2 Ton Rheem RHMVY2417SEACNJ Modulating Air Handler
The Rheem RHMVY2417SEACNJ is a 2 ton Endeavor Line modulating air handler — Rheem's top variable-speed indoor unit, purpose-built as the EcoNet communicating match for R-454B inverter systems. A truly variable-speed Constant CFM motor and a factory-installed Electronic Expansion Valve (EEV) coil sit in Rheem's most compact 17.5-inch cabinet, delivering the smooth, continuously modulating airflow needed for 18+ SEER2 comfort with an included PlusOne A2L refrigerant sensor on board.
Is the RHMVY2417SEACNJ the Right Air Handler?
This 24,000 BTU air handler is built to pair with a 2 ton R-454B inverter heat pump or air conditioner, making it a fit for compact, well-insulated homes, condos, and single-zone spaces. Its modulating blower operates across roughly 500 to 800 CFM in cooling, slowing for quiet, dehumidifying comfort on mild days and ramping up when the system calls for full capacity.
At just 17.5 inches wide and 42.5 inches tall, this is Rheem's most compact air handler, which makes it especially useful where mechanical-closet or utility space is tight. Proper performance depends on matching the air handler to a compatible outdoor unit and indoor load, so a Manual J calculation and correct system pairing should guide selection.
Ideal for: 2 ton R-454B systems in compact homes and tight installation spaces where cabinet width matters.
Matched outdoor unit: Pair it with the 2 Ton Rheem RP19AY24AJVCA Inverter Heat Pump. Need more coil face and airflow? Compare the wider 2 Ton RHMVY2421MEACNJ.
Recommended applications are general guidelines only. Actual system requirements depend on the matched outdoor unit, insulation, duct design, and your local design temperatures. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Air Handler | RHMVY2417SEACNJ — 2 Ton Endeavor Line Modulating Air Handler |
|---|---|
| Nominal Capacity | 2.0 Tons / 24,000 BTU |
| Cabinet Size | 17.5 in. W × 42.5 in. H (most compact width) |
| Blower Motor | 1/3 HP truly variable-speed Constant CFM ECM, modulating (300–1300 RPM) |
| Rated Airflow | ~500–800 CFM (cooling) with a matched 2 ton R-454B system |
| Indoor Coil | Factory-installed aluminum coil with Electronic Expansion Valve (EEV) |
| Line Connections | Liquid 3/8 in., Vapor 3/4 in. (copper sweat) |
| Refrigerant | R-454B (low-GWP A2L) |
| Refrigerant Detection | Factory-installed PlusOne A2L sensor with mitigation (included) |
| Controls | EcoNet Enabled communicating board with PlusOne Bluetooth diagnostics |
| Installation | 4-way convertible — upflow, downflow, horizontal left/right |
| Electrical | 208/240V, 1 Ph, 60 Hz — MCA 4, Max Breaker 15A (blower only); accepts field-installed heat kits |
| Shipping Weight | ~105 lbs. |
| Warranty | 10-Year Parts Limited Warranty (registration required) |
The indoor coil is factory-installed, leak-checked, and built from aluminum fins bonded to internally grooved aluminum tubing. The EEV, driven by a factory-installed pressure transducer, meters refrigerant precisely for full heat-pump compatibility, and the cabinet is tested to less than 2% air leakage at 1-inch H2O per ASHRAE Standard 193.
Airflow & Design Features
Airflow & Efficiency
- Truly variable-speed Constant CFM modulating blower
- Electronic Expansion Valve for precise refrigerant metering
- Rated ~500–800 CFM for a 2 ton system
- Part of 18+ SEER2 R-454B inverter systems
- Aluminum coil with low air-side pressure drop
- Less than 2% cabinet air leakage at 1-inch H2O
Controls, Safety & Serviceability
- EcoNet Enabled communicating control board
- PlusOne Bluetooth diagnostics and dip-switch-free commissioning
- Included PlusOne A2L refrigerant detection sensor
- Compact 17.5-inch steel cabinet for the tightest spaces
- 4-way convertible with 1.0-inch foil-faced insulation
- Slide-out blower and molded corrosion-resistant drain pan
Specifications & Manuals
Product documentation includes technical specifications, installation instructions, a parts list, and warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
What makes the RHMVY2417SEACNJ a "modulating" air handler?
Its truly variable-speed Constant CFM motor continuously adjusts airflow to match the system's demand instead of running at fixed speeds. Paired with an EcoNet communicating system, this delivers steadier temperatures, quieter operation, and better humidity control.
How compact is the 17.5-inch cabinet on this 2 ton unit?
At 17.5 inches wide and 42.5 inches tall, the RHMVY2417SEACNJ is Rheem's smallest air handler, making it a strong choice for tight mechanical closets and utility spaces where a wider 21-inch unit would not fit.
Which condenser pairs with the RHMVY2417SEACNJ?
It is designed to match a 2 ton R-454B outdoor unit such as the Rheem RP19AY24AJVCA inverter heat pump or a matched RA19AY air conditioner. Correct outdoor-to-indoor matching is required for rated performance.
Does this air handler include a refrigerant leak sensor?
Yes. This base model includes a factory-installed PlusOne A2L refrigerant detection sensor with a mitigation board that automatically pauses outdoor unit operation if excess refrigerant is detected. (The "L" version of this model ships without the sensor.)
Can the RHMVY2417SEACNJ be installed in upflow, downflow, or horizontal positions?
Yes. It is field convertible in four ways — upflow, downflow, horizontal left, and horizontal right — so a single unit adapts to most installation orientations.
Does commissioning require setting DIP switches?
No. The RHMVY supports dip-switch-free commissioning through Bluetooth using the Rheem Contractor App, and PlusOne diagnostics simplify set-up, monitoring, and troubleshooting during installation.



RHMV Technical Specifications
Rheem Warranty Certificate