decor decor

Summary

Product #179844: $3,865.00
  • Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info :
  • Heat Strip:
  • Copper Line Set or Flush Kit:
  • Thermostats:
  • 46070 / 3 Ton Goodman R32 Heat Pump Condenser GLZS5BA3610 (179834) -- 1
  • 46128 / 2.5-3 Ton Goodman R32 Air Handler AMST36BU1300 (179867) -- 1
3865
$3,865.00
Can't Decide? We can Help
Custom Quote
Have a large order? Need more customization?
GLZS5BA3610, AMST36BU1300 | Full 3 Ton Heat Pump Power in a Closet-Friendly B Cabinet

3 Ton Goodman 14.8 SEER2 R32 Heat Pump System GLZS5BA3610, AMST36BU1300

· SKU 179844 · AHRI 218217336 · Split System
SEER2
14.8
Capacity
36,000 BTU
Refrigerant
R-32

Understanding SEER2 Ratings: Learn how SEER2 is measured and the minimum efficiency your home needs »

Not Sure What Size System You Need? Sizing Calculator »

Average Rating:
List price: $6,280.00

Our price:

$5,513.00

Sale price:

$3,865.00
You save $2,415.00!

Click For Sale Price

Sale price:

$3,865.00

List price:

$6,280.00

Our price:

$5,513.00
You save: 30% ($2,415.00)
  • SKU: 179844
  • Availability:
    Usually Ships in 2 to 3 Business Days
  • Shipping:
    Calculated at Checkout
  • AHRI Certificate:
  • AHRI Number:
  • SEER2:
    14.8
  • Product Type:
    Split System
  • Tonnage:
    3
  • Operating Mode:
    Heat Pump
  • Refrigerant Type:
    R-32
  • Cabinet Width:
    17.5"
  • Manufacturer Warranty:
    10 Years
Fast Track - Ships Next business Day **Some Restrictions Apply** Click '?' For More Info ?
  • 5 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSX-05 / HKTSN05X1 / WKS0502
  • 8 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-08 / HKTSN08X1 / WKS0802
  • 10 KW heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC HKSX-10 / HKTSN10X1 / WKS1002
  • 15 KW breakered heat strip for Goodman/Amana AMST,AMVT,AMVE,ARUF, AVPTC,AVPEC,ARPT, ASPT, ASUF, AUPTC  HKSC-15XB / HKTSD15XB /WKS1502B
  • Easy One-Step Ultra Flush Kit with Reusable Hose Nozzle (up to 5 tons)
  • Copper Line Set 25' 7/8 & 3/8
  • Copper Line Set 50' 7/8 & 3/8
  • TempĕSure Thermostat 2H/2C Digital Non-Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat TESD22
  • TempĕSure Thermostat 2H/2C Digital Programmable Straight Cool, Heat Pump, Electric Heat, Gas Heat Compatible with 5ft Remote Sensor TESPR22
  • Honeywell T6 Pro Thermostat 2H/1C Programmable TH6210U2001
  • Honeywell Pro 8000 Wi-Fi Touchscreen Thermostat 3H/2C Programmable TH8321WF1001
  • Nest 4th Generation PRO Learning Thermostat 3H/2C, with Nest Temperature Sensor (2nd gen) GA05560-US
  • Ecobee 3H/2C Touchscreen Smart WiFi Programmable Thermostat EB-STATE6LP-01
  • 3 Ton Goodman 15.2 SEER2 R32 Heat Pump Condenser GLZS5BA3610
  • 2.5-3 Ton Goodman R32 Air Handler AMST36BU1300
Adding to cart… The item has been added

3 Ton Goodman 14.8 SEER2 R32 Heat Pump System GLZS5BA3610, AMST36BU1300

This Goodman 3 ton heat pump system pairs the GLZS5BA3610 R-32 outdoor unit with the space-saving AMST36BU1300 air handler, built in Goodman's slim 17.5" B cabinet. The AHRI-certified match (AHRI #218217336) is rated at 14.8 SEER2. It's the practical choice when a 3 ton heat pump has to fit an existing narrow closet or tight attic space. Homeowners and contractors get 36,000 BTU/h nominal heating and cooling without enlarging the air handler opening.

Is a 3 Ton Heat Pump System the Right Size?

This version gives you 3 tons of nominal capacity in a smaller indoor footprint. It suits homes where the load calls for 3 tons but the air handler location limits cabinet width. If space isn't a constraint, Goodman's 15.2 SEER2 match with the larger AMST42CU1300 offers higher efficiency.

