decor decor

Summary

Product #179535: $5,675.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 45325 / 2 Ton Goodman R32 Two Stage Heat Pump Condenser GLZT7CA2410 (179522) -- 1
  • 45379 / 2.5 Ton Goodman R32 Variable Speed Air Handler AMVT30BP1300 (179527) -- 1
5675
$5,675.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GLZT7CA2410, AMVT30BP1300 | Compact two-stage R-32 comfort sized for condos, additions and smaller homes

2 Ton Goodman 17.5 SEER2 R32 Two Stage Heat Pump System GLZT7CA2410, AMVT30BP1300

· SKU 179535 · AHRI 215657363 · Split System
SEER2
17.5
Capacity
24,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $7,231.00

Our price:

$6,353.00

Sale price:

$5,675.00
You save $1,556.00!

Click For Sale Price

Sale price:

$5,675.00

List price:

$7,231.00

Our price:

$6,353.00
You save: 11% ($1,556.00)
  • SKU: 179535
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    17.5
  • Product Type:
    Split System
  • Tonnage:
    2
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    17.5"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • ProStat 7-Day Programmable Digital Thermostat 3H/2C PRS6320
  • Honeywell T6 Pro Thermostat 3H/2C Programmable TH6320U2008
  • 2 Ton Goodman 17.2 SEER2 R32 Two Stage Heat Pump Condenser, GLZT7CA2410
  • 2.5 Ton Goodman R32 Variable Speed Air Handler AMVT30BP1300
Adding to cart… The item has been added

2 Ton Goodman R-32 Two-Stage Heat Pump System – GLZT7CA2410 & AMVT30BP1300

The Goodman GLZT7CA2410 and AMVT30BP1300 pair a 24,000 BTU/h two-stage R-32 heat pump with a communicating variable-speed air handler, giving condos, townhomes, additions and smaller single-family homes year-round heating and cooling from one matched split system. Built for homeowners and contractors who want quiet, efficient comfort without paying for an oversized unit, this ComfortBridge-ready package is part of Goodman's GLZT7C series, rated up to 17.2 SEER2 and 8.2 HSPF2, and accepts 5 to 15 kW electric heat strips for backup heat on the coldest mornings.

Is a 2 Ton Heat Pump System the Right Size?

A 2 ton heat pump delivers a nominal 24,000 BTU/h of cooling and 24,000 BTU/h of heating, which suits homes and zones with a modest heat load. The right tonnage comes from the heat gain and heat loss of the space, not just its square footage. A tight, well-insulated home may need less capacity than a smaller home with large sun-facing windows. Our AC tonnage and BTU calculator is a helpful first step before a professional load calculation.

Insulation levels, window area and orientation, ceiling height, duct condition, occupancy and your local winter design temperature all affect whether 2 tons is enough. Because the GLZT7CA2410 uses a two-stage compressor, it can run at reduced capacity during mild weather and switch to full output when the load climbs. That makes it a good fit for smaller spaces where comfort swings are easy to notice.

Ideal for: Condos and townhomes, smaller single-family homes, home additions, bonus rooms and other single-zone ducted spaces needing about 24,000 BTU/h of heating and cooling.

Need more capacity? Step up to the 3 Ton Goodman GLZT7CA3610 & AMVT42CP1300 Heat Pump System for mid-size homes requiring additional heating and cooling capacity.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, duct design, window load, occupancy and desired indoor temperature. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump GLZT7CA2410 — 2 Ton Two-Stage R-32 Heat Pump Condenser
Indoor Air Handler AMVT30BP1300 Multi-Position Variable-Speed Air Handler (17.5" Cabinet)
Application Residential Ducted Split System Heat Pump — Heating & Cooling
Refrigerant R-32
Compressor Two-Stage Copeland UltraTech Scroll Compressor
Backup Heat Electric Heat Strip Selected at Checkout (5, 8, 10 or 15 kW)
Electrical 208/230V, Single Phase, 60 Hz Heat Pump
Air Handler Electrical 208/240V, Single Phase

