decor decor

Summary

Product #179537: $7,265.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 45327 / 4 Ton Goodman R32 Two Stage Heat Pump Condenser GLZT7CA4810 (179524) -- 1
  • 45382 / 5 Ton Goodman R32 Variable Speed Air Handler AMVT60DP1300 (179531) -- 1
7265
$7,265.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GLZT7CA4810, AMVT60DP1300 | 48,000 BTU two-stage heat pump power for growing families and larger floor plans

4 Ton Goodman 17.2 SEER2 R32 Two Stage Heat Pump System GLZT7CA4810, AMVT60DP1300

· SKU 179537 · AHRI 215657366 · Split System
SEER2
17.2
Capacity
48,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $9,168.00

Our price:

$8,497.00

Sale price:

$7,265.00
You save $1,903.00!

Click For Sale Price

Sale price:

$7,265.00

List price:

$9,168.00

Our price:

$8,497.00
You save: 14% ($1,903.00)
  • SKU: 179537
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    17.2
  • Product Type:
    Split System
  • Tonnage:
    4
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    24.5"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • 19kW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-19CB / HKTSD19CB  /WKS2002B
  • 25 KW breakered heat strip for Goodman ARUF, AVPTC, ARPT, ASPT, ASUF, AUPTC  HKSC-25DC / HKTSD25D1 HKTSD25DA
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 1 1/8 & 3/8
  • Copper Line Set 50' 1 1/8 & 3/8
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • ProStat 7-Day Programmable Digital Thermostat 3H/2C PRS6320
  • Honeywell T6 Pro Thermostat 3H/2C Programmable TH6320U2008
  • 4 Ton Goodman 17.2 SEER2 R32 Two Stage Heat Pump Condenser, GLZT7CA4810
  • 5 Ton Goodman R32 Variable Speed Air Handler AMVT60DP1300
Adding to cart… The item has been added

4 Ton Goodman R-32 Two-Stage Heat Pump System – GLZT7CA4810 & AMVT60DP1300

Larger homes and two-story floor plans need more airflow and more heating reserve, and this 4 ton Goodman system is built for that. The GLZT7CA4810 two-stage R-32 heat pump delivers a nominal 48,000 BTU/h. It is paired with the AMVT60DP1300, a 24.5-inch D-cabinet air handler with a 1 HP variable-speed blower that moves up to 1,600 CFM on high stage. With electric heat strip options up to 25 kW and communicating ComfortBridge controls, it suits growing families, larger ranch homes and contractors replacing aging 4 ton equipment.

Is a 4 Ton Heat Pump System the Right Size?

A 4 ton system handles roughly 48,000 BTU/h of heating and cooling load. Homes that land here often have more glass, higher ceilings, a second floor or a hot attic adding to the cooling load. Sizing up to 4 tons should be based on a measured load, not just a larger floor plan. Start with the AC tonnage calculator and confirm with a Manual J before ordering.

Duct capacity matters more at this size. On high stage the AMVT60DP1300 targets 1,600 CFM with a 4 ton outdoor unit, so undersized returns or long supply runs can limit performance. Also plan for winter: colder regions often need a larger heat strip, which affects the air handler's breaker and wire size.

Ideal for: Larger single-family homes, two-story houses, homes with high ceilings or large window areas, and replacement of existing 4 ton heat pump systems.

Need more capacity? Step up to the 5 Ton Goodman GLZT7CA6010 & AMVT60DP1300 Heat Pump System for the largest residential heating and cooling loads.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, duct design, window load, occupancy and desired indoor temperature. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump GLZT7CA4810 — 4 Ton Two-Stage R-32 Heat Pump Condenser
Indoor Air Handler AMVT60DP1300 Multi-Position Variable-Speed Air Handler (24.5" Cabinet)
Application Residential Ducted Split System Heat Pump — Heating & Cooling
Refrigerant R-32
Compressor Two-Stage Copeland UltraTech Scroll Compressor
Backup Heat Electric Heat Strip Selected at Checkout (5 to 25 kW)
Electrical 208/230V, Single Phase, 60 Hz Heat Pump
Air Handler Electrical 208/240V, Single Phase

