5 Ton GrandAire R454B Variable Speed Air Handler, WCVL605CD
One indoor unit, two system sizes. The GrandAire WCVL605CD is the matched R-454B air handler for both the 4 ton W5H9V48AKAAA and the 5 ton W5H9V60AKAAA GrandAire inverter heat pumps. Its 750-watt constant-airflow ECM 2.0 blower moves 1,136 to 1,807 CFM at full 5 ton capacity, while an electronic expansion valve and all-aluminum coil keep refrigerant control precise across the system's wide modulation range. The 24.5-inch multi-position cabinet goes in an attic, closet, basement, or crawlspace and runs on 115V or 208/230V power. For larger homes in colder climates, pair it with the GrandAire 15kW breakered heat strip.
Is a 5 Ton Air Handler the Right Size?
The WCVL605CD serves the top of the GrandAire WCVL range, covering 4 and 5 ton heat pump systems in larger homes, two-story houses on one system, and open floor plans. Its blower is set up through the control board for the airflow each matched outdoor unit needs, so one model handles both tonnages.
Airflow is where large systems succeed or fail. At up to about 1,800 CFM, the supply trunk, branch runs, and especially the return path have to be sized to carry it. Also confirm the space fits the 24.49" W x 21.02" D x 52.99" H cabinet and that the platform or support can carry its 162.92 lb.
Ideal for: Larger homes and high-load replacements on a 4 or 5 ton GrandAire W5H9V inverter heat pump, especially where strong electric backup heat is needed.
Need less capacity? Consider the 3 Ton GrandAire R454B Variable Speed Air Handler, WCVL365CC for mid-size homes on a 3 ton system.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, duct design, window area, and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Indoor Air Handler | WCVL605CD — 4-5 Ton Variable Speed Multi-Position Air Handler |
|---|---|
| Matched Heat Pumps | W5H9V48AKAAA 4 Ton or W5H9V60AKAAA 5 Ton (sold separately) |
| Blower | Constant-Airflow ECM 2.0, 750 W, 1,136–1,807 CFM (5 ton match) |
| Metering Device | Electronic Expansion Valve (EEV) |
| Refrigerant | R-454B |
| Electrical | 115/208/230V, Single Phase, 60 Hz — MCA 14.5 (115V) / 11.0 (208/230V), MOP 15 |
| Electric Heat | Optional 10kW or 15kW GrandAire WEAH Heat Strip |
| Filter | Filter rack included |
| Dimensions / Weight | 24.49" W x 21.02" D x 52.99" H — 162.92 lb |
This listing is for the WCVL605CD indoor air handler. Your choice of 4 or 5 ton W5H9V outdoor heat pump and the optional heat strip are sold separately. Refrigerant connections are 3/8" liquid and 3/4" gas flare.
Air Handler & Matched Heat Pump Features
WCVL605CD Variable Speed Air Handler
- Matched indoor unit for both 4 and 5 ton W5H9V heat pumps
- 750 W constant-airflow ECM 2.0 blower
- Up to 1,807 CFM at 5 ton turbo speed
- Electronic expansion valve and all-aluminum coil
- 24.5" multi-position cabinet, upflow, downflow, or horizontal
- Approved for 10kW and 15kW GrandAire heat strips
- Optional 1" R4.2 fiberglass-free cabinet insulation
- 10-year parts warranty
W5H9V48AKAAA / W5H9V60AKAAA Matched Heat Pumps (sold separately)
- 4 ton: 16.5 SEER2, 10.5 EER2, and 9.5 HSPF2
- 5 ton: 16 SEER2, 10 EER2, and 9.0 HSPF2
- 46,000 BTU/h (4 ton) or 52,000 BTU/h (5 ton) of heating at 5°F
- Inverter compressors with wide capacity modulation
- Side discharge cabinets
- Heating down to -22°F outdoor ambient
- Line sets up to 246 ft
- 10-year parts warranty
Specifications & Manuals
Documentation includes the 4 ton and 5 ton matched system submittals, the WCVL605CD parts list, and WCVL installation and service manuals covering airflow setup, wiring, and heat strip compatibility.
Frequently Asked Questions
Can the WCVL605CD be used with both 4 and 5 ton heat pumps?
Yes. The WCVL605CD is the matched indoor unit for both the W5H9V48AKAAA 4 ton and the W5H9V60AKAAA 5 ton GrandAire inverter heat pumps, with airflow configured for the outdoor unit you install.
Why isn't a 5kW heat strip recommended for the WCVL605CD?
Grandaire's WCVL heater compatibility data doesn't approve 5kW for the largest cabinet. Use the 10kW WEAH10EAA or 15kW WEAH15EAA breakered heat strip instead.
What power supply does the WCVL605CD need without electric heat?
Without a heat strip, the blower and controls need a minimum circuit ampacity of 14.5A at 115V or 11.0A at 208/230V, with 15A maximum overcurrent protection. A heat strip requires 208/230V.
Is fiberglass-free insulation available for the WCVL605CD?
Yes. Grandaire offers an optional 1-inch R4.2 fiberglass-free insulation package for the WCVL cabinet.
How heavy is the WCVL605CD for attic or platform installs?
It weighs 162.92 lb net and measures 24.49" W x 21.02" D x 52.99" H. Make sure the platform, hangers, or attic framing can safely support it.
Does the WCVL605CD come with a filter rack?
Yes. A filter rack is included with the air handler. Check the installation instructions for the correct filter dimensions before ordering replacements.
W5H9V60AKAAA, WCVL605CD Submittal Sheet
GrandAire WCV1605CD Parts List
GrandAire WCVL Installation Instructions
GrandAire WCVL Service Manual