decor decor

Summary

Product #180010: $3,180.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 42061 / 2.5 Ton EcoTemp R454B Condenser W5A5S30AKAWA (179437) -- 1
  • 45975 / 2.5 Ton EcoTemp R454B Air Handler FMA5X3000AL ( 179785) -- 1
3180
$3,180.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
W5A5S30AKAWA, FMA5X3000AL | Whisper-Smooth ECM Airflow for Two-Bath Condos

2.5 Ton EcoTemp 16 SEER2 R454B Central Wall Mount Apartment/Condo Type System W5A5S30AKAWA, FMA5X3000AL

· SKU 180010 · AHRI 214878691 · Split System
SEER2
16
Capacity
30,000 BTU
Refrigerant
R-454B

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $4,135.00

Sale price:

$3,180.00
You save $955.00!
  • SKU: 180010
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    16
  • Product Type:
    Split System
  • Tonnage:
    2.5
  • Operating Mode:
    Cool Only with Electric Heat
  • Refrigerant Type:
    R-454B
  • Cabinet Width:
    22"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • EcoTemp 5 kW Breakered Heat Strip Apartment/Condo Style Air Handler models FMA4X & FMA4P EHK205B/ WFM0502B
  • EcoTemp 7.5 kW Breakered Heat Strip Apartment/Condo Style Air Handler models FMA4X & FMA4P EHK208B/ WFM0802B
  • EcoTemp 10 kW Breakered Heat Strip Apartment/Condo Style Air Handler models FMA4X & FMA4P EHK210B/ WFM1002B
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 3/4 & 3/8
  • Copper Line Set 50' 3/4 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • 2.5 Ton EcoTemp 14.3 SEER2 R454B Condenser W5A5S30AKAWA
  • 2.5 Ton EcoTemp R454B Wall Mount Apartment/Condo Type ECM Motor Air Handler FMA5X3000AL
Adding to cart… The item has been added

2.5 Ton EcoTemp 16 SEER2 R-454B High-Efficiency Wall Mount Apartment/Condo AC System

The EcoTemp W5A5S30AKAWA condenser and FMA5X3000AL ECM fan coil team up for 2.5 tons (30,000 BTU) of AHRI-certified cooling at 16 SEER2 (AHRI #214878691), a full SEER2 point higher than the matching PSC package. Inside the larger 22" wide FMA5 cabinet, a 1/2 HP five-tap ECM blower moves a nominal 1,100 CFM across a 3.0 sq ft aluminum coil, giving two- and three-bedroom condos strong, even airflow with lower blower energy use. Built on R-454B refrigerant with a scroll compressor outdoors, it is a premium closet-mounted solution for condo owners, rental investors, and HVAC contractors who want efficiency without sacrificing capacity.

Is a 2.5 Ton High-Efficiency Wall Mount AC System the Right Size?

A 2.5 ton system frequently fits living spaces between roughly 1,200 and 1,500 square feet, typical of two-bedroom, two-bath condos and many smaller three-bedroom apartments. Use that as a sanity check only; the true answer comes from a cooling load calculation for the specific unit.

Larger multifamily floor plans tend to have more glass, longer duct runs, and more people, all of which add load. Supply and return duct sizing also deserves attention at this size, because 1,100 CFM through undersized ducts creates noise and reduces delivered capacity. The FMA5X3000AL's five ECM airflow taps give installers room to match airflow to the duct system and the home's dehumidification needs.

Ideal for: Two-bedroom, two-bath condos, smaller three-bedroom apartments, high-end rental units marketed on efficiency, condo renovations, and efficiency upgrades of 2.5 ton apartment-style closet systems.

Need more capacity? Step up to the 3 Ton EcoTemp 16 SEER2 W5A5S36AKDWA & FMA5X3600AL Wall Mount System for the largest condos requiring additional cooling capacity.

