decor decor

Summary

Product #123172: $4,280.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • 42015 / 2.5 Ton Goodman R32 Heat Pump Condenser GLZS4BA3010 (179391) -- 1
  • 45210 / Goodman 96% Single Stage 60K BTU Gas Furnace, GR9S960603BN (90212) -- 1
  • 42095 / 3 Ton Goodman R32 17.5" Vertical Cased Coil CAPTA3626B3 (179473) -- 1
  • Natural or Liquid Propane (LP) Gas:
  • Copper Line Set or Flush Kit:
  • Thermostats:
4280
$4,280.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GLZS4BA3010, GR9S960603B, CAPTA3626B3 | Mid-Size Dual Fuel for Moderate Winters

2.5 Ton Goodman 14.3 SEER2 96% AFUE 60K BTU Dual Fuel Split, GLZS4BA3010, GR9S960603B, CAPTA3626B3

· SKU 123172 · AHRI 215218828 · Split System
SEER2
14.3
Capacity
30,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $6,090.00

Our price:

$5,661.00

Sale price:

$4,280.00
You save $1,810.00!

Click For Sale Price

Sale price:

$4,280.00

List price:

$6,090.00

Our price:

$5,661.00
You save: 24% ($1,810.00)
  • SKU: 123172
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14.3
  • Product Type:
    Split System
  • Tonnage:
    2.5
  • Operating Mode:
    Dual Fuel
  • Refrigerant Type:
    R-32
  • AFUE %:
    96
  • BTUs:
    60,000
  • Cabinet Width:
    17.5”
  • Airflow Direction:
    Upflow/Horizontal
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 2.5 Ton Goodman 14.3 SEER2 R32 Heat Pump Condenser GLZS4BA3010
  • Goodman 96% Single Stage 60K BTU Gas Furnace, GR9S960603BN
  • 3 Ton Goodman R32 17.5" Vertical Cased Coil CAPTA3626B3
  • Easy One-Step 16 oz Ultra Flush Refill Only No Hardware image main
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • ProStat 7-Day Programmable Digital Thermostat 3H/2C PRS6320
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
Adding to cart… The item has been added

2.5 Ton Goodman 14.3 SEER2 R-32 Dual Fuel Split System, 60K BTU Furnace, GLZS4BA3010, GR9S960603B, CAPTA3626B3

This Goodman dual fuel system pairs the GLZS4BA3010 2.5 ton R-32 heat pump with the GR9S960603B 60,000 BTU/h, 97% AFUE gas furnace and a CAPTA3626B3 cased coil, for a 14.3 SEER2 AHRI-rated system. The heat pump handles summer cooling and mild-weather heating, and the furnace's 58,200 BTU/h output takes over on colder days. Furnace and coil share a 17-1/2" width for a clean stacked install, making this a well-matched year-round system for mid-size homes.

Is a 2.5 Ton Dual Fuel System With 60K Heat the Right Size?

A 2.5 ton heat pump fits cooling loads near 30,000 BTU/h. That typically means 2- to 3-bedroom homes, ranch homes and larger townhomes. The 60K furnace suits moderate winters, where heating needs are similar to or a bit higher than the cooling load.

Base the cooling and furnace sizes on separate load and heat-loss calculations. For colder climates, the 2.5 ton 80K BTU dual fuel system keeps the same heat pump and coil with more furnace output.

Ideal for: 2- to 3-bedroom homes, ranch homes and townhomes in moderate four-season climates with gas service.

Need more capacity? Step up to the 3 Ton Goodman 15.2 SEER2 80K BTU Dual Fuel Split System with a scroll compressor heat pump.

