5 Ton Gree Flexx Ultra 18.5 SEER2 R32 Inverter Heat Pump System FXU60HP230V1R32AO, FXU60HP230V1R32AH — Closeout Special
One unit left, and it is priced to move. This is the factory-matched all Flexx Ultra pairing: the FXU60HP230V1R32AO inverter condenser with the FXU60HP230V1R32AH multi-position ducted air handler, certified together at 18.5 SEER2 under AHRI 215213332. Sixty thousand BTU of R32 variable-capacity heating and cooling, a Gree G20 two-stage inverter compressor that modulates from 34,214 all the way up to 61,600 BTU/h, and heating operation down to -22°F. The two halves are sold together as a matched set only. List price on this package is $8,733. Our closeout price is $5,740, a $2,993 reduction, and when this one ships the listing comes down.
Why This Package Is a Closeout, and Who Should Grab It
Closeout pricing here has nothing to do with the condition or capability of the equipment. This is current-generation R32 inverter gear with a full factory warranty. Gree has simply moved the Flexx system pairings toward the FXU condenser and FXE Eco air handler combination, which means the all-Ultra FXU60/FXU60 match is being wound down. We are holding the last one, and rather than carry it we are letting it go at $2,993 under list.
Anyone sizing a large ducted job should look hard at this. The FXU60 outdoor unit modulates between 34,214 and 61,600 BTU/h in cooling and 25,931 to 57,240 BTU/h in heating, so it fits a calculated load anywhere from roughly 2.85 tons to a full 5 tons. It delivers 53,000 BTU/h at 95°F and still puts out 45,000 BTU/h at 17°F, with an HSPF2 of 10.5. The matched FXU60HP230V1R32AH air handler moves 1,500 CFM through a five speed centrifugal blower and pulls 9.76 pt/hr of moisture. Duct static is the thing to verify before you commit, because the cabinet is rated to a maximum 1.0 in. w.c. external static pressure.
Ideal for: A contractor with a large home, restaurant, retail suite, or church job on the board who can take delivery now and wants high-efficiency R32 inverter equipment at a price well under current production. Also a strong fit for anyone already running Flexx Ultra equipment who wants a matching system rather than a mixed pairing.
Once this one is gone: The equivalent current-production package is the 5 Ton Gree Flexx 18.5 SEER2 R32 System FXU60HP230V1R32AO, FXE60HP230V1R32AH, which uses the same outdoor unit with the Flexx Eco air handler. More discounted equipment is on our closeout equipment page.
Closeout pricing applies to the remaining unit only, is sold as a matched pair, and is not restocked at this price. Recommended applications are general guidelines only. Actual system requirements depend on insulation, duct design, ambient conditions, infiltration, internal gain, and a calculated heating and cooling load. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Condenser | FXU60HP230V1R32AO — 60,000 BTU Flexx Ultra Inverter Heat Pump Condenser |
|---|---|
| Indoor Air Handler | FXU60HP230V1R32AH Flexx Ultra Multi-Position Ducted Air Handler |
| Application | Large Residential and Light Commercial Ducted Split Heat Pump |
| Refrigerant | R32, factory charge 162.3 oz, 0.215 oz/ft additional |
| Compressor | Gree G20 Double Cylinder Two-Stage Inverter |
| Rated Efficiency | 18.5 SEER2, 11.7 EER2, 10.5 HSPF2 — AHRI 215213332 |
| Electrical | Condenser 208-230V, Single Phase, 60 Hz — MCA 39.9A, MOCP 45A |
| Air Handler Electrical | 208-230V, Single Phase, 60 Hz — MCA 7.7A, MOCP 15A, 24 VAC control |
| Warranty | 5 Year Standard, 10 Year With Gree Authorized Dealer Registration Within 30 Days |
Both halves ship as a factory-certified match, which is what the AHRI 215213332 rating is tied to, and on this closeout they are only available together. The FXU60 condenser is a narrow side-discharge cabinet at 35-7/16 in. wide by 49-5/8 in. high and only 13-3/8 in. deep, 241.4 lb net, with a gold fin coil rated to 1,500 hours salt spray. The FXU60 air handler measures 24-13/16 in. wide by 52 in. high by 21-1/4 in. deep at 199.5 lb, carries a blue fin coil at 500 hours salt spray, and installs upflow, downflow, or horizontal. Line set is 3/8 in. liquid by 3/4 in. gas flared, precharged for 31 ft, rated from 10 to 98 ft with up to 49 ft of elevation difference. Everything runs on standard 24 VAC control, so no proprietary communicating thermostat is required.
