2.5 Ton Goodman 14.3 SEER2 R-32 Dual Fuel Split System, 60K BTU Furnace, GLZS4BA3010, GR9S960603B, CAPTA3626B3
This Goodman dual fuel system pairs the GLZS4BA3010 2.5 ton R-32 heat pump with the GR9S960603B 60,000 BTU/h, 97% AFUE gas furnace and a CAPTA3626B3 cased coil, for a 14.3 SEER2 AHRI-rated system. The heat pump handles summer cooling and mild-weather heating, and the furnace's 58,200 BTU/h output takes over on colder days. Furnace and coil share a 17-1/2" width for a clean stacked install, making this a well-matched year-round system for mid-size homes.
Is a 2.5 Ton Dual Fuel System With 60K Heat the Right Size?
A 2.5 ton heat pump fits cooling loads near 30,000 BTU/h. That typically means 2- to 3-bedroom homes, ranch homes and larger townhomes. The 60K furnace suits moderate winters, where heating needs are similar to or a bit higher than the cooling load.
Base the cooling and furnace sizes on separate load and heat-loss calculations. For colder climates, the 2.5 ton 80K BTU dual fuel system keeps the same heat pump and coil with more furnace output.
Ideal for: 2- to 3-bedroom homes, ranch homes and townhomes in moderate four-season climates with gas service.
Need more capacity? Step up to the 3 Ton Goodman 15.2 SEER2 80K BTU Dual Fuel Split System with a scroll compressor heat pump.
Recommended applications are general guidelines only. Actual system requirements depend on a load calculation, insulation, ductwork, climate, occupancy, and local code requirements. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | GLZS4BA3010 — 2.5 Ton R-32 Single-Stage Heat Pump |
|---|---|
| Gas Furnace | GR9S960603B — 60,000 BTU/h Input / 58,200 BTU/h Output, 97% AFUE, Multi-Speed ECM |
| Indoor Coil | CAPTA3626B3 — Cased Upflow/Downflow Coil With Factory TXV, 17-1/2" W x 26" H |
| System Rating | 14.3 SEER2 (AHRI No. 215218828) |
| Refrigerant | R-32 (81 oz), Outdoor Unit Charged for 15 ft of Tubing |
| Line Sizes | 3/8" Liquid, 3/4" Suction |
| Furnace Configuration | Upflow or Horizontal Left/Right; Direct Vent (2-Pipe) or Non-Direct Vent (1-Pipe) |
| Heat Pump Electrical | 208/230V, Single Phase, 60 Hz (15.0 MCA, 25 A Max Overcurrent) |
| Furnace Electrical | 10.1 MCA, 15 A Max Overcurrent |
The GLZS4BA3010 uses a single-stage rotary compressor, SmartShift defrost and factory-installed protection components, at a 175 lb equipment weight. The furnace's 11" x 8" ECM blower supports 1.5 to 3 tons of cooling airflow, and the CAPTA3626B3 coil (rated 2 to 3 tons) includes a factory TXV. The coil has a 7/8" suction connection, so plan a reducer to the heat pump's 3/4" suction line.
Heat Pump, Furnace & Coil Features
GLZS4BA3010 Heat Pump
- 30,000 BTU/h nominal cooling and heating
- Single-stage rotary compressor
- SmartShift quiet defrost technology
- Enhanced aluminum fin coil with 5 mm tubes
- Accumulator, filter drier and crankcase heater factory-installed
- High-capacity muffler
- High- and low-pressure switches
- Galvanized cabinet with 500-hour salt-spray-rated paint
- Hurricane-wind rated when anchored
- AHRI Certified and ETL Listed
GR9S960603B Furnace & CAPTA3626B3 Coil
- 60,000 BTU/h input, 97% AFUE
- Multi-speed ECM blower for up to 3 tons of cooling
- 30-60°F temperature rise
- Aluminized-steel primary and stainless-steel secondary heat exchangers
- Self-diagnostic board with LED fault code memory
- 17-1/2" furnace and coil widths stack directly
- Coil rated for 2 to 3 tons
- Factory-installed TXV and R-32 sensor
- 21" coil depth for easier attic access
- Rust-resistant thermoplastic drain pan
Specifications & Manuals
Documentation includes GLZS4 heat pump, GR9S96 furnace and CAPTA coil specifications, expanded performance data, wiring, installation instructions and warranty certificates.
Frequently Asked Questions
How does the 2.5 ton GLZS4BA3010 differ from the 2 ton heat pump?
The 2.5 ton provides 30,000 BTU/h of nominal capacity, holds 81 oz of R-32 and weighs 175 lbs. It needs a 15.0 MCA circuit with a 25 A maximum overcurrent device, compared with 11.2 MCA and 15 A on the 2 ton. Both use rotary compressors and 3/4" suction lines.
Why is this system rated 14.3 SEER2 instead of 14.5?
SEER2 is rated for each specific heat pump, coil and furnace combination. AHRI lists this 2.5 ton pairing (AHRI No. 215218828) at 14.3 SEER2.
What size coil comes with the 2.5 ton system?
The CAPTA3626B3 is 17-1/2" wide, 21" deep and 26" tall, rated for 2 to 3 tons, with a 3/8" liquid and 7/8" suction connection.
Can the GR9S960603B blower handle 2.5 tons of cooling?
Yes. Its multi-speed ECM blower is rated for 1.5 to 3 tons of cooling airflow, so 2.5 tons is well within range.
How much refrigerant is in the GLZS4BA3010?
The heat pump ships with 81 oz of R-32, enough for 15 ft of 3/8" liquid line. The installer adjusts the charge for longer runs following Goodman's final charge procedure.
Who typically chooses a 2.5 ton dual fuel system with a 60K furnace?
Owners of 2- to 3-bedroom homes and townhomes in moderate climates who want heat pump efficiency for most of the year with dependable gas heat in winter.
Click On Links Below For Technical Specifications & Manuals:
GLZS4B Technical Specifications
GLXS,GLZS Warranty Certificate
GR9S96 Technical Specifications
CAPTA,CHPTA Technical Specifications