Recommended applications are general guidelines only. Actual system requirements depend on a load calculation, insulation, ductwork, climate, occupancy, and local code requirements. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump GLZS4BA3010 — 2.5 Ton R-32 Single-Stage Heat Pump
Gas Furnace GR9S960603B — 60,000 BTU/h Input / 58,200 BTU/h Output, 97% AFUE, Multi-Speed ECM
Indoor Coil CAPTA3626B3 — Cased Upflow/Downflow Coil With Factory TXV, 17-1/2" W x 26" H
System Rating 14.3 SEER2 (AHRI No. 215218828)
Refrigerant R-32 (81 oz), Outdoor Unit Charged for 15 ft of Tubing
Line Sizes 3/8" Liquid, 3/4" Suction
Furnace Configuration Upflow or Horizontal Left/Right; Direct Vent (2-Pipe) or Non-Direct Vent (1-Pipe)
Heat Pump Electrical 208/230V, Single Phase, 60 Hz (15.0 MCA, 25 A Max Overcurrent)
Furnace Electrical 10.1 MCA, 15 A Max Overcurrent

The GLZS4BA3010 uses a single-stage rotary compressor, SmartShift defrost and factory-installed protection components, at a 175 lb equipment weight. The furnace's 11" x 8" ECM blower supports 1.5 to 3 tons of cooling airflow, and the CAPTA3626B3 coil (rated 2 to 3 tons) includes a factory TXV. The coil has a 7/8" suction connection, so plan a reducer to the heat pump's 3/4" suction line.

Heat Pump, Furnace & Coil Features

GLZS4BA3010 Heat Pump

  • 30,000 BTU/h nominal cooling and heating
  • Single-stage rotary compressor
  • SmartShift quiet defrost technology
  • Enhanced aluminum fin coil with 5 mm tubes
  • Accumulator, filter drier and crankcase heater factory-installed
  • High-capacity muffler
  • High- and low-pressure switches
  • Galvanized cabinet with 500-hour salt-spray-rated paint
  • Hurricane-wind rated when anchored
  • AHRI Certified and ETL Listed

GR9S960603B Furnace & CAPTA3626B3 Coil

  • 60,000 BTU/h input, 97% AFUE
  • Multi-speed ECM blower for up to 3 tons of cooling
  • 30-60°F temperature rise
  • Aluminized-steel primary and stainless-steel secondary heat exchangers
  • Self-diagnostic board with LED fault code memory
  • 17-1/2" furnace and coil widths stack directly
  • Coil rated for 2 to 3 tons
  • Factory-installed TXV and R-32 sensor
  • 21" coil depth for easier attic access
  • Rust-resistant thermoplastic drain pan

Specifications & Manuals

Documentation includes GLZS4 heat pump, GR9S96 furnace and CAPTA coil specifications, expanded performance data, wiring, installation instructions and warranty certificates.

Frequently Asked Questions

How does the 2.5 ton GLZS4BA3010 differ from the 2 ton heat pump?

The 2.5 ton provides 30,000 BTU/h of nominal capacity, holds 81 oz of R-32 and weighs 175 lbs. It needs a 15.0 MCA circuit with a 25 A maximum overcurrent device, compared with 11.2 MCA and 15 A on the 2 ton. Both use rotary compressors and 3/4" suction lines.

Why is this system rated 14.3 SEER2 instead of 14.5?

SEER2 is rated for each specific heat pump, coil and furnace combination. AHRI lists this 2.5 ton pairing (AHRI No. 215218828) at 14.3 SEER2.

What size coil comes with the 2.5 ton system?

The CAPTA3626B3 is 17-1/2" wide, 21" deep and 26" tall, rated for 2 to 3 tons, with a 3/8" liquid and 7/8" suction connection.

Can the GR9S960603B blower handle 2.5 tons of cooling?

Yes. Its multi-speed ECM blower is rated for 1.5 to 3 tons of cooling airflow, so 2.5 tons is well within range.

How much refrigerant is in the GLZS4BA3010?

The heat pump ships with 81 oz of R-32, enough for 15 ft of 3/8" liquid line. The installer adjusts the charge for longer runs following Goodman's final charge procedure.

Who typically chooses a 2.5 ton dual fuel system with a 60K furnace?

Owners of 2- to 3-bedroom homes and townhomes in moderate climates who want heat pump efficiency for most of the year with dependable gas heat in winter.

Customer Review