decor decor

Summary

Product #179427: $3,530.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Indoor Air Quality:
  • Thermostats:
  • 39077 / 5 Ton Goodman R32 A/C Condenser GLXS4BA601 (179387) -- 1
  • 42025 / 5 Ton Goodman R32 Air Handler AMST60DU1300 (179401) -- 1
3530
$3,530.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GLXS4BA6010, AMST60DU1300 | Maximum-Capacity R-32 Cooling with ECM Fan Power

5 Ton Goodman 14 SEER2 R32 A/C System GLXS4BA6010, AMST60DU1300

· SKU 179427 · AHRI 214860141 · Split System
SEER2
14
Capacity
60,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $6,329.00

Our price:

$5,470.00

Sale price:

$3,530.00
You save $2,799.00!

Click For Sale Price

Sale price:

$3,530.00

List price:

$6,329.00

Our price:

$5,470.00
You save: 35% ($2,799.00)
  • SKU: 179427
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14
  • Product Type:
    Split System
  • Tonnage:
    5
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    24.5"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • 19kW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-19CB / HKTSD19CB  /WKS2002B
  • 25 KW breakered heat strip for Goodman ARUF, AVPTC, ARPT, ASPT, ASUF, AUPTC  HKSC-25DC / HKTSD25D1 HKTSD25DA
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 1 1/8 & 3/8
  • Copper Line Set 50' 1 1/8 & 3/8
  • Clean Comfort 1" Electronic Cleaner 23x20 model AE10-2320-14
  • Clean Comfort Electronic Air Cleaner, AE14-2025-51
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 5 Ton Goodman 14.3 SEER2 R32 A/C Condenser GLXS4BA6010
  • 5 Ton Goodman R32 Air Handler AMST60DU1300
Adding to cart… The item has been added

5 Ton Goodman 14 SEER2 R32 A/C System GLXS4BA6010, AMST60DU1300

The flagship capacity of the GLXS4B R-32 series pairs the 60,000 BTU/h GLXS4BA6010 condenser with the D-cabinet AMST60DU1300 air handler (AHRI #214860141, 14 SEER2). This is the maximum-capacity single-phase package in the lineup. It's built for owners of very large homes, and for single-phase light commercial spaces like small offices, studios and retail suites that need serious cooling from one split system. Unlike the smaller GLXS4B units, it's the only one with an ECM condenser fan motor. The air handler adds a 1 HP ECM blower and supports heat kits up to 25 kW.

Is a 5 Ton Air Conditioning System the Right Size?

At 60,000 BTU/h, 5 tons is the upper limit for most single-phase residential split systems. It's typically considered for large homes, often around 2,500–3,000 sq. ft. or more as a rough reference, or for light commercial spaces with high internal loads. Because it's the largest size, oversizing mistakes are costly: bigger ducts, higher electrical service and humidity problems if the load isn't really there.

Confirm the load with a Manual J (residential) or a commercial load calculation. Check that the duct system can carry 5 ton airflow, and verify the electrical panel has room for a 50A condenser circuit plus the air handler and any heat kit. Very large homes are sometimes better served by two smaller zoned systems, and our team can help you compare.

Ideal for: Large single-family homes, high-ceiling custom homes, single-phase small offices, studios and retail suites with high cooling demand.

Want higher efficiency? Compare the 5 Ton Goodman 16.2 SEER2 R32 A/C System GLXS5BA6010, AMST60DU1300, which uses the same air handler with a higher-efficiency GLXS5 condenser.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit GLXS4BA6010 — 5 Ton R32 Split System Air Conditioner
Indoor Air Handler AMST60DU1300 Multi-Position ECM Air Handler (D Cabinet, 24.5" Wide)
Application Cooling-Only Central Air Split System (Electric Heat Kit Optional)
Refrigerant R-32
Compressor Single-Stage Scroll Compressor with Advanced Copeland® Technology
Metering Device Factory-Installed Internal Thermal Expansion Valve (TXV)
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit — 32.4 MCA / 50A Max Overcurrent
Air Handler Electrical 208/240V, Single Phase — 8.6 MCA / 15A Max Overcurrent (No Heat Kit)