Recommended applications are general guidelines only. Actual system requirements depend on insulation, windows, sun exposure, ceiling height, climate, occupancy, and ductwork. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Condensing Unit W5A5S30AKAWA — 2.5 Ton Single-Stage R-454B Air Conditioner
Indoor Air Handler FMA5X3000AL Multifamily Wall-Hung Fan Coil (ECM Motor)
Application High-Efficiency Central Air Conditioning for Apartments & Condos — 16 SEER2, AHRI #214878691
Refrigerant R-454B
Compressor Single-Stage Scroll Compressor
Blower Motor 1/2 HP 5-Speed ECM (Constant Torque), Direct Drive
Electrical 208-230V, Single Phase, 60 Hz Condensing Unit
Air Handler Electrical 208/230V, Single Phase, 60 Hz

Indoors, the FMA5X3000AL ECM apartment air handler ships on tap 2 for about 1,100 CFM and weighs 99 lb, seven pounds less than its PSC counterpart. Outdoors, the W5A5S30AKAWA arrives with 5.5 lb of R-454B and a 22 sq ft condenser coil. For a rooftop or remote pad, a 50 ft 3/4" x 3/8" copper line set matches the 3/4" suction and 3/8" liquid connections, and a R-454B refrigerant jug covers the added charge for longer runs. Want to understand the efficiency rating? Read our guide to SEER2 and the DOE efficiency standards.

Condensing Unit & Air Handler Features

W5A5S30AKAWA Outdoor Condensing Unit

  • 16 SEER2 when paired with the FMA5X3000AL fan coil
  • Single-stage scroll compressor with internal thermal overload
  • Six-circuit, 22 sq ft condenser coil
  • 5.5 lb factory R-454B charge
  • 3,300 CFM vertical-discharge condenser fan
  • 16.5 MCA; 25 amp maximum time-delay fuse or breaker
  • 71 dBA sound power rating, 69 dBA with sound shield
  • Operating voltage range of 197 to 253 volts
  • Up to 80 ft with the indoor unit above the condenser
  • 1-year unit replacement limited warranty and 10-year parts with registration

FMA5X3000AL Wall-Hung Fan Coil

  • 1/2 HP, 5-tap constant-torque ECM blower
  • Factory set on tap 2 for a nominal 1,100 CFM
  • 750 to 1,125 CFM minimum-to-maximum airflow range
  • 39-1/2" H x 22" W x 19" D cabinet, 99 lb shipping weight
  • 3.0 sq ft all-aluminum slope coil with TXV
  • Factory refrigerant leak detection system
  • Cabinet air leakage below 1.4% per ASHRAE 193
  • Equivalent airflow with front or bottom return
  • Accepts a common 20" x 20" x 1" field-supplied filter
  • Optional EHK205B, EHK208B, or EHK210B electric heat kit

Specifications & Manuals

Product documentation includes W5A5S condenser specifications and installation instructions, the Grandaire AC condenser brochure, and FMA5L/FMA5X fan coil specifications, installation, service, wiring, and warranty literature to assist with equipment selection, installation, and service.

Frequently Asked Questions

Which floor plans call for the 2.5 ton W5A5S30AKAWA / FMA5X3000AL system?

Two-bedroom, two-bath condos and smaller three-bedroom apartments, usually in the 1,200 to 1,500 square foot range, are the typical match. Extra glass, top-floor exposure, or a hot climate can push a smaller plan into this size, so confirm with a load calculation.

What separates the FMA5X3000AL from the 2 ton FMA5X2400AL?

The FMA5X3000AL moves into the larger 22" wide cabinet with a 3.0 sq ft coil, upgrades to a 1/2 HP ECM motor, and delivers about 1,100 CFM nominal versus 800 CFM. It also takes a 20" x 20" x 1" filter instead of the 15.5" x 19.5" size used on the 2 ton.

What subcooling target is used to charge the W5A5S30AKAWA?

With a TXV indoor coil like the one in the FMA5X3000AL, the W5A5S technical specifications list a required subcooling of 6°F for the size 30 condenser. Always follow the charging procedure in the installation instructions.

Does the FMA5X3000AL require return-air ductwork?

The FMA5 product data notes that no return-air ductwork is required in specific applications. Whether a ducted return is needed depends on the installation, so check the installation instructions and local code for your setup.

What electrical service does the W5A5S30AKAWA condenser need?

The W5A5S30AKAWA runs on 208/230V single-phase power with a minimum circuit ampacity of 16.5 amps and a 25 amp maximum time-delay fuse or breaker. The FMA5X3000AL air handler is wired separately at 208/230V single phase.

Who benefits most from a 2.5 ton ECM apartment system?

Owners of larger condos, property managers upgrading premium units, and anyone paying the electric bill for a family-sized apartment. Budget-focused buyers can compare the 2.5 ton PSC FMA5L3000AL system, and those wanting heat pump heating can look at the 2.5 ton EcoTemp FMA5X heat pump system.