decor decor

Summary

Product #180566: $3,520.00
  • Heat Strip:
3520
$3,520.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
BIVB-48MCB-M19X, 8733982677 | 4-Ton IDS Ultra Air Handler Rated for 48,500 BTU of Cold Climate Heat

4 Ton Bosch IDS Ultra Cold Climate R454B Air Handler, BIVB-48MCB-M19X

· SKU 180566 · Air Handler
SEER2
19
Capacity
48,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $4,575.00

Sale price:

$3,520.00
You save $1,055.00!
  • SKU: 180566
  • Availability:
    Usually Ships in 5 to 10 Business Days
  • Shipping:
    Calculated at Checkout
  • SEER2:
    19
  • Product Type:
    Air Handler
  • Tonnage:
    4
  • Refrigerant Type:
    R-454B
  • Manufacturer Warranty:
    10 Years
  • 5kW Bosch Breakered Heat Strip, EHK-05B, WHE0502BX, BI
  • 8kW Bosch Breakered Heat Strip, EHK-08B, WHE0802BX
  • 10kW Bosch Breakered Heat Strip, EHK-08B, WHE1002BX
  • 15kW Bosch Breakered Heat Strip, EHK-15B/WHE1502BX
  • 20kW Bosch Breakered Heat Strip, EHK-20B/WHE2002BX
Adding to cart… The item has been added

4 Ton Bosch IDS Ultra Cold Climate 19 SEER2 R-454B Multi-Position Air Handler, BIVB-48MCB-M19X

The Bosch BIVB-48MCB-M19X turns the 4-5 ton IDS Ultra condenser into a 4 ton cold climate heat pump system. Matched with the BOVB-60MTB-M19E EVI inverter condenser, it's AHRI-rated at 48,500 BTU/h in both cooling and heating, with 19 SEER2, 12 EER2 and 10 HSPF2 (Region IV). Bosch's AHRI table lists the same 48,500 BTU/h at both of its heating test points, consistent with Bosch's rating of 100% heating capacity at 5°F. Inside the 54-1/2" cabinet are a 3/4 HP constant-torque ECM blower, a 5.99 sq. ft. all-aluminum coil, a factory TXV and an A2L refrigerant sensor, sized for larger homes that rely on heat pump heating through northern winters.

Is a 4 Ton Air Handler the Right Size?

As a matched system, this air handler delivers about 48,500 BTU/h of heating and cooling. Rated airflow is 1,560 CFM in cooling and 1,600 CFM in heating. It's a good fit for larger homes where a 3 ton system falls short but a full 5 tons would oversize the ductwork or the cooling load.

Because the BOVB-60MTB-M19E condenser also serves 5 ton systems, the 4 ton indoor match gives the inverter reserve capacity on the coldest days. Confirm your load with a Manual J at the local heating design temperature, and check that the ducts can move about 1,600 CFM without excessive static pressure.

Ideal for: Larger homes in cold and northern climates, 4 ton IDS Ultra systems, and whole-home conversions from oil, propane or electric heat.

Need more capacity? Step up to the 5 Ton Bosch IDS Ultra Cold Climate R-454B Air Handler, BIVB-60MCB-M19X for homes needing up to 55,000 BTU/h of heating.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, static pressure, air leakage and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Indoor Unit BIVB-48MCB-M19X — 4 Ton IDS Ultra Multi-Position Air Handler (Bosch Part No. 8733982677)
Matching Outdoor Unit Sold separately — Bosch BOVB-60MTB-M19E IDS Ultra Cold Climate Heat Pump
Application Cold Climate Split-System Heat Pump Air Handler — Upflow, Downflow, Horizontal Left or Right
Refrigerant R-454B with A2L Refrigerant Sensor
Metering Device Factory-Installed TXV
Blower Motor 3/4 HP Constant-Torque Multi-Speed ECM, 5 Speed Taps
Electrical 208/230V, Single Phase, 60 Hz — 7.8 MCA / 10 A Max Overcurrent (without heat kit)
Line Connections 3/8" Liquid / 7/8" Suction (braze)
Dimensions / Weight 24" D x 22" W x 54-1/2" H — 154 lbs. net

This listing is for the air handler only. For a ready-matched package, choose the 4 Ton Bosch IDS Ultra 19 SEER2 heat pump system. All five Bosch breakered EHK-B kits can run at every blower tap from 1 to 4 in the 48 size up through 10 kW. For heavier backup heat, add the 15 kW EHK-15B or 20 kW EHK-20B heat strip.