The GLXS4BA6010 is the tallest condenser in the series at 35-1/2" x 35-1/2" x 39-1/2" and 224 lbs, with a 1/3 HP ECM fan motor and a 94 oz. factory charge. Set it on a pad sized for its footprint. Hurricane-zone installs should use proper tie-downs from our condenser pads, wall mounts and tie-downs selection. The AMST60DU1300 steps up to the 24.5" D cabinet (58" tall, 24-5/8" deep) with an 11" x 10" blower wheel. Replacing just the outdoor unit? The 5 ton GLXS4BA6010 condenser is sold separately. The 5 ton Goodman R32 heat pump system GLZS4BA6010 is available if you want heat pump heating.

Condensing Unit & Air Handler Features

GLXS4BA6010 Outdoor Condensing Unit

  • 60,000 BTU/h nominal cooling, the largest in the GLXS4B series
  • Single-stage scroll compressor with Advanced Copeland® Technology
  • 1/3 HP ECM condenser fan motor, the only ECM fan in the series
  • 76 dBA rated sound level
  • 94 oz. factory R-32 charge for 15 ft. of tubing
  • 1-1/8" suction line recommended (7/8" service valve; adapter field supplied)
  • Factory-installed filter drier and high-pressure switch
  • Extended-life capacitors and enclosed contactor
  • Top and side maintenance access
  • 2023 Florida Building Code hurricane-wind compliant when properly anchored

AMST60DU1300 Multi-Position Air Handler

  • 60,000 BTU/h nominal capacity in a 24.5" D cabinet
  • 1 HP direct drive, multi-speed ECM blower with 11" x 10" wheel
  • Internal factory-installed TXV
  • All-aluminum evaporator coil optimized for R-32
  • Upflow or horizontal, with a DFKE-03 downflow kit available
  • Rigid SmartFrame™ cabinet with glue-less insulation retention
  • Foil-faced internal insulation and screw-less sides and back
  • Tool-less access to a 23" x 20" filter
  • Accepts HKTS electric heat kits from 3 kW up to 25 kW
  • AHRI certified, ETL listed and UL 60335-2-40 compliant

Specifications & Manuals

Documentation includes GLXS4BA6010 electrical, charge and line-size data, AMST60DU1300 D-cabinet dimensions, airflow tables, single-point wiring and heat kit data up to 25 kW.

Frequently Asked Questions

Is 5 tons the largest size in the GLXS4 lineup?

Yes. Goodman offers the GLXS4B series from 1-1/2 to 5 tons, and the GLXS4BA6010 is the top capacity at 60,000 BTU/h.

What sets the 5 ton GLXS4BA6010 apart from the 4 ton?

It adds 12,000 BTU/h of capacity, a taller 39-1/2" cabinet and a 1/3 HP ECM condenser fan in place of the 4 ton's PSC motor. It's paired with the larger D-cabinet AMST60DU1300 instead of the C-cabinet AMST48CU1300.

Why does the 5 ton use the D-cabinet AMST60DU1300?

Five tons of airflow calls for a bigger blower and coil. The 24.5" D cabinet houses an 11" x 10" blower wheel driven by a 1 HP ECM motor.

Can the AMST60DU1300 support 25 kW of electric heat?

Yes. Goodman's heat kit data lists the HKTSD25 (24 kW at 240V) for the AMST60DU1300, along with smaller single-phase kits and three-phase options.

Is the GLXS4BA6010 suitable for light commercial spaces?

It can serve single-phase light commercial spaces such as small offices or retail suites, as long as the load calculation supports 5 tons. Both components run on 208/230V single-phase power, not three-phase.

What footprint should I plan for with the GLXS4BA6010?

The condenser measures 35-1/2" x 35-1/2" and stands 39-1/2" tall. Choose a pad larger than that footprint and leave the service clearances listed in the installation manual.

SEER2 Explained

"SEER2" stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).

Customer Review

You Might Also Like