 tons is correct.

Ideal for: Townhomes, starter homes, rentals and 2-bedroom houses with limited room beside the house.

Need more capacity? Step up to the 2.5 Ton Rheem Select 15.2 SEER2 R454B Small Footprint Central AC System WSA14AY30AJ1NA, RH2TY3617STANNJ for a larger load.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit WSA14AY24AJ1NA — 2 Ton Rheem Select Small Footprint R454B Air Conditioner
Indoor Air Handler RH2TY2417STANNJ Two-Stage Airflow Multipoise Air Handler (17.5" Wide)
Application Cooling-Only Central Air Split System (Electric Heat Kit Optional)
Refrigerant R-454B (Low-GWP A2L Refrigerant)
Compressor Single-Stage Scroll Compressor
Metering Device Factory-Installed Expansion Valve on Indoor Coil (TXV)
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit — 14 MCA / 20A Max Overcurrent
Air Handler Electrical 208/240V, Single Phase — 3 MCA / 15A Max Overcurrent (No Heat Kit)

The WSA14AY24AJ1NA condenser is 32.25" tall on a 23.63" x 23.63" base and weighs 161 lbs (operating). It uses an 18" three-blade fan with a 1/7 HP motor and has a 76 dBA sound rating. The RH2TY2417STANNJ air handler is 17.5" wide and 42.5" tall and converts for upflow, downflow or horizontal installs. If pad space isn't a concern, compare the standard 2 ton Rheem Select WA14AY24BJ1NA system.

Condensing Unit & Air Handler Features

WSA14AY24AJ1NA Outdoor Condensing Unit

  • 24,000 BTU/h nominal cooling capacity
  • Single-stage scroll compressor
  • 76 dBA weighted sound power rating
  • Optimized 2-row 7 mm coil uses up to 15% less refrigerant
  • 101 oz. factory R-454B charge for 15 ft. of line set
  • 18" three-blade fan with 1/7 HP motor (2,036 CFM)
  • 3/8" liquid and 3/4" suction front-seating service valves
  • External gauge ports, rust-resistant screws and field-installed filter drier
  • One-piece drawn and painted base pan lifts the coil off the pad
  • 10-year conditional parts limited warranty (registration required)

RH2TY2417STANNJ Two-Stage Air Handler

  • Two-stage airflow with a constant torque (ECM) motor
  • 1/3 HP, 5-speed motor with 10" x 8" blower
  • PlusOne® Refrigerant Detection System™ with integrated A2L sensor
  • Aluminum fins bonded to internally grooved aluminum tubing
  • 4-way convertible: upflow, downflow, horizontal left or right
  • 1.0" foil-faced cabinet insulation for quieter operation
  • Cabinet air leakage under 2% at 1" H₂O (ASHRAE 193)
  • Works with any standard 24V thermostat
  • Expansion valve on indoor coil for AC or heat pump use
  • Field-installed 5, 8 and 10 kW heater kits with UL/cUL-listed breakers

Specifications & Manuals

Documentation includes WSA14AY electrical, sound, dimensional and line-size data, condenser and air handler installation instructions, submittals, the Rheem Select brochure, RH2TY airflow and heater tables and the Rheem limited warranty.

Frequently Asked Questions

Is the WSA14AY24AJ1NA ENERGY STAR certified?

Rheem's WSA14AY brochure lists the series as ENERGY STAR® certified. Certification depends on the matched indoor coil or air handler, so confirm the specific match on the ENERGY STAR or AHRI directory.

Do the 1.5 and 2 ton WSA14AY condensers use the same cabinet?

Yes. Both measure 32.25" x 23.63" x 23.63" and use the same 18" fan. The 2 ton has a larger compressor (10 RLA vs. 8 RLA) and needs a 14 MCA / 20A circuit instead of 12 MCA / 15A.

How does the WSA14AY base pan help with corrosion and noise?

Rheem uses a one-piece drawn and painted base pan that raises the coil off the pad. That keeps the coil away from standing water and debris and helps reduce operating sound.

How does this compare to the standard-footprint 2 ton Rheem Select system?

The WA14AY24BJ1NA, RH2TY2417STANNJ system is also rated 15.2 SEER2 but uses a wider, shorter 33.66" x 33.66" cabinet. The WSA14AY24 fits a much smaller pad.

What low ambient accessories fit the WSA14AY24AJ1NA?

Rheem lists the RXAD-A08 low ambient control. A 44-17402-44 compressor crankcase heater is recommended whenever the low ambient kit is installed.

Can I run a 5/8" suction line on the 2 ton WSA14AY24?

Yes. Rheem's line-size tables allow 5/8" or 3/4" suction lines on the 2 ton, with small capacity multipliers at longer lengths. Follow Rheem's installation instructions when connecting to the 3/4" suction service valve.