decor decor

Summary

Product #180494: $5,715.00
  • Natural or Liquid Propane (LP) Gas:
  • Copper Line Set or Flush Kit:
  • Thermostat:
  • 42064 / 4 Ton EcoTemp R454B Condenser W5A5S48AKAWA (179440) -- 1
  • 47032 / 5 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM61M24XA (180443) -- 1
  • 47149 / EcoTemp 95% Single Stage 120K BTU Gas Furnace, WFSX120D066B (180480) -- 1
5715
$5,715.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
W5A5S48AKAWA, W5AM61M24XA, WFSX120D066B | Full-size 24-1/2 inch 120K furnace for 4 ton large homes

4 Ton EcoTemp 15 SEER2 95% AFUE 120K BTU Single Stage Gas System W5A5S48AKAWA, W5AM61M24XA, WFSX120D066B

· SKU 180494 · AHRI 215165184 · Split System
SEER2
15
Capacity
48,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $7,430.00

Sale price:

$5,715.00
You save $1,715.00!
  • SKU: 180494
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    15
  • Product Type:
    Split System
  • Tonnage:
    4
  • Operating Mode:
    Gas
  • Refrigerant Type:
    R-454B
  • AFUE %:
    95
  • Airflow Direction:
    Multi-Position
  • Cabinet Width:
    24.5"
  • Manufacturer Warranty:
    10 Years
  • BTUs:
    120,000
  • EcoTemp (ICP) Natural Gas to Liquid Propane 90%+ LP Kit, AGAGC9NPS01E
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 7/8 & 3/8
  • Copper Line Set 50' 7/8 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 4 Ton EcoTemp 14.3 SEER2 R454B Condenser W5A5S48AKAWA
  • 5 Ton EcoTemp R454B Multi-Positional Cased Coil, W5AM61M24XA
  • EcoTemp 95% Single Stage 120K BTU Gas Furnace, WFSX120D066B
Adding to cart… The item has been added

EcoTemp 4 Ton 15 SEER2 AC & 120,000 BTU Condensing Gas Furnace – 24-1/2" Cabinet System

This is the full-size package for large homes in cold climates. The W5A5S48AKAWA 4 ton R-454B condenser and the 24-1/2 in. W5AM61M24XA coil deliver 48,000 BTU of cooling at 15 SEER2 (AHRI 215165184). The WFSX120D066B, the largest furnace in the WFSX series, produces 116,000 BTU of heat at up to 96.1% AFUE through a 1 HP ECM blower with 1,965 CFM of heating airflow. Builders, contractors, and homeowners with roughly 2,000 to 2,500 square feet in northern markets get both a large cooling capacity and the line's biggest burner in one AHRI-matched system.

Is a 4 Ton System with a 120K Furnace the Right Size?

This system suits homes where both seasons are demanding: large two-story homes in the Midwest and Northeast, homes with finished basements, and properties at elevation where the furnace derates 4% per 1,000 ft above 2,000 ft. The 116,000 BTU output covers heat loss beyond what the 100K version (97,000 BTU) can deliver.

Before committing, compare the calculated heat loss with both furnace outputs, and check that supply and return ducts can carry the higher heating airflow. The 24-1/2 in. width and the 70 in. combined height of the furnace and coil also need to fit the mechanical room. A Manual J load calculation plus a duct inspection is the right starting point.

Ideal for: Large homes in cold climates, two-story homes with basements, high-elevation properties, and replacements of an existing 120K furnace and 4 ton AC.

Need more capacity? Step up to the EcoTemp 5 Ton 100K BTU Gas System (W5A5S60AKAWA) or the 5 ton 120K version for more cooling.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, ductwork, climate, elevation, and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condenser W5A5S48AKAWA — 4 Ton Single-Stage R-454B Air Conditioner
Indoor Coil W5AM61M24XA — Multipoise Cased A-Coil, 24-1/2" Wide, Factory TXV
Gas Furnace WFSX120D066B — 120,000 BTU Input / 116,000 BTU Output Condensing Furnace
Furnace Cabinet Width 24-1/2" (35" tall)
Cooling Efficiency 15 SEER2 (AHRI 215165184)
Heating Efficiency 96.1% AFUE Upflow & Horizontal / 95% AFUE Downflow
Refrigerant R-454B
Compressor Single-Stage Scroll Compressor
Condenser Electrical 208/230V, Single Phase, 60 Hz — 29.1 MCA, 50A Max Fuse/Breaker
Furnace Electrical 115V, Single Phase, 60 Hz — 17.4 Unit Ampacity, 12 AWG Min., 20A Breaker
Manufacturer Warranty 10-Year Parts with Timely Registration; 20-Year Furnace Heat Exchanger