Condenser & Air Handler Features
FXU60HP230V1R32AO Outdoor Condenser
- Gree G20 double cylinder two-stage inverter compressor
- Cooling modulation 34,214 to 61,600 BTU/h
- Heating modulation 25,931 to 57,240 BTU/h
- 53,000 BTU/h cooling at 95°F, 54,000 BTU/h heating at 47°F
- 45,000 BTU/h heating still available at 17°F, COP 2.10 at 5°F
- Heating to -22°F, cooling from 5°F to 129°F
- Zero lot line cabinet only 13-3/8 in. deep with side discharge
- Gold fin anti-corrosion coil, 1,500 hour salt spray rating
- Rated current 31A cooling, 32A heating; MCA 39.9A, MOCP 45A
- 63 dB(A) sound pressure level, 241.4 lb net weight
FXU60HP230V1R32AH Flexx Ultra Air Handler
- Factory-matched Ultra cabinet, AHRI certified with the FXU60 condenser
- 1,500 CFM rated airflow
- Five speed centrifugal blower with published curves to 1.0 in. w.c.
- Multi-position: upflow, downflow, or horizontal
- 9.76 pt/hr dehumidification capacity
- Copper tube, aluminum fin coil with blue anti-corrosion coating, 500 hour salt spray
- Field-installed electric heat kits from 5 kW to 20 kW
- Factory filter included
- MCA 7.7A, MOCP 15A on 24 VAC control
- 53 dB(A) sound pressure level, 199.5 lb net weight
Specifications & Manuals
Product documentation includes 60,000 BTU submittal data for the FXU60 matched pair, outdoor condenser and indoor air handler installation information, quick start instructions, Flexx R32 series literature, and warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
Why is this Gree Flexx Ultra system a closeout?
Gree has shifted the Flexx system lineup toward pairing the FXU outdoor unit with the FXE Eco air handler, so the all-Ultra FXU60/FXU60 match is winding down. The equipment is new, current-generation R32 inverter gear with full factory warranty. The reduced price reflects our remaining inventory position, not the condition or capability of the system.
Can I buy just the condenser or just the air handler at this price?
No. This is the final matched pair and it is sold as a complete system only. Splitting it would leave an orphaned half that cannot be AHRI matched or sold at this price. The closeout applies to the two units together.
Does the closeout price change the Gree warranty?
No. This package carries the standard 5 year warranty out of the box with no registration required, and that extends to 10 years when a Gree Authorized Dealer registers the system within 30 days of installation. Registration requires the installer's invoice. Closeout pricing has no effect on either term.
How does the FXU60/FXU60 pairing differ from the FXU60/FXE60 system?
Both use the identical FXU60HP230V1R32AO outdoor unit, so compressor performance and operating range are the same. The difference is indoors. This package uses the Flexx Ultra FXU60HP230V1R32AH air handler, AHRI certified as 215213332, which is rated at 9.76 pt/hr dehumidification and 53 dB(A). The Eco version is certified as 217123259 at 9.56 pt/hr and 54 dB(A). Both move 1,500 CFM.
What electrical service does this 5 ton Flexx Ultra system require?
Both units run on 208-230V single phase 60 Hz. The condenser has an MCA of 39.9A with a maximum overcurrent protection of 45A, drawing 31A rated in cooling and 32A in heating. The air handler is on its own circuit at 7.7A MCA with 15A MOCP before any electric heat kit. Adding a heat kit raises the indoor circuit substantially, so size the feeder from the submittal table for the kit you select.
How much airflow and static pressure can the FXU60HP230V1R32AH handle?
Rated airflow is 1,500 CFM with a maximum external static pressure of 1.0 in. w.c. The five speed blower has published fan curves; at top speed it still delivers 1,890 CFM against a full 1.0 in. w.c. Undersized returns, restrictive filter racks, and long flex runs will cost capacity before the equipment does, so confirm duct static during commissioning.
Click On Below Link(s) For Documentation:
Technical Specifications
Outdoor Condenser Installation Manual
Indoor Air Handler Installation Manual