4 Ton Rheem 13.4 SEER2 R454B Heat Pump Package Unit RHPBYB048AJT000NAAUA
For larger homes in areas with real winters, the Rheem RHPBYB048AJT000NAAUA delivers 26,200 BTU/h of heating at 17°F at a 2.32 COP, the highest low-temperature efficiency among the 3 to 5 ton RHPBYB models. This 4 ton dedicated-horizontal packaged heat pump is rated 13.4 SEER2 and 6.7 HSPF2 under AHRI #215863992 on R-454B refrigerant and includes the factory tinned indoor coil option.
Is a 4 Ton Package Heat Pump the Right Size?
Rheem rates the RHPBYB048AJT000NAAUA at 46,000 BTU/h of net cooling and 45,500 BTU/h of heating at 47°F. That fits larger homes, houses with high ceilings or extensive glass, and homes with long heating or cooling seasons.
Duct capacity often decides how well a 4 ton package heat pump performs. Supply and return ducts must carry 1,600 CFM without excess noise or static pressure. Confirm the load with a calculation before choosing between 3.5, 4, and 5 tons, and size backup heat for your coldest design temperature.
Ideal for: Larger homes, homes with vaulted ceilings or lots of glass, colder-climate homes, and replacement of an existing 4 ton horizontal package heat pump.
Need more capacity? Step up to the 5 Ton Rheem 13.4 SEER2 R454B Heat Pump Package Unit RHPBYB060AJT000NAAUA, the largest model in the RHPBYB series.
Recommended system sizes are general guidelines only. Actual heating and cooling requirements depend on insulation, climate, windows, ductwork, ceiling height, and occupancy. A Manual J load calculation is the best way to confirm sizing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Unit Type | RHPBYB048AJT000NAAUA — 4 Ton Dedicated Horizontal Packaged Heat Pump |
|---|---|
| Cooling Capacity | 46,000 BTU/h AHRI Net Cooling, 1,600 CFM AHRI Rated Airflow |
| Heating Capacity | 45,500 BTU/h at 47°F / 26,200 BTU/h at 17°F |
| Efficiency | 13.4 SEER2 / 10.6 EER2 / 6.7 HSPF2 |
| Refrigerant | R-454B (A2L, Low GWP) |
| Indoor Coil | Factory Tinned Evaporator Coil (AUA Option) |
| Electrical | 208/230V, Single Phase, 60 Hz — MCA 37 A, Max Overcurrent 50 A (Without Heat) |
| Backup Heat | Optional Field-Installed Heat Strip, up to 20 kW |
The 4 ton shares the 37-1/8" cabinet, 4,100 CFM condenser fan, and coil layout of the 3.5 ton model but adds a larger compressor and 1,600 CFM of airflow. Plan for a 37 A minimum circuit ampacity and up to a 50 A breaker without heat, a solid equipment pad for the 397 lb unit, and up to a 20 kW heat strip.
Package Heat Pump Features
RHPBYB048AJT000NAAUA Heating, Cooling & Outdoor Section
- 26,200 BTU/h heating at 17°F, 2.32 COP
- Single-stage scroll compressor (22.4 RLA)
- Two-row outdoor coil, 13.65 sq. ft.
- Factory tinned three-row indoor coil
- 24" condenser fan, 4,100 CFM
- Demand defrost control
- PlusOne® Refrigerant Detection System
- 156.5 oz R-454B factory charge
- 37-1/8" cabinet height, 397 lbs net
- High and low pressure controls
Indoor Airflow, Installation & Service
- 1,600 CFM AHRI rated airflow
- 3/4 HP multi-speed blower, 12" x 9" wheel
- Two round 14" duct collars
- Metal base rails for ground clearance
- Removable sloped drain pan
- Closed-cell base insulation
- Large, easy-access control box
- In-line fused transformer
- Field-supplied 1" x 24" x 24" filter
- Heat strip options up to 20 kW on this listing
Specifications & Manuals
Documentation includes RHPBYB 4 ton cooling and cold-weather heating performance, electrical and heater kit tables, dimensional data for the 37-1/8" cabinet, and warranty details.
Frequently Asked Questions
When does the 4 ton RHPBYB048AJT000NAAUA make sense?
When a load calculation shows roughly 48,000 BTU/h, common in larger homes and homes with long heating or cooling seasons.
How efficient is the 4 ton in cold weather compared with the other larger sizes?
Rheem lists a 2.32 COP at 17°F for the 4 ton, the highest among the 3 to 5 ton RHPBYB models, with 26,200 BTU/h of heating at that temperature.
How is the 4 ton different from the 3.5 ton package heat pump?
Both use the same cabinet, fan, and coil layout. The 4 ton adds about 6,000 BTU/h of cooling, uses 1,600 CFM of airflow, and needs a 50 A maximum breaker versus 45 A.
What size breaker does the 4 ton package heat pump need?
Rheem lists a 37 A minimum circuit ampacity and a 50 A maximum overcurrent protection without electric heat.
How much does the RHPBYB048AJT000NAAUA weigh?
Rheem lists a net weight of 397 lbs and a shipping weight of 422 lbs.
Can the 4 ton unit use a 20 kW heat strip?
Yes. This listing offers 5, 8, 10, 15, and 20 kW options for the 4 ton.
RHPBYB Technical Specifications
RHPBYB Installation Instructions
RHPBYB Consumer Literature
Rheem Package Unit Warranty Certificate