2 Ton Bosch IDS Light 15 SEER2 R-454B Heat Pump Inverter Condenser, BOVB-24RTB-M15S
The Bosch BOVB-24RTB-M15S is a 24,000 BTU inverter heat pump condenser from the Bosch IDS Light series, built for R-454B split systems that need efficient heating and cooling from one outdoor unit. A standard inverter compressor adjusts its output to the home's load instead of cycling fully on and off, and an electronic expansion valve (EEV) meters refrigerant precisely. It delivers 24,000 BTU/h nominal cooling and heating and keeps heating at outdoor temperatures as low as 3°F. Matched with Bosch's IDS Premium air handler, it reaches an AHRI-certified 18.0 SEER2. It's a strong choice for smaller homes, condos, additions and replacement projects moving from R-410A to R-454B. Explore more Bosch heating and cooling equipment.
Is a 2 Ton Heat Pump the Right Size?
A 2 ton heat pump is sized for a heating and cooling load of about 24,000 BTU/h. That usually means a smaller home, condo, apartment, finished bonus room or a single zone of a larger house. Because the BOVB-24RTB-M15S is an inverter unit, it can run at reduced speed for long stretches. This avoids the short cycling that oversized single-stage equipment often suffers in smaller spaces.
Square footage alone shouldn't decide the size. Insulation levels, window area and orientation, duct condition, air leakage, ceiling height, local climate and how many people live in the home all change the real load. A Manual J load calculation is the most reliable way to confirm that 24,000 BTU/h matches both your design cooling and your design heating needs.
Ideal for: Smaller single-family homes, condos and townhomes, room additions, upstairs zones and R-410A replacement projects that need about 2 tons of heating and cooling.
Need more capacity? Step up to the 3 Ton Bosch IDS Light Heat Pump Inverter Condenser, BOVB-36RTB-M15S for homes whose load calculation calls for 34,000+ BTU/h.
Recommended heat pump applications are general guidelines only. Actual system requirements depend on insulation, climate, ductwork, air leakage, window area and occupancy. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Unit | BOVB-24RTB-M15S — 2 Ton IDS Light Heat Pump Inverter Condenser (Bosch Part No. 8733982681) |
|---|---|
| Indoor Unit | Sold separately — matched indoor options listed below |
| Application | Ducted Split-System Heat Pump, Heating & Cooling |
| Refrigerant | R-454B (A2L) — 4 lbs. 13 oz. spec-sheet charge |
| Compressor | Standard Inverter Compressor |
| Defrost | Demand Defrost Control |
| Electrical | 208/230V, Single Phase, 60 Hz — 21.8 MCA / 35 A Max Overcurrent Protection |
| Line Sizes | 3/8" Liquid / 3/4" Suction — up to 100 ft line length, 50 ft elevation |
| Dimensions / Weight | 28" x 28" x 24-15/16" — 122 lbs. net |
This listing is for the outdoor condenser only. Pair the BOVB-24RTB-M15S with a Bosch IDS Light BIVA-24RXB-M15X air handler for 15.2 SEER2, or with an IDS Premium BIVB-24RCB-M20X for 18.0 SEER2 and 9 HSPF2. For gas-heat homes, Bosch has also AHRI-rated it with the Bosch BMAC2430ABTA 14.5" cased coil and the BMAC2430BBTA 17.5" cased coil over a Bosch BGH97 furnace, for 16.0 SEER2. Its compact 28-inch-square cabinet fits on tight side yards and small condenser pads.
Condenser Features & Matched Indoor Options
BOVB-24RTB-M15S Outdoor Inverter Condenser
- 24,000 BTU/h nominal cooling and 24,000 BTU/h nominal heating
- Standard inverter compressor modulates output to match the load
- Electronic expansion valve (EEV) for precise refrigerant metering
- Heats at outdoor temperatures from 3°F to 86°F; cools from 40°F to 120°F
- Demand Defrost Control uses coil and ambient sensors to start defrost only when needed
- Compressor crankcase heater for cold-weather protection
- High pressure switch and low pressure transducer
- Compressor liquid return, compression ratio and high temperature protection
- High/low voltage and over-current protection
- Rated sound level of 59.0 dB(A) at minimum load and 74.9 dB(A) at full load
IDS Light & IDS Premium Indoor Pairings
- BIVA-24RXB-M15X IDS Light air handler: 15.2 SEER2 AHRI rating
- BIVB-24RCB-M20X IDS Premium air handler: 18.0 SEER2, 12 EER2, 9 HSPF2
- BMAC2430ABTA / BMAC2430BBTA cased coils with Bosch BGH97 furnace: 16.0 SEER2
- Indoor unit must include refrigerant leak detection for A2L R-454B systems
- Works with conventional 24V thermostats using 18 AWG minimum wire
- 2H thermostat supports single-stage electric auxiliary heat; 3H supports two stages
- Optional IDS Gateway (Part No. 8733982717) adds Bosch EasyAir app connectivity
- Connectivity requires an IDS Premium air handler, BMXF modular blower or BGH97 furnace
- Gateway enables utility demand-response signals where offered
- Browse compatible heat pump thermostats and controls
Specifications & Manuals
Product documentation includes technical specifications, AHRI matchup data, installation and operating instructions, a parts list, warranty terms and the Bosch product catalog to help with equipment selection, installation and service.
Frequently Asked Questions
What size home is the BOVB-24RTB-M15S designed for?
It's sized for homes or zones with a heating and cooling load of about 24,000 BTU/h, such as smaller houses, condos, townhomes and additions. Insulation, climate and ductwork change the real load, so a Manual J calculation is the best way to confirm the size.
How is the 2 ton BOVB-24RTB-M15S different from the 3 ton BOVB-36RTB-M15S?
The BOVB-24RTB-M15S is rated at 24,000 BTU/h, needs a smaller 21.8 MCA / 35 A circuit and weighs 122 lbs. The 3 ton BOVB-36RTB-M15S is rated at 34,200 BTU/h cooling and 34,600 BTU/h heating, with a 25.8 MCA / 40 A circuit. Both use the same 28" x 28" cabinet footprint.
Which indoor unit gives the BOVB-24RTB-M15S its highest efficiency?
The Bosch IDS Premium BIVB-24RCB-M20X air handler gives the highest AHRI rating: 18.0 SEER2, 12 EER2 and 9 HSPF2. With the IDS Light BIVA-24RXB-M15X air handler, the system is rated at 15.2 SEER2.
Does this heat pump need a communicating thermostat?
No. The installation instructions show conventional 24V thermostat wiring with 18 AWG minimum conductors. A 2H thermostat supports single-stage electric auxiliary heat and a 3H thermostat supports two-stage auxiliary heat.
Will the BOVB-24RTB-M15S keep heating in cold weather?
Bosch lists a heating operating range of 3°F to 86°F outdoor temperature. Demand Defrost Control and a compressor crankcase heater help keep it running reliably in winter. In colder climates, many installers add electric auxiliary heat for the coldest days.
Why does the indoor unit need refrigerant leak detection?
R-454B is classified as an A2L (mildly flammable) refrigerant. Bosch's installation instructions require this outdoor unit to be paired with an indoor unit that has refrigerant leak detection, and installation must be done by a licensed HVAC contractor.
Bosch IDS Light Condenser Technical Specifications
Bosch IDS Light Condenser Installation Instructions
Bosch IDS Light Condenser Parts List
Bosch IDS Light Warranty
Bosch Catalog