Confirm sizing with a load calculation that accounts for insulation, glass, ceiling height, and climate. Also check that your ductwork can support about 3 tons of airflow. The AMST36BU1300's highest speed tap is published at about 1,070 CFM at 0.5 in. w.c.

Ideal for: Three- to four-bedroom homes with narrow utility closets, tight attic platforms, or replacements where the existing air handler opening is about 17.5" wide.

Need more capacity? Step up to the 3.5 Ton Goodman 15.2 SEER2 R32 Heat Pump System GLZS5BA4210, AMST42CU1300, or choose the 3 Ton 15.2 SEER2 GLZS5BA3610, AMST42CU1300 system for higher efficiency at the same tonnage.

Recommended sizing is a general guideline only. Actual system requirements depend on insulation, climate, ductwork, windows, occupancy, and home layout. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What's Included

Outdoor Heat Pump GLZS5BA3610 — 3 Ton R-32 Heat Pump
Indoor Air Handler AMST36BU1300 Multi-Position ECM Air Handler (B Cabinet)
Application Residential Split System Heat Pump (Heating & Cooling)
Refrigerant R-32
Compressor Single-Stage Scroll Compressor
Efficiency 14.8 SEER2 — AHRI #218217336
Electrical 208/230V, Single Phase, 60 Hz Outdoor Unit
Air Handler Electrical 208/240V, Single Phase, 60 Hz

The GLZS5BA3610 is the first size in the GLZS5B line to use a 7/8" suction line, and matching 7/8" x 3/8" insulated line sets are available. The AMST36BU1300 combines a factory TXV, a 3/4 HP multi-speed ECM blower, and an all-aluminum coil in a 53-7/16" tall, 17.5" wide cabinet. Heat strips up to 15 kW are optional. Explore more Goodman HVAC systems.

Heat Pump & Air Handler Features

GLZS5BA3610 Outdoor Heat Pump

  • 36,000 BTU/h nominal heating and cooling
  • Scroll compressor (16.4 RLA / 88 LRA)
  • SmartShift quiet defrost
  • 35-1/2" W x 35-1/2" D x 39-1/2" H cabinet
  • 3/8" liquid and 7/8" suction line sizes
  • 21.5 A MCA, 35 A max overcurrent protection
  • Charged for 15' of 3/8" liquid line
  • Removable grille-style top compliant with UL 60335-2-40
  • Heavy-gauge galvanized-steel cabinet
  • Anchor bracket kit available for hurricane-code installs

AMST36BU1300 Air Handler

  • Slim 17.5" wide B cabinet, 53-7/16" tall
  • 3/4 HP multi-speed ECM blower, 10" x 6" wheel
  • Factory-installed TXV
  • All-aluminum evaporator coil
  • Factory-installed R-32 sensor
  • Horizontal or vertical installation
  • 5.6 A MCA, 15 A max overcurrent (without heat strip)
  • 3/4" FPT condensate drain connections
  • Tool-less filter access
  • Heat strip options: 5, 8, 10, or 15 kW

Specifications & Manuals

Product documentation includes outdoor heat pump and air handler technical specifications, installation instructions, and Goodman warranty information to assist with equipment selection, installation, and service.

Frequently Asked Questions

Why choose the AMST36BU1300 version of the 3 ton system?

It uses Goodman's narrower 17.5" B cabinet. That helps when a 3 ton heat pump has to fit an existing closet or attic opening that can't take the 21" C cabinet.

How does this 3 ton system compare with the 15.2 SEER2 AMST42CU1300 match?

Both use the same GLZS5BA3610 outdoor unit. The AMST42CU1300 match is rated higher at 15.2 SEER2 with a larger 21" cabinet, while this AMST36BU1300 match is rated 14.8 SEER2 in a slimmer cabinet.

What suction line size does the GLZS5BA3610 require?

Goodman specifies a 3/8" liquid line and a 7/8" suction line for the 3 ton model. Insulated 7/8" x 3/8" line sets in 25' and 50' lengths are offered.

What is the largest heat strip for the AMST36BU1300?

The options for this system go up to a 15 kW breakered heat strip. Goodman's heat kit data for the AMST36BU lists kits up to the HKTSD15 two-circuit model.

Does Goodman's warranty cover rental properties?

The GLSX/GLZS limited warranty applies to owner-occupied residences. Goodman states different warranties apply to non-owner-occupied residences and commercial properties. See the warranty certificate for details.

What is the electrical requirement for the GLZS5BA3610?

Goodman lists 208/230V single-phase power with a 21.5 A minimum circuit ampacity and 35 A maximum overcurrent protection. Use a time-delay fuse or HACR breaker and confirm against the rating plate.

SEER2 Explained

"SEER2" stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).

Customer Review