2 Ton Goodman 14.5 SEER2 R32 Heat Pump Wall Mount System GLZS4BA2410, AWST24SU13 Apartment/Condo Type
For two-bedroom apartments and mid-size condos, the Goodman 2 ton wall-mount heat pump system pairs the GLZS4BA2410 R-32 outdoor unit with the AWST24SU13 wall-hung air handler. It's an AHRI-certified match (AHRI #215218024) rated at 14.5 SEER2. The air handler keeps the same compact 20" small-chassis footprint as the 1.5 ton model but adds a 10 kW factory heat strip option for stronger backup heat. It's a practical upgrade for condo associations, landlords, and owners modernizing aging closet systems.
Is a 2 Ton Heat Pump System the Right Size?
Two tons is a common size for two-bedroom apartments and condos. Many older wall-hung systems in multi-family buildings were installed at this capacity, so this system is a good like-for-like replacement candidate.
Corner units, top-floor units, and units with large sliding doors or west-facing windows may carry higher loads than interior units of the same size. If you're unsure, a load calculation or our team can help confirm whether 2 tons is right.
Ideal for: Two-bedroom apartments and condos, townhouse-style multi-family units, and replacements of existing 2 ton wall-hung systems.
Need more capacity? Step up to the 2.5 Ton Goodman 15.2 SEER2 R32 Heat Pump Wall Mount System GLZS4BA3010, AWST30LU13 with the larger-chassis air handler.
Recommended sizing is a general guideline only. Actual system requirements depend on insulation, climate, ductwork, windows, occupancy, and home layout. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | GLZS4BA2410 — 2 Ton R-32 Heat Pump |
|---|---|
| Indoor Air Handler | AWST24SU13 Wall-Mount Air Handler (Small Chassis) |
| Application | Apartment/Condo Wall-Mount Split System Heat Pump |
| Refrigerant | R-32 |
| Compressor | Single-Stage Rotary Compressor |
| Efficiency | 14.5 SEER2 — AHRI #215218024 |
| Electrical | 208/230V, Single Phase, 60 Hz Outdoor Unit |
| Air Handler Electrical | 208/230V, Single Phase, 60 Hz (MCA/MOP varies by heat kit) |
The AWST24SU13's 1/3 HP multi-speed ECM blower and adjustable TXV are matched to the GLZS4BA2410 outdoor unit. The outdoor unit's 32-1/2" tall cabinet fits well on balconies, rooftops, and ground pads. Factory heat strips of 5, 8, or 10 kW, insulated line sets, and thermostats can be added at checkout. Prefer cooling only? See the 2 Ton Goodman R-32 wall mount air conditioner system.
Heat Pump & Air Handler Features
GLZS4BA2410 Outdoor Heat Pump
- 24,000 BTU/h nominal cooling and heating
- Single-stage rotary compressor (8.2 RLA)
- SmartShift quiet defrost
- Enhanced aluminum fin coil with 5 mm tubes
- 1/6 HP PSC condenser fan motor
- 11.2 A MCA, 15 A max overcurrent protection
- 3/8" liquid and 3/4" suction line sizes
- 29" W x 29" D x 32-1/2" H cabinet
- Steel louver coil guard
- Architectural Gray powder paint, 500-hour salt-spray approved
AWST24SU13 Wall-Mount Air Handler
- Compact 20-3/16" wide, 36" tall small chassis
- 1/3 HP multi-speed ECM blower, 10" x 6" wheel
- Fully adjustable thermal expansion valve
- Aluminum tubing coil
- Less than 2.0% cabinet leakage at 1.0 in. H2O
- Thermoplastic drain pan with primary and secondary drains
- Front or bottom return configuration
- Pull-type disconnect factory-installed
- Factory heat strip options: 5, 8, or 10 kW
- UL 60335-2-40 compliant, ETL listed
Specifications & Manuals
Product documentation includes outdoor heat pump and wall-mount air handler technical specifications, installation instructions, and Goodman warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
How does the 2 ton wall-mount system compare to the 1.5 ton?
Both use the same small-chassis AWST cabinet and 29" outdoor cabinet. The 2 ton adds 6,000 BTU/h of nominal capacity and offers a 10 kW factory heat strip option that the 1.5 ton doesn't.
How much airflow can the AWST24SU13 deliver?
Goodman's airflow table shows about 705 CFM on speed tap T3 and about 756 CFM on T5 at 0.5 in. w.c. external static pressure (230V, no filter).
Does the AWST24SU13 include an electrical disconnect?
Yes. Goodman factory-installs a pull-type disconnect in the AWST air handler, which simplifies service in tight closets.
What are the refrigerant connections on the 2 ton air handler and outdoor unit?
The GLZS4BA2410 uses a 3/8" liquid and 3/4" suction connection. Goodman lists the AWST24SU13 coil at 3/8" liquid and 5/8" suction. Your installer should follow both installation instructions for line sizing and any fittings needed.
Is there a cooling-only version of this 2 ton wall-mount system?
Yes. Budget Heating also carries the 2 ton Goodman R-32 wall-mount air conditioner system, which pairs the GLXS4BA2410 with the same AWST24SU13 air handler.
How do I qualify for Goodman's 10-year parts limited warranty?
Goodman requires online product registration within 60 days of installation (not required in California or Québec). See the warranty certificate for complete terms and exclusions.
"SEER2" stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).


AWST Technical Specifications