decor decor

Summary

Product #179358: $3,599.00
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 41903 / 3.5 Ton Rheem R454B Two Stage Heat Pump Condenser RP14AY42AJ2NA (179271) -- 1
  • 41941 / 4 Ton Rheem Two Stage R454B Air Handler RH2TY4821STANNJ (179309) -- 1
3599
$3,599.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?

3.5 Ton Rheem 14.3 SEER2 R454B Two Stage Heat Pump System RP14AY42AJ2N, RH2TY4821STANN

Average Rating:
List price: $4,592.00

Sale price:

$3,599.00
You save $993.00!
  • SKU: 179358
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14.3
  • Product Type:
    Split System
  • Tonnage:
    3.5
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    21"
  • 5 KW heat strip for Rheem Endeavor RH1PZ, RH2TZ, RXBH-1724B05J-1, WRX0502I
  • 7.2 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B07J-1, WRX0752I
  • 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I
  • 15 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724A15J-1, WRX1502BI
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 7/8 & 3/8
  • Copper Line Set 50' 7/8 & 3/8
  • Honeywell T6 Pro Thermostat 3H/2C Programmable TH6320U2008
  • ProStat 7-Day Programmable Digital Thermostat 3H/2C PRS6320
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Honeywell T10 Pro Smart Wi-Fi Touchsrceen Thermostat 3H/2C Programmable w/ Sensor, THX321WFS2001W
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 3.5 Ton Rheem 14.3 SEER2 R454B Two Stage Heat Pump Condenser RP14AY42AJ2NA
  • 4 Ton Rheem Two Stage R454B Air Handler RH2TY4821STANNJ
Adding to cart… The item has been added
Rheem 3.5 Ton 14.3 SEER2 Two Stage Heat Pump System RP14AY42AJ2N, RH2TY4821STANN

R-454B Refrigerant
RP14AY Condenser Features and Benefits
. Two-Stage Scroll Compressor: Features two speeds (high and low) of cooling and heating, providing more precise temperature control, lower humidity and greater efficiency when compared to single stage compressors
. Inverted Reversing Valve: Allows for faster heat transfer with gravity assist shifting and reduced joint stress for increased reliability
. PlusOne Expanded Valve Space:
3 in. - 4 in. - 5 in. service valve space?provides a minimum working area of 27-square inches for easier access
. PlusOne Triple Service Access:
15 in. wide, industry leading corner service access, two fastener, removable corner and individual louver panels?makes repairs easier and faster
. Designing for Sustainability with Low GWP:
For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78% lower GWP than previous-generation refrigerants - with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
. PlusOne Refrigerant Detection System:
An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation - if excess refrigerant is detected

RH2TY Air Handler Features and Benefits
. Quiet Operation: Provided by a cabinet construction with 1.0 inch of foil faced insulation for quieter sound characteristics
. Aluminum Indoor Coil Design: Constructed of aluminum fins bonded to internally grooved aluminum tubing and are more corrosion resistant
. Versatile 4-Way Convertible Compact Design: Allow for upflow, downflow, horizontal left and horizontal right applications even in the smallest of spaces
. Rugged Steel, Compact Cabinet Construction: Designed for added strength and versatility
. Field Installed Auxiliary Heater Kits: Provide exact heat for indoor comfort and include circuit breakers which meet UL and cUL requirements for service disconnect
. Less than 2% Cabinet Air Leakage at 1-inch H2O: When tested in accordance with ASHRAE Standard 193
. Designing for Sustainability with Low GWP: For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems. This new requirement will result in a 78% lower GWP than previous-generation refrigerants - with only minimal changes to system installation. For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
. PlusOne Refrigerant Detection System: An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation - if excess refrigerant is detected