3 Ton Rheem Endeavor Multi-Positional R454B Cased Coil RCFY3617STANMC (7478)(F)

  • SKU: 3025A
  • Product Type:
    Cased Coil
  • Tonnage:
    3
  • Refrigerant Type:
    R-454B
  • Airflow Direction:
    Multi-Position
  • Cabinet Width:
    17.5"

Discontinued

COIL IS BRAND NEW & COMPLETELY OPERATIONAL
MINOR COSMETIC DAMAGE ONLY
FULL MANUFACTURER'S WARRANTY APPLIES >
3 Ton Rheem Endeavor Multi-Positional Cased Coil RCFY3617STANMC
17.5in Wide Coil

Refrigerant Type: R-454B
Features & Benefits
? Rheem Indoor Furnace cased coils and replacement uncased coils are designed for use with Rheem outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Rheem outdoor units, the coils provide a nominal capacity range from 18,000 to 60,000 BTU
.Constructed of aluminum fins bonded to internally grooved aluminum tubing
.Coils are tested at the factory with an extensive refrigerant leak check
.Coils have copper sweat refrigerant connections
.Feature two sets of 3/4" N.P.T. Condensate drain connections for ease of connection
.Chatleff metering device connections, at inlet and outlet of TXV or EXV and equalizer connections (TXV only)
.Approved for system application with variety of Rheem outdoor units
.Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal-set material
.Compatible with Germicidal Light System (UV resistant)
.Bi-Directional airflow eliminates the need to switch any internal components from horizontal left to right
.Unique drain pan design maximizes application flexibility and condensate removal
.N-Coil design maximizes performance and minimizes height required at installation
.Coils are AHRI certified for system application with a variety of Rheem outdoor units
.Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78% lower GWP than previous-generation refrigerants - with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
.PlusOne Refrigerant Detection System: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation - if excess refrigerant is detected


Click On Links Below For Specifications & Documents:
Technical SpecificationsRA14AY Technical Specifications
Technical SpecificationsRCFY Technical Specifications
Technical SpecificationsR801T Technical Specifications

Technical SpecificationsR801T Installation Instructions
Technical SpecificationsRCFY Installation Instructions
Technical SpecificationsRheem Warranty Certificate
Technical SpecificationsRCFY A2L Sensor Wiring Diagram

SEER2 Explained

"SEER2"stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).
3 Ton Rheem Endeavor Multi-Positional R454B Cased Coil RCFY3617STANMC (7478)(F)
Technical SpecificationsRA14AY Technical Specifications
Technical SpecificationsRCFY Technical Specifications
Technical SpecificationsR801T Technical Specifications

Technical SpecificationsR801T Installation Instructions
Technical SpecificationsRCFY Installation Instructions
Technical SpecificationsRheem Warranty Certificate
Technical SpecificationsRCFY A2L Sensor Wiring Diagram

SEER2 Explained

"SEER2"stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).
3 Ton Rheem Endeavor Multi-Positional R454B Cased Coil RCFY3617STANMC (7478)(F)

Customer Review