 |
 |
 |
 |
Rheem Select 1.5 Ton 14.3 SEER2 Central System WA14AY18AJ1N, RH2TY2417STANN
R-454B Refrigerant WA14AY Condenser Features and Benefits • Fully Louvered Steel Cabinet: Features durable construction to add protection from yard hazards, weather corrosion • Optimized 7mm Coil Design: Allows for improved airflow, heat transfer and energy consumption • Easily Accessible Control Box: Ease of installation and serviceability • Designing for Sustainability with Low GWP:
For 2025, the Environmental Protection Agency (EPA) has set a global
warming potential (GWP) limit of 700 for refrigerant used in heating and
cooling systems. This new requirement will result in a 78% lower GWP
than previous-generation refrigerants — with only minimal changes to
system installation. For us, this is another step toward our continued
sustainability goal of reducing greenhouse gas emissions, while still
delivering an exceptional level of energy efficient, dependable comfort • PlusOne Refrigerant Detection System: An
integrated one-box, patented design featuring the A2L sensor and
mitigation board, offering easier commissioning with a single component
and simplified wiring configuration, compatibility with any 24V
thermostat application and system protection by automatically pausing
outdoor unit operation — if excess refrigerant is detected RH2TY Air Handler Features and Benefits • Quiet Operation: Provided by a cabinet construction with 1.0 inch of foil faced insulation for quieter sound characteristics • Aluminum Indoor Coil Design: Constructed of aluminum fins bonded to internally grooved aluminum tubing and are more corrosion resistant • Versatile 4-Way Convertible Compact Design: Allow for upflow, downflow, horizontal left and horizontal right applications even in the smallest of spaces • Rugged Steel, Compact Cabinet Construction: Designed for added strength and versatility • Field Installed Auxiliary Heater Kits: Provide exact heat for indoor comfort and include circuit breakers which meet UL and cUL requirements for service disconnect • Less than 2% Cabinet Air Leakage at 1-inch H2O: When tested in accordance with ASHRAE Standard 193 • Designing for Sustainability with Low GWP:
For 2025, the Environmental Protection Agency (EPA) has set a global
warming potential (GWP) limit of 700 for refrigerant used in heating and
cooling systems. This new requirement will result in a 78% lower GWP
than previous-generation refrigerants — with only minimal changes to
system installation. For us, this is another step toward our continued
sustainability goal of reducing greenhouse gas emissions, while still
delivering an exceptional level of energy efficient, dependable comfort • PlusOne Refrigerant Detection System:
An integrated one-box, patented design featuring the A2L sensor and
mitigation board, offering easier commissioning with a single component
and simplified wiring configuration, compatibility with any 24V
thermostat application and system protection by automatically pausing
outdoor unit operation — if excess refrigerant is detected
|
|
 |
 |
 |
 |

|