decor decor

Summary

Product #179433: $3,750.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Indoor Air Quality:
  • Thermostats:
  • 42018 / 4 Ton Goodman R32 Heat Pump Condenser GLZS4BA481 (179394) -- 1
  • 42024 / 4 Ton Goodman R32 Air Handler AMST48CU1300 (179400) -- 1
3750
$3,750.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GLZS4BA4810, AMST48CU1300 | 4 Ton Heat Pump with Copper-Tube Coil for Larger Homes

4 Ton Goodman 15.2 SEER2 R32 Heat Pump System GLZS4BA4810, AMST48CU1300

· SKU 179433 · AHRI 215213861 · Split System
SEER2
15.2
Capacity
48,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $6,329.00

Our price:

$5,673.00

Sale price:

$3,750.00
You save $2,579.00!

Click For Sale Price

Sale price:

$3,750.00

List price:

$6,329.00

Our price:

$5,673.00
You save: 34% ($2,579.00)
  • SKU: 179433
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    15.2
  • Product Type:
    Split System
  • Tonnage:
    4
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    21"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • 19kW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-19CB / HKTSD19CB  /WKS2002B
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 1 1/8 & 3/8
  • Copper Line Set 50' 1 1/8 & 3/8
  • Clean Comfort 1" Electronic Cleaner 19.5x20 model AE10-1920-14
  • Clean Comfort Electronic Air Cleaner model AE14-2020-51
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • 4 Ton Goodman 14.3 SEER2 R32 Heat Pump Condenser GLZS4BA4810
  • 4 Ton Goodman R32 Air Handler AMST48CU1300
Adding to cart… The item has been added

4 Ton Goodman 15.2 SEER2 R32 Heat Pump System GLZS4BA4810, AMST48CU1300

This 4 ton Goodman split system combines the GLZS4BA4810 outdoor heat pump, built with an enhanced aluminum fin coil on 7 mm copper tubes, and the AMST48CU1300 air handler with a wider 10" x 10" blower. Together they provide 48,000 BTU/h of R-32 heating and cooling at 15.2 SEER2 under AHRI #215213861, serving larger homes, multi-story houses, and high-load spaces that need strong airflow and dependable year-round capacity.

Is a 4 Ton Heat Pump System the Right Size?

A 48,000 BTU/h heat pump is meant for substantial loads: larger two-story homes, houses with high ceilings or extensive glass, and homes in hot climates with long cooling seasons. It is also a common replacement size for older 4 ton systems in established neighborhoods.

At this capacity, airflow is the make-or-break factor. A 4 ton system needs properly sized supply and return ducts to deliver its rated performance without whistling registers or a noisy return. Insulation, climate, and how the home is used still drive the load, so confirm with a calculation before choosing between 3.5, 4, and 5 tons.

Ideal for: Larger two-story homes, homes with vaulted ceilings or lots of glass, hot-climate homes with long cooling seasons, and replacement of an existing 4 ton heat pump.

Need more capacity? Step up to the 5 Ton Goodman 14.5 SEER2 R32 Heat Pump System GLZS4BA6010, AMST60DU1300, the largest system in this series.

Recommended system sizes are general guidelines only. Actual heating and cooling requirements depend on insulation, climate, windows, ductwork, ceiling height, and occupancy. A Manual J load calculation is the best way to confirm sizing. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump GLZS4BA4810 — 4 Ton R-32 Single-Stage Heat Pump Condenser
Indoor Air Handler AMST48CU1300 — 4 Ton Multi-Position ECM Air Handler with Internal TXV
System Rating 15.2 SEER2, 48,000 BTU/h Nominal, AHRI #215213861
Refrigerant R-32
Compressor Single-Stage Scroll Compressor
Defrost SmartShift® Defrost Technology
Electrical 208/230V, Single Phase, 60 Hz Heat Pump — MCA 25.5 A, Max Breaker 40 A
Air Handler Electrical 208/240V, Single Phase — 3/4 HP ECM Blower, 21" C Cabinet

The AMST48CU1300 is the tallest C-cabinet model at 58", so measure closet height before ordering. It uses a 7/8" suction coil connection and a 10" x 10" blower to move the extra air a 4 ton system needs. Outdoors, plan for a 1-1/8" x 3/8" copper line set, a 40 A maximum breaker, and a sturdy condenser pad for the 269 lb unit.

Heat Pump & Air Handler Features

GLZS4BA4810 Outdoor Heat Pump

  • 48,000 BTU/h nominal heating and cooling
  • Enhanced aluminum fin coil with 7 mm copper tubes
  • Single-stage scroll compressor (19.4 RLA)
  • 1/4 HP PSC condenser fan motor
  • SmartShift® defrost technology
  • 174 oz factory R-32 charge for 15 feet of line
  • Factory-installed crankcase heater and high-capacity muffler
  • 35-1/2" W x 35-1/2" D x 36-1/2" H cabinet, 269 lbs
  • Removable grille-style top for service access
  • AHRI Certified and ETL Listed

AMST48CU1300 Multi-Position Air Handler

  • 4 ton rating with a 10" x 10" blower assembly
  • 3/4 HP direct-drive multi-speed ECM motor
  • 7/8" suction and 3/8" liquid coil connections
  • Factory-installed TXV and R-32 refrigerant sensor
  • 21" C-width cabinet, 58" tall
  • Horizontal or vertical configuration
  • Cabinet air leakage under 2.0% at 1.0" H2O (ASHRAE 193)
  • DecaBDE-free drain pan with secondary drain connections
  • Tool-less access for a 19.5" x 20" filter
  • Heat strip options up to 19 kW breakered on this listing

Specifications & Manuals

Documentation includes 4 ton capacity and electrical data, expanded heating tables for cold-weather planning, AMST48CU1300 dimensions and airflow, plus installation and warranty details.

Frequently Asked Questions

When is a 4 ton GLZS4BA4810 heat pump system the right choice?

It is the right size when a load calculation shows roughly 48,000 BTU/h, which is common in larger two-story homes, homes with high ceilings, and hot climates with long cooling seasons.

What makes the GLZS4BA4810 coil different from smaller GLZS4B models?

Goodman builds the 4 and 5 ton models with an enhanced aluminum fin coil on 7 mm copper tubes, while the 1.5 to 3.5 ton models use 5 mm tubes.

What electrical service does the 4 ton GLZS4BA4810 need?

Goodman lists a 25.5 A minimum circuit ampacity and a 40 A maximum overcurrent protection on 208/230V single phase. The air handler and heat strip need their own circuit.

How tall is the AMST48CU1300 air handler?

Per Goodman's dimension table, the AMST48CU1300 is 58" tall in a 21" C-width cabinet. Check closet height and clearances before installation.

Does the AMST48CU1300 use a larger blower than the 3.5 ton air handler?

Yes. It uses a 10" x 10" blower, compared with 10" x 8" on the AMST42CU1300. Both use a 3/4 HP ECM motor.

Can I pair a 4 ton heat pump with gas backup heat instead of heat strips?

This system is designed for electric heat strip backup. If you prefer gas backup, see our dual fuel heat pump systems.

Customer Review