decor decor

Summary

Product #179848: $4,940.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Indoor Air Quality:
  • Thermostats:
  • 46073 / 5 Ton Goodman R32 Heat Pump Condenser GLZS5BA6010 (179837) -- 1
  • 42025 / 5 Ton Goodman R32 Air Handler AMST60DU1300 (179401) -- 1
4940
$4,940.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GLZS5BA6010, AMST60DU1300 | Flagship 16 SEER2 Power With a 1 HP ECM D-Cabinet Air Handler

5 Ton Goodman 16 SEER2 R32 Heat Pump System GLZS5BA6010, AMST60DU1300

· SKU 179848 · AHRI 218222713 · Split System
SEER2
16
Capacity
60,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $7,995.00

Our price:

$7,400.00

Sale price:

$4,940.00
You save $3,055.00!

Click For Sale Price

Sale price:

$4,940.00

List price:

$7,995.00

Our price:

$7,400.00
You save: 33% ($3,055.00)
  • SKU: 179848
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    16
  • Product Type:
    Split System
  • Tonnage:
    5
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    24.5"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • 19kW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-19CB / HKTSD19CB  /WKS2002B
  • 25 KW breakered heat strip for Goodman ARUF, AVPTC, ARPT, ASPT, ASUF, AUPTC  HKSC-25DC / HKTSD25D1 HKTSD25DA
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 1 1/8 & 3/8
  • Copper Line Set 50' 1 1/8 & 3/8
  • Clean Comfort 1" Electronic Cleaner 23x20 model AE10-2320-14
  • Clean Comfort Electronic Air Cleaner, AE14-2025-51
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • 5 Ton Goodman 15.2 SEER2 R32 Heat Pump Condenser GLZS5BA6010
  • 5 Ton Goodman R32 Air Handler AMST60DU1300
Adding to cart… The item has been added

5 Ton Goodman 16 SEER2 R32 Heat Pump System GLZS5BA6010, AMST60DU1300

Goodman's largest GLZS5B R-32 heat pump system pairs the GLZS5BA6010 outdoor unit with the AMST60DU1300 air handler. The air handler is the line's only D-cabinet model, with a 1 HP ECM blower and 11" x 10" wheel. This AHRI-certified match (AHRI #218222713) is listed at 16 SEER2, the highest efficiency in this product line. It delivers about 57,000 BTU/h of cooling at 95°F and 57,000 BTU/h of heating at 47°F, with 1,810 CFM of rated airflow. It's built for large homes that need maximum single-system capacity, with backup heat options up to 25 kW.

Is a 5 Ton Heat Pump System the Right Size?

Five tons is the top of the residential split-system range, so this system should only be chosen when a load calculation confirms the need. Large square footage, extensive glass, high ceilings, and demanding climates are the usual drivers.

At this size, ductwork has to move about 1,810 CFM quietly, and the electrical service has to support the outdoor unit plus any heat strips. Very large or zoned homes may be better served by two smaller systems, which our team can help evaluate.

Ideal for: Large single-family and estate homes, homes with high ceilings or extensive glass, and residences with a confirmed load near 5 tons.

Need more capacity? The GLZS5BA6010 is the largest size in this line. For larger homes, request a quote for a multi-system or zoned design, or compare the 5 Ton Goodman R32 air conditioner system if you only need cooling.

Recommended sizing is a general guideline only. Actual system requirements depend on insulation, climate, ductwork, windows, occupancy, and home layout. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump GLZS5BA6010 — 5 Ton R-32 Heat Pump
Indoor Air Handler AMST60DU1300 Multi-Position ECM Air Handler (D Cabinet)
Application Residential Split System Heat Pump (Heating & Cooling)
Refrigerant R-32
Compressor High-Efficiency Scroll Compressor
Efficiency 16 SEER2 — AHRI #218222713
Electrical 208/230V, Single Phase, 60 Hz Outdoor Unit
Air Handler Electrical 208/240V, Single Phase, 60 Hz

The AMST60DU1300 is the only air handler in this series with a 24.5" D cabinet and a full 1 HP ECM motor. Goodman lists it with heater kits up to 25 kW, and a 25 kW breakered heat strip is offered with this system. The GLZS5BA6010 outdoor unit is the tallest in the line at 41-5/8" and holds 185 oz of factory charge. Line sets, D-cabinet filters, and thermostats are available as options. Browse more Goodman heat pumps and air handlers.

Heat Pump & Air Handler Features

GLZS5BA6010 Outdoor Heat Pump

  • About 57,000 BTU/h cooling at 95°F (rated match)
  • About 57,000 BTU/h heating at 47°F; 37,000 at 17°F
  • High-efficiency scroll compressor (27.1 RLA)
  • Enhanced aluminum fin coil with 7 mm copper tubes
  • 1/5 HP PSC condenser fan motor
  • 35-1/2" W x 35-1/2" D x 41-5/8" H cabinet
  • 34.8 A MCA, 60 A max overcurrent protection
  • 1-1/8" suction line, 7/8" suction valve
  • 185 oz factory R-32 charge
  • 74.8 dB rated sound level

AMST60DU1300 Air Handler

  • 1,810 CFM rated airflow, the highest in the line
  • 1 HP multi-speed ECM blower, 11" x 10" wheel
  • 24.5" wide D cabinet, 58" tall
  • Factory-installed TXV
  • All-aluminum evaporator coil, 7/8" suction connection
  • Factory R-32 refrigerant sensor
  • Horizontal or vertical configuration
  • 8.6 A MCA, 15 A max overcurrent (without heat strip)
  • Uses 23" x 20" D-cabinet filter
  • Heat strips from 5 kW up to 25 kW breakered

Specifications & Manuals

Product documentation includes outdoor heat pump and air handler technical specifications, installation instructions, and Goodman warranty information to assist with equipment selection, installation, and service.

Frequently Asked Questions

Should a very large home use one 5 ton GLZS5BA6010 or two smaller systems?

It depends on the load and layout. A single 5 ton system works when the calculated load is near 5 tons and the ductwork supports about 1,810 CFM. Zoned or multi-level homes may be better served by two systems.

What do you gain moving from the 4 ton to the 5 ton Goodman system?

Rated cooling rises from about 45,500 to 57,000 BTU/h at 95°F. Airflow increases to 1,810 CFM with a 1 HP ECM blower, and the system is listed at 16 SEER2 vs. 15.2.

Why does the AMST60DU1300 use a larger D cabinet?

The 24.5" wide D cabinet houses a larger coil and an 11" x 10" blower wheel with a 1 HP ECM motor to move the higher airflow a 5 ton system needs.

Can the 5 ton system use a 25 kW heat strip?

Yes. A 25 kW breakered heat strip (HKTSD25DA) is offered with this system, and Goodman's AMST heat kit data includes 25 kW kits for the AMST60DU1300. A 25 kW kit requires a substantial electrical supply, so have the circuits sized by a licensed electrician.

How much heat does the 5 ton system produce at 17°F?

Goodman's heating data shows about 37,000 BTU/h at 17°F outdoors for the GLZS5BA6010 + AMST60DU1300, the highest low-temperature output in this line.

How much does the GLZS5BA6010 outdoor unit weigh?

Goodman lists the 5 ton outdoor unit at 309 lb equipment weight and 329 lb shipping weight.

SEER2 Explained

"SEER2" stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).

Customer Review

You Might Also Like