WFER090C048C | Same Heat, Four Tons of Air

EcoTemp 80% Single Stage 90K BTU Gas Furnace WFER090C048C

· SKU 90072 · Furnace
Average Rating:
List price: $2,589.00

Sale price:

$1,450.00
You save $1,139.00!
  • SKU: 90072
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • Product Type:
    Furnace
  • Operating Mode:
    Gas
  • AFUE %:
    80
  • BTUs:
    90,000
  • Airflow Direction:
    Multi-Position
  • Cabinet Width:
    21"
Adding to cart… The item has been added

EcoTemp 80% Single Stage 90K BTU Gas Furnace, WFER090C048C

Same 88,000 BTUH of heat as the B-width 90K, but built around a 21 in. cabinet and a 4 ton blower — the WFER090C048C is the size to specify when the cooling load, not the heating load, is setting the airflow requirement. Output is 72,000 BTUH at 80.00% AFUE from four monoport burners, and the 1/2 HP five-speed motor with a 10 x 10 in. wheel delivers 1418 CFM heating and 1445 CFM cooling. The wider cabinet brings a 19-3/8 in. supply outlet and a 19-1/2 in. bottom inlet, which matters when the return trunk is already sized for a big system.

Is a 90K BTU Gas Furnace the Right Size?

The heating side of this furnace is identical in capacity to the 17-1/2 in. 90K model, serving larger homes and colder design temperatures at 72,000 BTUH delivered. What changes is the air side: a 4 ton cooling rating and roughly 200 CFM more airflow at the same static pressure than the B-width unit, plus a wider cabinet that reduces the transition work when mating to a 21 in. coil case.

That makes the choice between 090B042 and 090C048 primarily a cooling-side decision. If the outdoor unit is 4 tons, the C-width furnace is the correct blower match and the B-width unit will be short on airflow. If the outdoor unit is 3.5 tons and the plenum is 17-1/2 in., the B-width furnace saves both money and sheet metal. Certified temperature rise here is 35°F to 65°F, with external static of 0.15 heating and 0.50 cooling.

Ideal for: 4 ton system matches, larger homes where cooling airflow drives the selection, 21 in. plenums and coil cases, and Sun Belt properties with a moderate heating load but a substantial cooling load.

Need more capacity? Step up to the 110K BTU EcoTemp WFER110C060C Gas Furnace, which keeps the 21 in. cabinet and adds 22,000 BTUH plus a 5 ton blower.

Recommended applications are general guidelines only. Actual furnace selection depends on a calculated heat loss, duct design, venting, gas supply and local code. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Model Number WFER090C048C — 80% AFUE Single Stage Multipoise Gas Furnace
Heating Input 88,000 BTUH (Natural Gas)
Heating Output 72,000 BTUH
Efficiency 80.00% AFUE
Cabinet Width 21 in.
Cooling Size Up to 4 Ton / 48,000 BTUH
Airflow 1418 CFM Heating / 1445 CFM Cooling
Blower Motor 1/2 HP Direct Drive, 5 Speed, 10 x 10 in. Wheel
Burners 4 Monoport
Certified Temperature Rise 35°F – 65°F
Installation Positions Upflow, Downflow, Horizontal-Left, Horizontal-Right
Ignition Hot Surface Ignition
Electrical / Gas Connection 115V-60Hz-1Ph, 8.3 Max Amps / 1/2 in. NPT
Vent Connection 4 in.
Shipping Weight 137 lb
Warranty 1-Year Unit Replacement, 20-Year Heat Exchanger, 5-Year Parts (10-Year with Registration)

The 21 in. cabinet takes external bottom filter rack NAHB00701FF, which includes a 20 x 25 in. washable filter, and return air kit NAHA02101RA; the matching washable media six-pack is NAHA00706FB in 24 x 25. On the cooling side, pair with a 4 ton coil such as the EcoTemp W5AM48M21XA R-454B cased coil, whose 21 in. casing lines up with this furnace directly. Complete matched systems are on the condenser, furnace and cased coil page.

Furnace & Blower Features

WFER090C048C Heating & Controls

  • 88,000 BTUH input, 72,000 BTUH output, 80.00% AFUE
  • Four monoport burners with hot surface ignition
  • Certified temperature rise 35°F to 65°F
  • Electronic control center, LED diagnostics and self-test feature
  • WhiteRodgers redundant gas valve, size 43 factory orifice
  • 1/2 in. NPT gas connection, 4.5 to 13.6 in. W.C. natural gas inlet
  • Solid state time operation heating blower control
  • Certified for natural gas at 0 to 10,000 ft elevation
  • 20-year heat exchanger limited warranty
  • Standard NOx build, AHRI certified

WFER090C048C Cabinet & Airflow

  • 21 in. cabinet with a 19-3/8 in. supply outlet
  • 19-1/2 in. bottom inlet width for large return trunks
  • 1/2 HP five-speed blower with a wide 10 x 10 in. wheel
  • 1418 CFM heating and 1445 CFM cooling as shipped
  • Roughly 235 CFM more cooling airflow than the 17-1/2 in. 90K model
  • Certified external static pressure 0.15 heating / 0.50 cooling
  • Four-position installation without a conversion kit
  • 4 in. vent connection, Type B-1 vent compatible
  • 8.3 max amps, 11.0 ampacity, 6.8 motor FLA
  • 137 lb shipping weight

Specifications & Manuals

Compare the 090C048 and 090B042 rows in the physical data tables to see the airflow and blower differences at identical heating capacity. Dimensional data, the full air delivery chart and accessory part numbers for the 21 in. cabinet are all in the technical specifications.

Frequently Asked Questions

What is the difference between WFER090C048C and WFER090B042C?

Heating capacity is the same 88,000 BTUH input. The C model has a 21 in. cabinet and a 4 ton blower delivering 1445 CFM cooling; the B model has a 17-1/2 in. cabinet and a 3.5 ton blower at 1210 CFM. Choose by the cooling side.

What airflow does the 090C048 deliver?

1418 CFM in heating and 1445 CFM in cooling on the as-shipped speed taps with a filter installed. On the gray cooling tap the air delivery chart shows up to 1625 CFM at 0.1 in. w.c. external static.

What are the cabinet and supply outlet dimensions?

21 in. cabinet width, 19-3/8 in. supply outlet width, 19-1/2 in. bottom inlet width, and a 13-5/16 in. top and bottom flue collar.

Does a 21 in. furnace need a different filter rack?

Yes. Use NAHB00701FF, the 21 in. external bottom filter rack, which includes a 20 x 25 in. washable filter. The 14 in. and 17 in. racks used on the smaller cabinets will not fit.

What is the shipping weight of the WFER090C048C?

137 lb. That is 6 lb more than the 17-1/2 in. 90K furnace, largely accounted for by the wider cabinet and the larger 10 x 10 in. blower wheel.

Is a combustible floor base required?

Only for downflow installations on combustible flooring, and not at all when an evaporator coil case is used underneath. The part number is NAHA01101SB. Downflow on non-combustible floors needs no base.