decor decor

Summary

Product #179830: $3,130.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 42016 / 3 Ton Goodman R32 Heat Pump Condenser GLZS4BA3610 (179392) -- 1
3130
$3,130.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GLZS4BA3610, AWST36LU13 | Top-of-the-Line Scroll Power for Penthouses & Large Condos

3 Ton Goodman 15.2 SEER2 R32 Heat Pump Wall Mount System GLZS4BA3610, AWST36LU13 Apartment/Condo Type

· SKU 179830 · AHRI 215217494 · Split System
SEER2
15.2
Capacity
36,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $4,780.00

Our price:

$4,360.00

Sale price:

$3,130.00
You save $1,650.00!

Click For Sale Price

Sale price:

$3,130.00

List price:

$4,780.00

Our price:

$4,360.00
You save: 28% ($1,650.00)
  • SKU: 179830
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    15.2
  • Product Type:
    Split System
  • Tonnage:
    3
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    24"
  • Manufacturer Warranty:
    10 Years
  • 3 Ton Goodman R32 Air Handler Wall Mount Apartment/Condo Type AWST36LU1305
  • 3 Ton Goodman R32 Air Handler Wall Mount Apartment/Condo Type AWST36LU1308
  • 3 Ton Goodman R32 Air Handler Wall Mount Apartment/Condo Type AWST36LU1310
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • 3 Ton Goodman 14.3 SEER2 R32 Heat Pump Condenser GLZS4BA3610
Adding to cart… The item has been added

3 Ton Goodman 15.2 SEER2 R32 Heat Pump Wall Mount System GLZS4BA3610, AWST36LU13 Apartment/Condo Type

The largest system in Goodman's R-32 wall-mount line, the 3 ton heat pump pairs the GLZS4BA3610 outdoor unit with the AWST36LU13 large-chassis air handler. It's a 15.2 SEER2, AHRI-certified match (AHRI #215217494). It's also the only size in this group with a scroll compressor and a wider 35-1/2" outdoor cabinet, and the air handler delivers the most airflow of any AWST model. It's built for big condos, penthouses, and multi-family units that need full 3 ton capacity in a wall-hung closet.

Is a 3 Ton Heat Pump System the Right Size?

Three tons is the top of the AWST wall-mount range. It's meant for larger condos and apartments with three or more bedrooms, open living areas, or significant glass and sun exposure.

Before choosing it, confirm the load with a calculation. Also check that the supply and return ductwork can carry about 1,100–1,230 CFM and that the closet fits the 24" W x 21" D large chassis. An oversized system in a small unit can short-cycle and struggle with humidity.

Ideal for: Three-bedroom condos, penthouses, large corner apartments, and multi-family units with high heating and cooling loads.

Need more capacity? The 3 ton AWST36LU13 is the largest wall-mount air handler in this Goodman line. For larger spaces, request a quote and our team will recommend another configuration.

Recommended sizing is a general guideline only. Actual system requirements depend on insulation, climate, ductwork, windows, occupancy, and home layout. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump GLZS4BA3610 — 3 Ton R-32 Heat Pump
Indoor Air Handler AWST36LU13 Wall-Mount Air Handler (Large Chassis)
Application Apartment/Condo Wall-Mount Split System Heat Pump
Refrigerant R-32
Compressor Single-Stage Scroll Compressor
Efficiency 15.2 SEER2 — AHRI #215217494
Electrical 208/230V, Single Phase, 60 Hz Outdoor Unit
Air Handler Electrical 208/230V, Single Phase, 60 Hz (MCA/MOP varies by heat kit)

The GLZS4BA3610 steps up to a scroll compressor and a 35-1/2" square cabinet, and it uses a 7/8" suction line. The AWST36LU13 large chassis has a 1/2 HP ECM blower with a 10" x 8" wheel, front return, and a built-in filter rack. Add a 5, 8, or 10 kW factory heat strip, a line set, or a thermostat at checkout. Prefer cooling only? See the 3 Ton Goodman R32 wall mount air conditioner system, or browse more Goodman equipment.

Heat Pump & Air Handler Features

GLZS4BA3610 Outdoor Heat Pump

  • 36,000 BTU/h nominal cooling and heating
  • Single-stage scroll compressor (16.4 RLA / 88 LRA)
  • SmartShift technology for quiet defrost
  • Wider 35-1/2" W x 35-1/2" D x 35-3/4" H cabinet
  • 3/8" liquid and 7/8" suction line sizes
  • 21.5 A MCA, 35 A max overcurrent protection
  • 83 oz factory R-32 charge
  • Accumulator, crankcase heater, and high/low pressure switches
  • Removable grille-style top compliant with UL 60335-2-40
  • 211 lb shipping weight

AWST36LU13 Wall-Mount Air Handler

  • Highest-airflow AWST: about 1,230 CFM at 0.5 in. w.c. on tap T5
  • 1/2 HP multi-speed ECM blower, 10" x 8" wheel
  • Large chassis: 36" H x 24" W x 21" D
  • Fully adjustable TXV
  • Aluminum tubing coil, 3/4" suction connection
  • Front return with built-in 18" x 20" x 1" filter rack
  • Factory-installed R-32 sensor
  • Bottom primary and secondary drain connections
  • Pull-type disconnect and wall-hanging bracket
  • Factory heat strips: 5, 8, or 10 kW

Specifications & Manuals

Product documentation includes outdoor heat pump and wall-mount air handler technical specifications, installation instructions, and Goodman warranty information to assist with equipment selection, installation, and service.

Frequently Asked Questions

What makes the 3 ton GLZS4BA3610 different from the smaller wall-mount systems?

It's the only size in this group with a scroll compressor (the 1.5–2.5 ton models use rotary compressors). It also has a wider 35-1/2" outdoor cabinet and a 7/8" suction line.

Is 3 tons the largest AWST wall-mount air handler Goodman makes?

Yes. The AWST series runs from 1.5 to 3 tons, so the AWST36LU13 is the top of the range.

What line set size does the 3 ton outdoor unit need?

Goodman specifies a 3/8" liquid line and 7/8" suction line for the GLZS4BA3610, while the AWST36LU13 coil connects at 3/8" and 3/4". Any suction adapter must be supplied in the field. Follow both installation instructions.

How much space does the GLZS4BA3610 outdoor unit need?

The unit measures 35-1/2" W x 35-1/2" D x 35-3/4" H, larger than the 29" cabinets on the smaller sizes. Allow the clearances listed in the installation manual.

Will this heat pump work in climates that drop below 0°F?

Goodman requires the OT18-60A outdoor thermostat with lockout where temperatures fall below 0°F with 50% or higher relative humidity. The factory heat strip provides backup heat.

Can the GLZS4BA3610 be anchored for hurricane-prone areas?

Yes. When properly anchored, Goodman states it meets 2023 Florida Building Code unit-integrity requirements for hurricane-type winds. The ABK-20 anchor bracket kit is available.

SEER2 Explained

"SEER2" stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).

Customer Review

You Might Also Like