decor decor

Summary

Product #180116: $4,370.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 46571 / 2 Ton Goodman R32 Side Discharge Heat Pump Condenser GZV6SA2410 (180098) -- 1
  • 46584 / 2 Ton Goodman R32 Variable Speed Communicating Air Handler AHVE24BP1300 (180109) -- 1
4370
$4,370.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GZV6SA2410, AHVE24BP1300 | Variable-Speed 2-Ton Comfort for Tight Side Yards

2 Ton Goodman 18 SEER2 R32 Side Discharge Inverter Heat Pump System GZV6SA2410, AHVE24BP1300

· SKU 180116 · AHRI 215429191 · Split System
SEER2
18
Capacity
24,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,690.00

Our price:

$4,938.00

Sale price:

$4,370.00
You save $1,320.00!

Click For Sale Price

Sale price:

$4,370.00

List price:

$5,690.00

Our price:

$4,938.00
You save: 12% ($1,320.00)
  • SKU: 180116
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    18
  • Product Type:
    Split System
  • Tonnage:
    2
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    17.5"
  • Manufacturer Warranty:
    10 Years
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • Goodman GTST Connected Thermostat GTST-CW-WH-A
  • Daikin One Touch Smart Thermostat DTST-TOU-A
  • 1.5 Ton Goodman 16.2 SEER2 R32 Side Discharge Heat Pump Condenser GZV6SA2410
  • 2 Ton Goodman R32 Variable Speed Communicating Air Handler AHVE24BP1300
Adding to cart… The item has been added

2 Ton Goodman 18 SEER2 R-32 Side Discharge Inverter Heat Pump System

Pairing the Goodman GZV6SA2410 side discharge inverter heat pump with the AHVE24BP1300 communicating air handler, this 2 ton (24,000 BTU) R-32 system earns an AHRI-certified 18 SEER2 (AHRI #215429191). It brings variable-speed comfort to one- and two-bedroom homes, condos, and townhomes with a low-profile outdoor unit that tucks against a wall or mounts on a bracket instead of taking up a large pad. Homeowners replacing an older single-stage heat pump and contractors working on tight lots get quieter operation, precise humidity control, and Goodman's 10-year unit replacement limited warranty with registration.

Is a 2 Ton Inverter Heat Pump the Right Size?

Two tons commonly fits homes of about 900 to 1,200 square feet. Because this is a heat pump, the right size balances the cooling load against the heating load at your local winter design temperature, so a load calculation for both seasons is the most reliable guide.

Inverter systems are more forgiving than single-stage units because the compressor slows down on mild days, but oversizing still reduces dehumidification and efficiency. Consider window orientation, insulation, duct condition, and how cold your winters get. Goodman lists 14,200 BTU/h of heating at 5°F for this size, which is plenty for mild-winter regions, while colder areas typically add an electric heat kit.

Ideal for: One- and two-bedroom homes, condos and townhomes, smaller ranch homes, finished basements or additions, and replacements where the outdoor unit must fit a narrow side yard or wall bracket.

Need more capacity? Step up to the 2.5 Ton Goodman GZV6SA3010 & AHVE36CP1300 Inverter Heat Pump System for larger homes requiring additional heating and cooling capacity.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, windows, sun exposure, ceiling height, climate, occupancy, and ductwork. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit GZV6SA2410 — 2 Ton Side Discharge Inverter Heat Pump
Indoor Air Handler AHVE24BP1300 Communicating Variable-Speed Multi-Position Air Handler with EEV
Application Split System Heat Pump, Cooling & Heating — 18 SEER2, AHRI #215429191
Refrigerant R-32
Compressor Inverter-Driven Variable-Speed Swing Compressor
Blower Motor 1/2 HP Variable-Speed ECM, Constant CFM
Electrical 208-230V, Single Phase, 60 Hz Condensing Unit
Air Handler Electrical 208/230V, Single Phase, 60 Hz

The GZV6SA2410 heat pump shares the compact 36-5/8" x 13-3/4" x 27-3/8" cabinet of the 1.5 ton model and ships with 74 oz of R-32. Indoors, the AHVE24BP1300 is rated at 800 SCFM with this outdoor unit. Both connect with 3/4" suction and 3/8" liquid lines, so a 25 ft 3/4" x 3/8" copper line set handles most installs. For full smart-home control, upgrade to the Daikin One Touch smart thermostat, and add the 8 kW HKTSN08X1 heat strip where backup heat is needed.

