This Goodman dual fuel system steps up to a scroll compressor and a 15.2 SEER2 AHRI system rating. It pairs the GLZS4BA3610 3 ton R-32 heat pump with the GR9S960804C 80,000 BTU/h, 97% AFUE gas furnace and a 21"-wide CAPTA3626C3 cased coil. The furnace's 3/4 HP ECM blower supports up to 4 tons of cooling airflow, and the heat pump's 7/8" suction line matches the coil directly, so this is a well-matched, efficient year-round system for 3-bedroom homes.
Is a 3 Ton Dual Fuel System With 80K Heat the Right Size?
A 3 ton heat pump fits cooling loads near 36,000 BTU/h. That covers many 3-bedroom single-story homes, larger townhomes and small offices. The 80K furnace delivers 77,600 BTU/h of heat for four-season and colder climates.
Confirm sizing with separate cooling and heat-loss calculations. Explore other dual fuel heat pump and gas furnace systems to compare tonnages and brands.
Ideal for: 3-bedroom homes, larger townhomes and small offices in four-season or colder climates with gas service.
Need more capacity? Step up to the 3.5 Ton Goodman 80K BTU Dual Fuel Split System with a 1 HP furnace blower.
Recommended applications are general guidelines only. Actual system requirements depend on a load calculation, insulation, ductwork, climate, occupancy, and local code requirements. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | GLZS4BA3610 — 3 Ton R-32 Single-Stage Scroll Heat Pump |
|---|---|
| Gas Furnace | GR9S960804C — 80,000 BTU/h Input / 77,600 BTU/h Output, 97% AFUE, 3/4 HP Multi-Speed ECM |
| Indoor Coil | CAPTA3626C3 — Cased Upflow/Downflow Coil With Factory TXV, 21" W x 26" H |
| System Rating | 15.2 SEER2 (AHRI No. 215217512) |
| Refrigerant | R-32 (83 oz), Outdoor Unit Charged for 15 ft of Tubing |
| Line Sizes | 3/8" Liquid, 7/8" Suction |
| Furnace Configuration | Upflow or Horizontal Left/Right; Direct Vent (2-Pipe) or Non-Direct Vent (1-Pipe) |
| Heat Pump Electrical | 208/230V, Single Phase, 60 Hz (21.5 MCA, 35 A Max Overcurrent) |
| Furnace Electrical | 13.7 MCA, 20 A Max Overcurrent |
The GLZS4BA3610 is the first size in the GLZS4 line with a scroll compressor, and its 7/8" suction line connects directly to the CAPTA3626C3 coil. The 21"-wide GR9S960804C furnace matches the coil width and uses an 11" x 10", 3/4 HP ECM blower with a 25-55°F temperature rise. The 7/8" and 3/8" line sets offered on this page fit this system.
Heat Pump, Furnace & Coil Features
GLZS4BA3610 Heat Pump
- Single-stage scroll compressor
- 36,000 BTU/h nominal cooling and heating
- SmartShift defrost technology
- Factory-installed accumulator, filter drier and crankcase heater
- High-capacity muffler and pressure switches
- 7/8" suction connection matches the coil
- Enhanced aluminum fin coil with 5 mm tubes
- 500-hour salt-spray-approved Architectural Gray finish
- 75 dB sound rating
- 196 lb equipment weight
GR9S960804C Furnace & CAPTA3626C3 Coil
- 80,000 BTU/h input, 97% AFUE
- 77,600 BTU/h heat output
- 11" x 10", 3/4 HP ECM blower for 1.5 to 4 tons
- 25-55°F temperature rise
- Aluminized and stainless-steel heat exchangers
- Cabinet air leakage of 2% or less
- 21" furnace and coil widths stack directly
- Coil rated for 2 to 3 tons with factory TXV
- R-32-optimized all-aluminum coil
- Low water-retention drain pan
Specifications & Manuals
Documentation includes 3 ton scroll heat pump performance data, GR9S96 C-cabinet furnace specifications and airflow, coil dimensions, installation manuals and warranty certificates.
Frequently Asked Questions
Why is the 3 ton system rated 15.2 SEER2?
AHRI rates this specific GLZS4BA3610, GR9S960804C and CAPTA3626C3 combination (AHRI No. 215217512) at 15.2 SEER2, the top of the GLZS4 series.
Does the GLZS4BA3610 use a rotary or scroll compressor?
A scroll compressor. Goodman uses rotary compressors in the 1.5 to 2.5 ton GLZS4 models and switches to scroll compressors starting at 3 tons.
How is the GR9S960804C different from the GR9S960803B?
Both have 80,000 BTU/h inputs. The 0804C uses a 21" cabinet and a larger 11" x 10", 3/4 HP blower rated for up to 4 tons of cooling, with a 25-55°F rise and 97% AFUE. The 0803B is 17-1/2" wide with a 1/2 HP blower for up to 3 tons and 96% AFUE.
Which line set fits the 3 ton dual fuel system?
The GLZS4BA3610 uses a 3/8" liquid line and a 7/8" suction line. The 25 ft and 50 ft 7/8" and 3/8" Rubatex-insulated line sets offered on this page match.
What electrical service does the 3 ton heat pump need?
Goodman lists 21.5 minimum circuit ampacity and a 35 A maximum overcurrent device at 208/230V single phase. Use time-delay fuses or HACR breakers.
Who typically buys a 3 ton dual fuel system with an 80K furnace?
Owners of 3-bedroom homes and larger townhomes in four-season or colder regions who want higher-efficiency cooling plus strong gas heat.
Click On Links Below For Technical Specifications & Manuals:
GLZS4B Technical Specifications
GLXS,GLZS Warranty Certificate
GR9S96 Technical Specifications
CAPTA,CHPTA Technical Specifications
Goodman R32 Cased Coils Warranty Certificate