Both halves of this system use the same 3/8" liquid and 3/4" suction connection sizes, so the 2 ton line set runs straight from the GLZT7CA2410 to the AMVT30BP1300 without suction adapters. The condenser ships charged for 15 feet of 3/8" liquid line. Inside, the AMVT30BP1300 has a factory-installed TXV and R-32 refrigerant sensor. In communicating mode it sets airflow for the 2 ton outdoor unit automatically: 536 CFM on low stage and 800 CFM on high stage, per Goodman airflow data. Prefer to buy separately? See the GLZT7CA2410 heat pump condenser and AMVT30BP1300 air handler.

Heat Pump & Air Handler Features

GLZT7CA2410 Outdoor Heat Pump

  • Two-stage Copeland UltraTech scroll compressor
  • Nominal 24,000 BTU/h cooling and 24,000 BTU/h heating capacity
  • 72 dB sound rating with grille-style sound control top
  • High-density foam compressor sound blanket
  • Integrated communicating ComfortBridge technology
  • Bluetooth commissioning and diagnostics with the CoolCloud app
  • 5mm copper tube / enhanced aluminum fin coil
  • Efficient two-speed ECM condenser fan motor
  • Factory-installed filter drier, suction accumulator, crankcase heater and muffler
  • Meets 2024 Florida Building Code hurricane-wind requirements when properly anchored

AMVT30BP1300 Variable-Speed Air Handler

  • 1/2 HP variable-speed ECM blower motor
  • Internal factory-installed thermal expansion valve
  • Factory-installed R-32 refrigerant sensor designed for the lifespan of the coil
  • Auto airflow and tonnage configuration in communicating mode
  • All-aluminum evaporator coil
  • 17.5" wide cabinet with 21" depth for easier attic access
  • Horizontal or vertical multi-position installation
  • Cabinet air leakage under 1.4% at 0.5" H2O (ASHRAE 193)
  • DecaBDE-free thermoplastic drain pan with secondary drain connections
  • Tool-less filter access and recall of the six most recent faults

Specifications & Manuals

Goodman documentation covers GLZT7C electrical data, expanded cooling and heating performance, dimensions and accessories, plus AMVT airflow tables and electric heat kit data for selecting the right heat strip.

Frequently Asked Questions

What kind of home is the 2 ton GLZT7CA2410 system best suited for?

It is a good match for condos, townhomes, additions and smaller single-family homes with a heating and cooling load of around 24,000 BTU/h. A Manual J load calculation is the best way to confirm 2 tons is the right fit.

Why is a 2 ton heat pump paired with a 2.5 ton AMVT30BP1300 air handler?

Goodman's airflow data rates the AMVT30BP1300 for 1.5 to 2.5 ton outdoor units. With the GLZT7CA2410, it runs at 536 CFM on low stage and 800 CFM on high stage, which suits a 2 ton heat pump.

Which heat strip size should I choose for this 2 ton system?

5, 8, 10 and 15 kW strips are available at checkout. Choose based on your winter heat loss and available electrical service. Larger kits raise the air handler's circuit requirements; a 5 kW kit, for example, calls for 26.5/29.9 MCA at 208/240V per Goodman heat kit data.

Do I need suction line adapters to install the GLZT7CA2410?

No. The condenser and the AMVT30BP1300 both use 3/8" liquid and 3/4" suction connections. Matching 3/4" x 3/8" copper line sets in 25' and 50' lengths are available as add-on options.

Can the AMVT30BP1300 air handler be installed in an attic?

Yes. It installs horizontally or vertically, has a 21" depth for easier attic access, and includes a thermoplastic drain pan with secondary drain connections.

What warranty comes with the 2 ton Goodman heat pump system?

Goodman offers a Lifetime Compressor Limited Warranty (for as long as you own your home) and a 10-Year Parts Limited Warranty when the system is registered online within 60 days of installation. Registration is not required in Florida, California or Québec. Other limitations apply; see Goodman's full warranty terms.

Customer Review

You Might Also Like