Condensing Unit & Air Handler Features

GZV6SA2410 Outdoor Heat Pump

  • 2 ton variable-speed inverter heat pump on R-32
  • 23,200 BTU/h maximum cooling and heating at AHRI conditions
  • 64 dBA cooling sound rating; quiet mode as low as 58 dBA
  • Communicating controls with seven-segment LED diagnostics
  • Suction pressure transducer plus coil and ambient sensors
  • Field-installed bi-flow filter drier
  • 16.8 MCA with 20 amp maximum HACR breaker or time-delay fuse
  • Front-sealing 3/4" and 3/8" sweat service valves
  • Heavy-gauge galvanized cabinet with Ivory white powder paint
  • 10-year unit replacement and 10-year parts limited warranty with registration

AHVE24BP1300 Communicating Air Handler

  • 800 SCFM rated airflow with the GZV6SA2410
  • Constant CFM independent of duct static pressure (up to 0.9" w.c.)
  • Adjustable low-CFM fan-only setting from the thermostat
  • EEV metering optimized for R-32
  • Horizontal or vertical installation
  • 21" depth for easier attic access
  • Coil mounting track for quick repositioning
  • Rigid SmartFrame cabinet with glue-less insulation retention
  • Secondary drain connection on the thermoplastic drain pan
  • Accepts 5, 8, or 10 kW electric heat kits

Specifications & Manuals

Product documentation includes GZV6S heat pump specifications, installation instructions, service and parts manuals, AHVE air handler specifications and installation instructions, and Goodman warranty certificates to assist with equipment selection, installation, and service.

Frequently Asked Questions

How many square feet does the 2 ton GZV6SA2410 system typically handle?

As a general guideline, about 900 to 1,200 square feet. Insulation, windows, and winter temperatures all change the real requirement, so a load calculation is recommended.

How does the 2 ton system compare with the 1.5 ton GZV6SA1810 package?

Both use the same AHVE24BP1300 air handler and the same compact outdoor cabinet. The GZV6SA2410 adds capacity (23,200 vs. 17,100 BTU/h maximum cooling), the air handler runs at 800 instead of 610 SCFM, and the outdoor circuit moves to a 20 amp breaker. Efficiency is rated 18 SEER2 versus 19 SEER2 for the 1.5 ton.

Why does this Goodman system use R-32 refrigerant?

R-32 is a lower-GWP refrigerant used in many new heat pumps. It is an A2L refrigerant, so the AHVE24BP1300 includes a factory-installed R-32 sensor and is UL 60335-2-40 compliant. Read more in our refrigerant transition guide.

Is the GZV6SA2410 built for coastal or hurricane-prone areas?

It has a ZAM high-corrosion steel bottom frame and legs, is 500-hour salt-spray tested, and when properly anchored meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds. Anchor bracket kits are available.

Can I use quiet mode on the 2 ton GZV6SA2410?

Yes. Quiet mode offers three sound suppression levels; at level 3 the 2 ton unit drops to about 58 dBA sound power, with a capacity reduction listed at roughly 45%. Boost mode can raise compressor speed during unusually high loads.

Who should choose the 2 ton side discharge inverter system?

Homeowners in condos, townhomes, and smaller houses who want quiet, efficient heating and cooling, and contractors who need a compact outdoor unit for tight spaces or wall-bracket mounting.

 

 

Customer Review