decor decor

Summary

Product #180486: $4,135.00
  • Natural or Liquid Propane (LP) Gas:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 42061 / 2.5 Ton EcoTemp R454B Condenser W5A5S30AKAWA (179437) -- 1
  • 47025 / 2.5 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM30M17XA (180436) -- 1
  • 47146 / EcoTemp 95% Single Stage 60K BTU Gas Furnace, WFSX060B048B (180477) -- 1
4135
$4,135.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
W5A5S30AKAWA, W5AM30M17XA, WFSX060B048B | Mid-size 2.5 ton system with right-sized 60K condensing heat

2.5 Ton EcoTemp 15.2 SEER2 95% AFUE 60K BTU Single Stage Gas System W5A5S30AKAWA, W5AM30M17XA, WFSX060B048B

· SKU 180486 · AHRI 214966621 · Split System
SEER2
15.2
Capacity
30,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $5,375.00

Sale price:

$4,135.00
You save $1,240.00!
  • SKU: 180486
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    15.2
  • Product Type:
    Split System
  • Tonnage:
    2.5
  • Operating Mode:
    Gas
  • Refrigerant Type:
    R-454B
  • AFUE %:
    95
  • Airflow Direction:
    Multi-Position
  • Cabinet Width:
    17.5"
  • Manufacturer Warranty:
    10 Years
  • BTUs:
    60,000
  • EcoTemp (ICP) Natural Gas to Liquid Propane 90%+ LP Kit, AGAGC9NPS01E
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 2.5 Ton EcoTemp 14.3 SEER2 R454B Condenser W5A5S30AKAWA
  • 2.5 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM30M17XA
  • EcoTemp 95% Single Stage 60K BTU Gas Furnace, WFSX060B048B
Adding to cart… The item has been added

EcoTemp 2.5 Ton 15.2 SEER2 AC & 60K BTU High-Efficiency Gas Furnace – 17-1/2" Cabinet

At 2.5 tons (30,000 BTU), this EcoTemp gas system covers the middle of the residential range. The W5A5S30AKAWA R-454B condenser and W5AM30M17XA cased coil rate 15.2 SEER2 as an AHRI-matched set (AHRI 214966621). The WFSX060B048B condensing furnace delivers 58,000 BTU at up to 97.0% AFUE. All the indoor equipment fits a 17-1/2 in. width, so it works in the same closets, basements, and attics that hold most standard-width replacement furnaces. It suits many three-bedroom homes in the South and mid-Atlantic, where summer cooling needs are moderate to high and winters are cool but manageable.

Is a 2.5 Ton System with a 60K Furnace the Right Size?

A 2.5 ton air conditioner is commonly applied to homes of roughly 1,200 to 1,600 square feet, depending heavily on climate and construction. A 58,000 BTU heat output gives a reasonable balance for moderate winters without overshooting heat loss in a well-insulated home.

The 2.5 ton size is often where duct limits show up first. Older systems designed around 2 tons may restrict the roughly 1,000 CFM that 2.5 tons of cooling typically calls for. Have return and supply capacity checked along with the Manual J load. Window area, attic insulation, and duct location in unconditioned space can each move the result a half-ton either way.

Ideal for: Three-bedroom homes, split-level and ranch houses in mixed climates, and replacements where a 17-1/2 in. furnace and a 2.5 ton AC are already in place.

Need more capacity? For more winter heat at the same tonnage, see the EcoTemp 2.5 Ton 80K BTU Gas System (WFSX080B048B).