The GLZT7CA4810 moves to a larger 7mm copper tube / enhanced aluminum fin coil and 1-1/8" suction valve. It holds a 229 oz factory R-32 charge, the largest in the GLZT7C series, sized for 15 feet of 3/8" liquid line. Goodman notes that installers supply 7/8" to 1-1/8" adapters for the suction connections. The AMVT60DP1300 runs 1,072 CFM on low stage and 1,600 CFM on high with this outdoor unit, and its 24.5" D cabinet accepts Goodman's largest heater kits. Both components are also listed separately: the GLZT7CA4810 heat pump and the AMVT60DP1300 air handler.

Heat Pump & Air Handler Features

GLZT7CA4810 Outdoor Heat Pump

  • Nominal 48,000 BTU/h cooling and heating capacity
  • Two-stage Copeland UltraTech scroll compressor
  • 7mm copper tube / enhanced aluminum fin coil
  • 1/3 HP two-speed ECM condenser fan motor
  • Simple low-voltage wiring to the outdoor unit in communicating mode
  • Color-coded terminal strip for non-communicating setup
  • High- and low-pressure switches for compressor protection
  • Steel louver coil guard and wire fan discharge grille
  • Single-panel control access with space for field-installed accessories
  • AHRI Certified; ETL Listed

AMVT60DP1300 Variable-Speed Air Handler

  • 1 HP variable-speed ECM blower with 11" blower wheel
  • Up to 1,600 CFM high-stage airflow with a 4 ton heat pump
  • 24.5" wide D cabinet
  • Accepts electric heater kits up to 25 kW
  • CFM indicator for airflow verification
  • Auto configuration of airflow and tonnage in communicating mode
  • Cabinet air leakage under 2.0% at 1.0" H2O (ASHRAE 193)
  • Glue-less cabinet insulation retention
  • UL 60335-2-40 compliant for R-32 refrigerant
  • Horizontal or vertical multi-position configuration

Specifications & Manuals

Use these Goodman sheets to verify 4 ton refrigerant line sizing, condenser electrical data, D-cabinet dimensions and the circuit requirements for each available heater kit.

Frequently Asked Questions

Is a 4 ton heat pump system a good fit for a two-story home?

Often, yes. Two-story and larger homes frequently land in the 48,000 BTU/h range. Still, confirm the load with a Manual J, since insulation and window exposure can shift the right size up or down.

Why does the 4 ton condenser come with a 5 ton air handler?

Goodman rates the AMVT60DP1300 for both 4 and 5 ton outdoor units. With the GLZT7CA4810, it runs 1,072 CFM on low stage and 1,600 CFM on high stage.

Do I need suction line adapters for the GLZT7CA4810?

Goodman's spec sheet notes that installers supply 7/8" to 1-1/8" adapters for suction connections. The condenser uses a 1-1/8" suction valve, and 25' and 50' 1-1/8" & 3/8" copper line sets are offered as options.

How much R-32 refrigerant is in the 4 ton heat pump?

The GLZT7CA4810 ships with 229 oz of R-32, charged for 15 feet of 3/8" liquid line. Adjust the final charge using the installation instructions' Final Charge Procedure.

How does a two-stage compressor benefit a larger home?

The two-stage Copeland UltraTech scroll runs at reduced capacity during milder conditions and moves to full capacity on peak days. Together with the variable-speed AMVT60DP1300, this gives steadier temperatures and better humidity control.

Can I use a conventional thermostat instead of a communicating one?

Yes. The GLZT7C series supports communicating ComfortBridge wiring and also has a color-coded terminal strip for non-communicating setup, so compatible 3H/2C heat pump thermostats can be used.

Customer Review

You Might Also Like