3 Ton Goodman 14.8 SEER2 R32 Heat Pump System GLZS5BA3610, AMST36BU1300
This Goodman 3 ton heat pump system pairs the GLZS5BA3610 R-32 outdoor unit with the space-saving AMST36BU1300 air handler, built in Goodman's slim 17.5" B cabinet. The AHRI-certified match (AHRI #218217336) is rated at 14.8 SEER2. It's the practical choice when a 3 ton heat pump has to fit an existing narrow closet or tight attic space. Homeowners and contractors get 36,000 BTU/h nominal heating and cooling without enlarging the air handler opening.
Is a 3 Ton Heat Pump System the Right Size?
This version gives you 3 tons of nominal capacity in a smaller indoor footprint. It suits homes where the load calls for 3 tons but the air handler location limits cabinet width. If space isn't a constraint, Goodman's 15.2 SEER2 match with the larger AMST42CU1300 offers higher efficiency.
Confirm sizing with a load calculation that accounts for insulation, glass, ceiling height, and climate. Also check that your ductwork can support about 3 tons of airflow. The AMST36BU1300's highest speed tap is published at about 1,070 CFM at 0.5 in. w.c.
Ideal for: Three- to four-bedroom homes with narrow utility closets, tight attic platforms, or replacements where the existing air handler opening is about 17.5" wide.
Need more capacity? Step up to the 3.5 Ton Goodman 15.2 SEER2 R32 Heat Pump System GLZS5BA4210, AMST42CU1300, or choose the 3 Ton 15.2 SEER2 GLZS5BA3610, AMST42CU1300 system for higher efficiency at the same tonnage.
Recommended sizing is a general guideline only. Actual system requirements depend on insulation, climate, ductwork, windows, occupancy, and home layout. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.
What's Included
| Outdoor Heat Pump | GLZS5BA3610 — 3 Ton R-32 Heat Pump |
|---|---|
| Indoor Air Handler | AMST36BU1300 Multi-Position ECM Air Handler (B Cabinet) |
| Application | Residential Split System Heat Pump (Heating & Cooling) |
| Refrigerant | R-32 |
| Compressor | Single-Stage Scroll Compressor |
| Efficiency | 14.8 SEER2 — AHRI #218217336 |
| Electrical | 208/230V, Single Phase, 60 Hz Outdoor Unit |
| Air Handler Electrical | 208/240V, Single Phase, 60 Hz |
The GLZS5BA3610 is the first size in the GLZS5B line to use a 7/8" suction line, and matching 7/8" x 3/8" insulated line sets are available. The AMST36BU1300 combines a factory TXV, a 3/4 HP multi-speed ECM blower, and an all-aluminum coil in a 53-7/16" tall, 17.5" wide cabinet. Heat strips up to 15 kW are optional. Explore more Goodman HVAC systems.
Heat Pump & Air Handler Features
GLZS5BA3610 Outdoor Heat Pump
- 36,000 BTU/h nominal heating and cooling
- Scroll compressor (16.4 RLA / 88 LRA)
- SmartShift quiet defrost
- 35-1/2" W x 35-1/2" D x 39-1/2" H cabinet
- 3/8" liquid and 7/8" suction line sizes
- 21.5 A MCA, 35 A max overcurrent protection
- Charged for 15' of 3/8" liquid line
- Removable grille-style top compliant with UL 60335-2-40
- Heavy-gauge galvanized-steel cabinet
- Anchor bracket kit available for hurricane-code installs
AMST36BU1300 Air Handler
- Slim 17.5" wide B cabinet, 53-7/16" tall
- 3/4 HP multi-speed ECM blower, 10" x 6" wheel
- Factory-installed TXV
- All-aluminum evaporator coil
- Factory-installed R-32 sensor
- Horizontal or vertical installation
- 5.6 A MCA, 15 A max overcurrent (without heat strip)
- 3/4" FPT condensate drain connections
- Tool-less filter access
- Heat strip options: 5, 8, 10, or 15 kW
Specifications & Manuals
Product documentation includes outdoor heat pump and air handler technical specifications, installation instructions, and Goodman warranty information to assist with equipment selection, installation, and service.
Frequently Asked Questions
Why choose the AMST36BU1300 version of the 3 ton system?
It uses Goodman's narrower 17.5" B cabinet. That helps when a 3 ton heat pump has to fit an existing closet or attic opening that can't take the 21" C cabinet.
How does this 3 ton system compare with the 15.2 SEER2 AMST42CU1300 match?
Both use the same GLZS5BA3610 outdoor unit. The AMST42CU1300 match is rated higher at 15.2 SEER2 with a larger 21" cabinet, while this AMST36BU1300 match is rated 14.8 SEER2 in a slimmer cabinet.
What suction line size does the GLZS5BA3610 require?
Goodman specifies a 3/8" liquid line and a 7/8" suction line for the 3 ton model. Insulated 7/8" x 3/8" line sets in 25' and 50' lengths are offered.
What is the largest heat strip for the AMST36BU1300?
The options for this system go up to a 15 kW breakered heat strip. Goodman's heat kit data for the AMST36BU lists kits up to the HKTSD15 two-circuit model.
Does Goodman's warranty cover rental properties?
The GLSX/GLZS limited warranty applies to owner-occupied residences. Goodman states different warranties apply to non-owner-occupied residences and commercial properties. See the warranty certificate for details.
What is the electrical requirement for the GLZS5BA3610?
Goodman lists 208/230V single-phase power with a 21.5 A minimum circuit ampacity and 35 A maximum overcurrent protection. Use a time-delay fuse or HACR breaker and confirm against the rating plate.
"SEER2" stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).