Air Handler Features & Matched Heat Pump Options

BIVB-48MCB-M19X IDS Ultra Air Handler

  • 48,500 BTU/h cooling and heating as a matched system
  • 19 SEER2, 12 EER2 and 10 HSPF2 (Region IV) with the BOVB-60MTB-M19E
  • 3/4 HP constant-torque ECM blower designed for four-stage operation
  • Up to 2,137 CFM available at zero static on tap 5
  • 5.99 sq. ft., 4-row all-aluminum evaporator coil
  • A2L refrigerant sensor and factory TXV
  • 7/8" suction and 3/8" liquid braze connections
  • Factory-sealed, fully insulated cabinet
  • 20" x 22" filter in the integrated tool-less rack
  • Dual front panels with slide-out blower and coil

Matched BOVB IDS Ultra Heat Pump & Accessories

  • Pairs with the 4-5 ton BOVB-60MTB-M19E EVI inverter condenser
  • Rated system airflow of 1,600 CFM in heating
  • Hyper-Link (M1 M2) communication with the IDS Ultra condenser
  • Condenser operates in heating down to -13°F
  • Approved for EHK-05B through EHK-20B heat kits
  • Supports 3-stage EHK-15I and EHK-20I electric heat
  • Electrical entry through the top or right side
  • Standard 24 VAC heat pump thermostat compatible
  • Field convertible to downflow or horizontal left
  • Polymer drain pans with UV inhibitor and dual drain fittings

Specifications & Manuals

Product documentation includes technical specifications, airflow and heat kit data, installation instructions, the IDS Ultra brochure, warranty information and the Bosch product catalog to help with equipment selection, installation and service.

Frequently Asked Questions

Why does the 4 ton BIVB-48MCB-M19X pair with a 4-5 ton condenser?

The IDS Ultra outdoor lineup includes a 3 ton and a 4-5 ton condenser. Bosch AHRI-rates the BOVB-60MTB-M19E with this 4 ton air handler at 48,500 BTU/h and 19 SEER2, with the inverter modulating to match the indoor unit.

What separates the 4 ton BIVB-48MCB-M19X from the 3 ton BIVB-36MCB-M19X?

The 4 ton model has a larger 54-1/2" by 22" cabinet, a 5.99 sq. ft. coil versus 4.02, a 3/4 HP blower versus 1/2 HP, and a 7/8" suction connection. It's rated at 48,500 BTU/h versus 36,400 BTU/h of cooling.

Does the 4 ton IDS Ultra system keep its heating capacity in very cold weather?

Bosch rates the IDS Ultra to provide 100% of its heating capacity at 5°F outdoors, and its AHRI table lists 48,500 BTU/h at both heating test points for this pairing. The condenser keeps heating down to -13°F, though output will vary with installation and conditions.

What electrical supply does the BIVB-48MCB-M19X need with a heat kit?

Without electric heat it needs 7.8 MCA on a 10 A circuit. With a heat kit, requirements rise. For example, the single-point EHK-10B calls for 59.9 MCA at 240V with a 60 A breaker, and the EHK-15B and EHK-20B are dual-circuit kits.

What filter size does the 4 ton IDS Ultra air handler use?

It takes a 20" x 22" filter in the built-in, tool-less filter rack. Filters are field supplied. Leave 25" of clearance in front of the unit for filter changes and coil service.

Is the BIVB-48MCB-M19X compatible with other Bosch condensers?

Bosch's IDS Ultra documentation lists this air handler with the BOVB-60MTB-M19E condenser, and Hyper-Link communication requires a matched BIVB19 indoor unit. For AHRI-certified performance, install it with the IDS Ultra condenser.

Customer Review