2 Ton Goodman 15.2 SEER2 R-32 60K BTU Two-Stage Gas Package Unit GPGM52406031
The Goodman GPGM52406031 puts two-stage comfort in both seasons into a compact 2 ton package unit. A two-stage scroll compressor delivers 23,600 BTUh of total cooling at 15.2 SEER2 and 11.5 EER2. A two-stage gas valve fires the furnace at 45,000 or 60,000 BTU input, producing 36,450 to 48,600 BTU of heat at 81% AFUE. A variable-speed ECM blower, a corrosion-resistant T-140 aluminized steel heat exchanger, and Low NOx (40 ng/J) compliance round out a high-efficiency, all-in-one system for small homes and light commercial spaces. Shop more Goodman equipment.
Is a 2 Ton Two-Stage Gas Package Unit the Right Size?
A 2 ton unit fits cooling loads of about 22,000 to 24,000 BTUh, typical of compact single-story homes, manufactured homes, and small offices. Two-stage operation is the key difference here. On mild days, the compressor and burners run on low stage for longer, quieter cycles that even out temperatures and remove more humidity. On the hottest and coldest days, they switch to full capacity.
Heating should match your home's heat loss. The 45,000/60,000 BTU input furnace suits many small homes in mixed climates, and its 25–55°F temperature rise is the lowest in the GPGM5 line. Start sizing with our AC tonnage and BTU calculator, then confirm with a load calculation.
Ideal for: Small homes, manufactured homes, and small offices that want two-stage comfort and quieter, more even heating and cooling from one gas package unit.
Need more capacity? Step up to the 2.5 Ton Goodman Two-Stage Gas Package Unit GPGM53008031 for more cooling and an 80K BTU furnace.
Recommended applications are general guidelines only. Actual system requirements depend on insulation, ductwork, climate, window area, occupancy, and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Package Unit | GPGM52406031: 2 Ton Two-Stage Gas/Electric Package Unit |
|---|---|
| Cooling Capacity | 23,600 BTUh Total / 18,370 BTUh Sensible, 780 CFM |
| Gas Heating | 60,000 / 45,000 BTU Input (Two-Stage); 48,600 / 36,450 BTU Output; 81% AFUE |
| Efficiency | 15.2 SEER2 / 11.5 EER2 |
| Refrigerant | R-32, Factory Charged (58 oz.), TXV Metering |
| Compressor | Two-Stage Scroll Compressor |
| Airflow Configuration | Convertible Horizontal or Downflow |
| Electrical | 208/230V, Single Phase, 60 Hz; 17.2 MCA, 25 Amp Max Overcurrent |
The GPGM52406031 uses Goodman's medium chassis (47 x 51 inch footprint) with 16 x 16 inch supply and return openings, and ships at about 380 lb. It is light enough that 2–4 ton GPGM5 models fit in a standard-size pickup truck. It ships set up for natural gas and converts to propane with an accessory kit. For round horizontal ductwork, use the SQRPGH101/102 square to round adapter. Browse more 2 ton gas package units.
Cooling & Gas Heating Features
GPGM52406031 Air Conditioning Section
- Two-stage scroll compressor (10 RLA / 67.5 LRA)
- 23,600 BTUh total cooling at 15.2 SEER2 / 11.5 EER2
- Variable-speed ECM indoor blower, 1/2 HP, 780 CFM nominal
- TXV refrigerant metering
- All-aluminum, 3-row evaporator coil
- Copper tube/aluminum fin condenser coil
- 58 oz. factory R-32 charge
- Loss-of-charge protection and high-pressure switch
- Self-diagnostics on blower operation and safety circuits
- AHRI Certified, UL Listed
GPGM52406031 Gas Furnace Section
- Two-stage gas valve: 45,000 / 60,000 BTU input
- 36,450 / 48,600 BTU heating output at 81% AFUE
- T-140 aluminized steel tubular heat exchanger resists corrosion
- Three-burner design with power-assisted combustion
- Microprocessor-controlled direct spark ignition
- 25–55°F temperature rise range
- Meets California Low NOx standard (40 ng/J)
- Natural gas standard, propane conversion with accessory kit
- 99-year heat exchanger limited warranty with registration
- Insulated, UV-resistant powder-painted steel cabinet
Specifications & Manuals
Product documentation includes GPGM5 technical specifications with expanded cooling, airflow, dimensional, and accessory data, installation instructions, and Goodman warranty terms to assist with equipment selection, installation, and service.
Frequently Asked Questions
What does two-stage heating mean on the GPGM52406031?
The two-stage gas valve lets the furnace fire at 45,000 BTU input on low stage for most of the heating season, and at 60,000 BTU input when more heat is needed. Low-stage operation gives longer, quieter cycles and more even temperatures.
Why does the 2 ton GPGM5 have a different temperature rise range?
The 2 ton's smaller 60K furnace is rated for a 25–55°F rise. The 2.5 through 5 ton models, with larger furnaces, are rated for 35–65°F. Set airflow so the actual rise stays within range.
Does the GPGM52406031 meet Low NOx requirements?
Yes. Goodman states that all GPGM5 models comply with the California Low NOx emission standard of 40 ng/J NOx. Check local air district rules for stricter requirements.
Will the 2 ton GPGM5 fit in a pickup truck?
Goodman states that the 2–4 ton GPGM5 models fit in a standard-size pickup truck. The 2 ton weighs about 380 lb shipped and has 2-inch base rails for easier handling.