The WFSX120D066B furnace and the W5AM61M24XA coil are both 24-1/2 in. wide, and together they stand about 70 in. tall. Because the furnace's heating airflow exceeds 1,800 CFM, the return air must be bottom, two-side, or bottom-plus-side. Plan the return plenum and a 20 x 25 in. minimum filter size from the start. Add a programmable thermostat and a correctly sized line set to complete the installation.

Condenser, Coil & Furnace Features

W5A5S48AKAWA Condenser & W5AM61M24XA Coil

  • 4 ton single-stage scroll compressor with internal thermal overload
  • 15 SEER2 AHRI-certified with this coil and furnace
  • Two-row condenser coil with 17.7 sq. ft. of face area
  • 3,100 CFM direct-drive fan with vertical discharge
  • 75 dBA sound rating, with an optional sound blanket kit
  • Long-line capable to 250 ft equivalent with the required accessories
  • W5AM61M24XA: 35 in. tall, 24-1/2 in. wide, about 92 lb
  • 7/8 in. suction connection with sweat joints ready for brazeless fittings
  • Refrigerant sensor factory installed for R-454B leak detection
  • Split delta plate and front-removable coil for cleaning

WFSX120D066B 120K BTU Condensing Furnace

  • 120,000 BTU input, 116,000 BTU output, six burners
  • 96.1% AFUE upflow and horizontal; 95.0% downflow
  • Widest WFSX "D" cabinet at 24-1/2 in., 35 in. tall
  • 1 HP constant-torque ECM blower: 1,965 CFM heating
  • Cooling airflow range up to 2,240 CFM
  • 17.4 unit ampacity on a 115V, 20 amp circuit
  • Direct vent, single-pipe, or concentric venting options
  • Enhanced 3-digit diagnostics with NFC setup
  • Convertible to propane with the gas conversion kit
  • Meets ENERGY STAR 5.0 South criteria

Specifications & Manuals

Documentation includes condenser, coil, and furnace product data, installation instructions, line-set and venting tables, wiring diagrams, and warranty terms for selection, installation, and service.

Frequently Asked Questions

Does the 120K furnace need a special return-air setup?

Yes. Airflows above 1,800 CFM require a bottom return, two-side returns, or bottom and side returns, with a minimum filter size of 20 x 25 in. The WFSX120D066B's rated heating airflow is 1,965 CFM.

How does this system differ from the 4 ton 100K version?

This version uses the 24-1/2 in. WFSX120D066B with 116,000 BTU of output, compared with 97,000 BTU from the 21 in. 100K furnace. The cooling rating is 15 SEER2 here versus 15.2 SEER2 on the 100K system.

Is a time-delay relay needed with this system?

Most indoor controls already include a blower off-delay, and the WFSX has an adjustable cooling off-delay (90 seconds factory set). A separate time-delay relay is only called for when the AHRI listing specifies one.

Should the condenser be raised off the pad?

The manufacturer's support feet accessory raises the unit 4 in. and is suggested for coastal installations, windy or debris-prone sites, rooftops, and improved sound. It lets dirt flush out from under the base to limit corrosion.

Can the WFSX120D066B be installed downflow?

Yes. It is approved for upflow, downflow, and horizontal left or right. In the downflow position it is rated 95.0% AFUE. Downflow over combustible floors may require a base kit per the installation instructions.

What heating airflow does the WFSX120D066B deliver?

1,965 CFM at a rated heating external static pressure of 0.20 in. w.c., driven by a 1 HP ECM motor and an 11 x 11 in. blower wheel.

Customer Review