Recommended applications are general guidelines only. Actual system requirements depend on insulation, ductwork, climate, elevation, and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condenser W5A5S30AKAWA — 2.5 Ton Single-Stage R-454B Air Conditioner
Indoor Coil W5AM30M17XA — 2.5 Ton Multipoise Cased A-Coil, 17-1/2" Wide, Factory TXV
Gas Furnace WFSX060B048B — 60,000 BTU Input / 58,000 BTU Output Condensing Furnace
Furnace Cabinet Width 17-1/2" (35" tall)
Cooling Efficiency 15.2 SEER2 (AHRI 214966621)
Heating Efficiency 97.0% AFUE Upflow & Horizontal / 95% AFUE Downflow
Refrigerant R-454B
Compressor Single-Stage Scroll Compressor
Condenser Electrical 208/230V, Single Phase, 60 Hz — 16.5 MCA, 25A Max Fuse/Breaker
Furnace Electrical 115V, Single Phase, 60 Hz
Manufacturer Warranty 10-Year Parts with Timely Registration; 20-Year Furnace Heat Exchanger

The W5AM30M17XA is a true 2.5 ton coil with a 3/4 in. suction connection that matches the condenser's 3/4 in. vapor valve and rated vapor line. At 25-13/16 in. tall, it stays compact on top of the 35 in. WFSX060B048B 60K furnace, and both pieces are 17-1/2 in. wide. Compare other options in the 2.5 ton 92%+ AFUE gas furnace system category.

Condenser, Coil & Furnace Features

W5A5S30AKAWA Condenser & W5AM30M17XA Coil

  • 2.5 ton scroll compressor rated 12.7 RLA
  • 22.0 sq. ft. condenser coil face with six refrigerant circuits
  • 3,300 CFM direct-drive fan with vertical discharge
  • 71 dBA sound rating, the quietest W5A5S size, and 69 dBA with the sound shield
  • 5.5 lb factory R-454B charge for 15 ft of line set
  • 6°F subcooling charging target with the TXV indoor coil
  • W5AM30M17XA: 25-13/16 in. tall, 17-1/2 in. wide, about 61 lb operating weight
  • 3/4 in. suction connection with straight tube for brazeless fittings
  • Factory-installed A2L refrigerant sensor and harness
  • Split delta plate for fast coil access and cleaning

WFSX060B048B 60K BTU Condensing Furnace

  • Up to 97.0% AFUE (upflow/horizontal), 95.0% downflow
  • 58,000 BTU delivered heat with four burners
  • 17-1/2 in. wide, 35 in. tall cabinet
  • 3/4 HP multi-speed ECM blower covering 315–1,580 CFM cooling airflow
  • Factory-set cooling off-delay of 90 seconds, adjustable to 5 or 30 seconds
  • Heating blower on-delay factory set, off-delay adjustable
  • Insulated heat exchanger compartment
  • Field-convertible to propane with the accessory kit
  • Concentric vent kit available for a single wall penetration
  • Requires a field-supplied return-air filter for each return inlet

Specifications & Manuals

Documentation includes condenser, coil, and furnace product data, installation instructions, line-set and venting tables, wiring diagrams, and warranty terms for selection, installation, and service.

Frequently Asked Questions

What line set sizes fit the 2.5 ton W5A5S30AKAWA?

The rated line sizes are 3/4 in. vapor and 3/8 in. liquid, matching the condenser's 3/4 in. vapor service valve. See the vapor line sizing table in the W5A5S specifications for long or nonstandard runs.

How far apart can the condenser and furnace be installed?

The W5A5S supports up to 250 ft of total equivalent line length, with limits on vertical separation. Runs over 80 ft, or with more than 35 ft of vertical separation, count as long-line applications and require the accessories in the Long Line Guideline.

What subcooling should the installer charge the 2.5 ton system to?

The W5A5S specifications list a 6°F required subcooling for the 2.5 ton size with a TXV indoor coil. Final charge should follow the installation instructions.

How much refrigerant ships in the W5A5S30AKAWA?

It ships with 5.5 lb of R-454B, enough for a 15 ft line set with a 3/8 in. liquid line. Longer runs require a charge adjustment per the manufacturer's chart.

Does a condensing furnace need a condensate drain?

Yes. High-efficiency furnaces like the WFSX produce condensate that must be piped to an approved drain. The W5AM coil also needs its own drain. Follow the installation instructions and local code for trapping and any required neutralizer.

What cooling airflow can the WFSX060B048B deliver?

Its constant-torque ECM blower covers 315 to 1,580 CFM in cooling at rated static pressure, which handles the airflow a 2.5 ton system needs.

Customer Review